Range of overhead shower outlets with chromium plated plastic bodies. Models SD1062 and SD1064 incorporate stainless steel strainers in the inlets. Maximum working temperature 75°C.
A self-closing shower handset with a plastic body, the inlet incorporates a plastic flow restrictor and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 85 °C.
Range of shower handsets with chromium plated plastic bodies. Maximum operating temperature 75°C.
Shower handset incorporating a chromium plated plastic body. Maximum operating temperature 65°C.
Shower handset (various finishes) with built in flow restrictor. Maximum operating temperature 60°C.
Shower hose incorporating an EPDM liner and grey PET outer layer. Supplied with EPDM washers. Maximum operating temperature 70°C.
Range of shower handsets with a chrome plated body. Maximum operating temperature 60°C.
PVC lined, chrome plated shower hose. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies. Models P60901 and P61400 have check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of pillar taps (chrome plated brass) with non-rising spindle headworks and cross type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrome plated brass) incorporating non-rising spindle headwork with cross type operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 7.0 bar. Maximum operating temperature 60°C.
Range of stainless steel braided PE-X lined flexible hose assemblies incorporating NBR washers and various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided EPDM lined hose assemblies with EPDM O-rings and some models incorporate a servicing valve. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. The storage cylinders incorporate an internal air bubble to accommodate the expansion of hot water. The DHW circuit has a factory fitted temperature and pressure relief valve set at 10.0@90˚C. The inlet control group includes a pressure reducing valve set at 3.0 bar, single check valve cartridge (verified by test and suitable for backflow protection against Fluid Category 2) and a expansion valve set at 8.0 bar. The products are supplied with a tundish and a motorised valve to be installed on the primary indirect circuit. Maximum supply pressure to the pressure reducing valve is 12.0 bar. Maximum working pressure of primary circuit is 6.0 bar. Maximum secondary circuit is 9.5 bar. Maximum operating temperature 85°C.
Range of wall mounted manually operated, concealed blending valves (brass body) incorporating ceramic cartridge headworks with single lever operating members and a manual diverter to shower outlets with single lever operating members. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, flow control valves with brass bodies and various trim sets (various finishes). Flow is controlled to the outlets via a push to on push to off ‘detent’ headwork. Maximum Working Pressure 10.0 bar. Maximum operating temperature 70°C.
Range of wall mounted bar type thermostatic shower mixers (chromium plated brass) incorporating a ceramic disc headworks controlling the flow. Temperature is controlled via a thermostatic cartridge with single lever type operating members which incorporate manual override buttons. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge; however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Products are supplied with a shower hose, shower handset, riser rail and soap dish. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, concealed, thermostatic shower valve with brass body, incorporating half turn ceramic disc headworks controlling and diverting the flow, the temperature is controlled independently via a thermostatic cartridge, with dome type operating members. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge; however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Products are supplied with a shower hose, shower handset, riser rail and overhead shower. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Wall mounted, concealed, thermostatic shower valve with brass body. Incorporating a quarter turn ceramic disc headwork which controls the flow, temperature is controlled independently via a thermostatic cartridge with cube type operating members. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge; however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Products are supplied with a shower hose, shower handset and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Wall mounted, concealed, thermostatic shower valve with brass body, incorporating half turn ceramic disc headworks controlling and diverting the flow, the temperature is controlled independently via a thermostatic cartridge, with single lever operating members. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge; however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Products are supplied with a shower hose, shower handset, riser rail and overhead shower. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Page 25 of 584
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.