Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
A range of single-hole, single outlet, (swivel) combination tap assemblies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Models 71554XXX and 71564XXX are supplied with pop-up wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, two hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating ceramic disk headwork and dome type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, deck mounted, single outlet (fixed) electronically controlled combination tap assemblies with brass bodies (various finishes), flow is controlled by a solenoid valve activated via an infra-red sensor. Some models have a pre set temperature.. Inlets incorporate stainless steel strainers and single check valve cartirdges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of two hole, wall mounted single outlet (fixed) electronically controlled combination tap assemblies with brass bodies (various finishes), flow is controlled by a solenoid valve activated via an infra-red sensor. Some models have a pre set temperature. Inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of two hole, single outlet (fixed) combination tap assemblies incorporating brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. The spout outlet incorporates a plastic flow straightener. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass) incorporating a ceramic cartridge headwork and a single lever operating member. The tap body and spout oulet are connected via a stainless steel braided EPDM lined flexible hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed), combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass). The flow is controlled via non-rising spindle headworks with cross top operating members and a manually operated diverter to shower outlet. Supplied with hose and handset. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, (swivel) combination tap assemblies (chrome plated brass) incorporating a ceramic cartridge headwork with single lever type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass body with various finishes) incorporating quarter turn ceramic disc headworks with cross top type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes, see model). Incorporating a ceramic cartridge headwork with single lever operating member and a self-cancelling diverter, diverting the flow between the shower outlet and the bath outlet. The spout outlet incorporates a flow straightener and Incorporates approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also supplied with shower handset and hose. Handset incorporates a flow regulator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating quarter turn ceramic disc headworks with single lever or cross top operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. The products are supplied with a shower hose and the hose connector incorporates approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Not supplied with a shower handset. Maximum working pressure 5.0 bar Maximum operating temperature 60°C
Ranges of combined bath filler and overflow waste assembly incorporating a cable operated pop-up waste. Maximum operating temperature 65°C.
Range of combined bath fillers and overflow waste assemblies with plastic bodies (various finishes). The outlet incorporates a plastic aerator and the product is supplied with a cable operated pop-up waste. Maximum operating temperature 60°C.
Bath spout with brass body (chromium plated). The outlet incorporates a plastic aerator. Maximum operating temperature 60°C.
Range of free-standing sanitary macerating disposal units. The units are fed via a flexible hose assembly. Flow is controlled by a solenoid valve and discharges via a type `AA` air gap. Maximum working pressure 10.0 bar. Cold water use only.
Range of chemical dosing equipment which incorporate self-closing valves with a plastic body. The outlet of the injector incorporates a connection for injection of chemicals via venturi action. Maximum working pressure 9.0 bar. Maximum operating temperature – 60ºC
Easyzon range of chemical blenders, consisting of a reaction chamber and pressure reducing valve inlet arrangement only. Maximum working pressure 8.0 bar. Cold water use only.
FloFit range of push fit fittings (polybutylene body) for use with Qual-Pex Barrier Pipe, Qual-PB polybutylene barrier pipe or copper tube. Above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
‘Maincor’ range of pipe adaptors and ‘Multi-Fit’ straight connectors (brass bodies) for use with ‘Maincor PERT/Al/PERT MLC’ pipe. 12mm pipe and fittings have a maximum working pressure of 6.0 bar. 16mm & 20mm pipe and fittings have a maximum working pressure of 10.0 bar Maximum operating temperature 95°C
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
‘Epsilon Series’ polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Dual flush, WC outlet valves. Model A2706 is operated via a push button assembly for either full or reduced flush. Models A2415L & A2415M are not supplied with a operating button. Maximum operating temperature. Cold water use only.
Range of dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush. Cold water use only
Range of waste water heat recovery systems incorporating a twin wall copper coil (iZi models) or stainless steel (PiPe models). Maximum working pressure 10.0 bar. Cold water use only.
Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.
Digital water meter with brass body incorporating a plastic strainer on the inlet and a non-return valve (not suitable for backflow protection) on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve and a non-return valve (not suitable for back flow protection). Model MD1010101BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
Range of water meter manifolds with a plastic body and a spherical valve at the inlet. Models MB2012525DM & MB2010303DM incorporates two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection Model MB201010BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
`Groundbreaker Mk3` water meter box incorporating a concentric water meter manifold (plastic body) with screw down stop valve, single check valve (verified by test as suitable for backflow prevention up to fluid category 2) & compression fittings. The product is intended to be installed upon the external wall of a premises and incorporates internal insulation (insulation not verified by test). For use with MDPE pipe (manufactured to EN12201). Maximum working pressure 12.0 bar. Cold water use only.
Range of flow sensors with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C
Range of wall mounted shower arms and shower handsets with brass bodies (various finishes), the inlets to the shower handsets incorporating a flow restrictor. Maximum operating temperature 60°C.
Thermostatic element with copper shell, polyethylene tube and PTFE gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of threaded fittings with either plain brass, nickel plated brass or chrome plated brass bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 99°C.
Range of inline circulating pumps with bronze bodies, plastic impeller and EPDM rubber seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Dutypoint ‘VS’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels.. Maximum working pressure 10.0 bar. Cold water use only.
Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 11.03 Bar (Bypass) and 7.0 Bar (Operating).
Range of pumps with either brass or stainless-steel bodies, stainless steel impellor and NBR ‘O’ rings. 20 & 33 brass series have a maximum working pressure of 16.0 bar. 33 stainless-steel series has a maximum working pressure of 20.0 bar. 22, 24 ,26, 38, 31, 32 & 34 series have a maximum working pressure of 20.0 bar. Cold water use only.
Range of shower outlets with chromium plated bodies. Models P60901 and P61400 have check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. From July 2023, model P61400 can also be supplied without the check valve at the inlet. Maximum operating temperature 70°C.
Shower handset (various finishes) with built in flow restrictor. Maximum operating temperature 60°C.
Shower hose incorporating an EPDM liner and grey PET outer layer. Supplied with EPDM washers. Maximum operating temperature 70°C.
Range of shower handsets with a chrome plated body. Maximum operating temperature 60°C.
PVC lined, chrome plated shower hose. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies. Models P60901 and P61400 have check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Wall mounted shower intake, having a brass body (chrome plated). The outlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection) Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass bodies (various finishes). Maximum operating temperature 60°C.
Range of wall or ceiling mounted shower arms with brass bodies (various finishes). Maximum operating temperature 65°C.
Page 24 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.