Range of Talbot pushfit fittings with polyprolylene or acetal bodies and EPDM o-rings for use with MDPE PE80 pipe (BS EN 12201). For use above and below ground use. Maximum working pressure 16 bar. Cold water use only.
‘DELBRAZE’ range of copper and copper alloy braze fittings for use with copper pipe (EN1057). Maximum working pressure: 16 bar. Maximum working temperature: 85°C.
Single flush WC outlet valves with an ABS plastic body (WC01), operated via a mains powered infra red sensor assembly (WC03). Cold water use only.
Range of syphonic flush valves with plastic bodies. Cold water only
WC dual flush valve with a plastic body, operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Maximum operating temperature – Cold water use only.
Range of manually operated and sensor operated dual flush WC outlet valves. Cold water use only.
Range of WC dual flush drop valves with ABS bodies and silicone seals. The valves are operated via a two push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.
Range of plate heat exchangers with stainless steel plate bodies and copper brazing. Maximum working pressure: 45 Bar. Maximum operating temperature: 99 °C.
‘MJ-SDC plus’ range of water meters with brass bodies, incorporating plastic impellers. The inlets incorporate plastic filters. Maximum working pressure 16 Bar. Maximum operating temperature 50°C.
‘Wesan WP’ range of water meters with black epoxy coated cast iron bodies, plastic impellers and EPDM ‘O’-rings and seal. Maximum working pressure 16.0 bar. Cold water use only.
Range of ultrasonic in-line water meters with brass bodies, inlets incorporating plastic strainers. Model (MA408 – DN25) incorporates a non-return valve (not suitable for backflow prevention) at the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with brass or DZR brass bodies. The outlets incorporate non-return valves (not suitable for backflow protection). For use with copper pipe manufactured to BS EN 1057 (WBBADAPT112). Maximum working pressure 10.0 bar. Cold water use only.
Range of (below ground) water meter manifolds (gunmetal bodies), meter carriers (DZR brass bodies) and stopcock carriers (gunmetal bodies). All meter carriers incorporate a non-return valve. All manifold ports and the stopcock carriers incorporate a non-rising spindle stopcock with a T shaped operating member. Maximum working pressure: 16.0°C Cold water use only.
Threaded adapter with plastic body. Maximum working pressure 12.5 bar. Cold water use only.
Isolation valve, stainless-steel braided EPDM lined flexible hose assembly and a non-verifiable double check valve assembly, verified by test (suitable for backflow protection against fluid category 3). For use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of vertical multistage pumps with either stainless-steel bodies or cast-iron bodies with a black epoxy powder coating, stainless-steel impellers, shaft and outer sleeve, EPDM ‘O’-rings and a silicon carbide + EPDM shaft seal. Maximum working pressure 25.0 bar. Maximum operating temperature 90°C.
Range of cold water supply booster sets, incorporating stainless steel manifold system connecting 2 or 3 wholesome water pumps. The set also includes spherical valves, non-return valves (not intended or suitable for backflow protection) and expansion vessels. Maximum working pressure 10.0 bar. Cold water supply only.
Range of shower handsets with chrome plated bodies. Open outlet use only Maximum operating temperature 85°C
Wall mounted shower kit comprising of shower hose, handset, overhead shower and a riser rail assembly incorporating a shower to shower diverter valve, (available in various finishes).
Non-metallic materials and components comply with BS6920 at 65°C
Page 236 of 521
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.