Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of in-line ultrasonic water meters with DZR brass bodies. The following sizes only include a plastic strainer, DN15 - DN32 sizes (incorporated), DN40 size (optional). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of water meters with brass (CW724R & CC770S) and plastic (Composite) bodies, incorporating plastic strainers and EPDM ‘O’- rings. Maximum working pressure 16.0 Bar. Temperature: 60.0°C for brass (CW724R & CC770S) models & Cold water use only for composite models.
Range of ultrasonic water meters with plastic bodies. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with black epoxy coated bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.
Permanent filling device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. If the mains pressure is adequate and there is a drop in system pressure, then the two solenoid valves operate to allow water into the system via the transfer chamber. At all other times the normally open solenoid valve drains the transfer chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 5.0 Bar. Cold water use only.
Flow meter with stainless steel body. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
CR(I)(N)(E) ranges of multistage centrifugal pumps incorporating stainless steel impellers, intermediate chamber and outer sleeve. CR(E) versions have cast iron bases and pump heads coated with black cathodic paint. CRI(E) and CRN(E) versions have stainless steel bases and pumpheads. The pumps are available with the following shaft seals HQQ*, HUU*, HUB*, HQB*, where * can be E for EPDM and V for FKM. Maximum working pressures: CR1, 3 or 5 (2-36 stages) Oval flange: 16.0 bar. CR1, 3 or 5 (2-36 stages) DIN/ANSI/JIS flange: 25.0 bar CRI/N1, 3 or 5 (2-36 stages) Flexi clamp with oval flange connection: 16.0 bar CR/I/N1, 3 or 5 (2-36 stages) DIN/ANSI/JIS flange, PJE, Flexi clamp or Triclamp: 25.0 bar CR10 (1-16 stages) Oval flange or DIN/ANSI/JIS flange: 16.0 bar. CR10 (17-22 stages) DIN/ANSI/JIS flange: 25.0 bar. CRI10 (1-16 stages) PJE, Flexi clamp, Flexi clamp with oval connection, Triclamp or DIN/ANSI/JIS flange: 16.0 bar. CRI10 (17-22 stages) PJE, Flexi clamp, Triclamp or DIN/ANSI/JIS flange: 25.0 bar CRN10 (1-22 stages) PJE, Flexi clamp, Flexi clamp with oval connection, Triclamp or DIN/ANSI/JIS flange: 25.0 bar. CR15 or 20 (1-7 stages) Oval flange: 10.0 bar. CR15 or 20 (1-10 stages) DIN/ANSI/JIS flange: 16.0 bar. CR15 or 20 (11-17 stages) DIN/ANSI/JIS flange: 25.0 bar. CRI15 or 20 (1-7 stages) Flexi clamp with oval flange connection: 10.0 bar CRI15 or 20 (1-10 stages) PJE, Flexi clamp, Triclamp or DIN/ANSI/JIS flange: 16.0 bar. CRI15 or 20 (11-17 stages) PJE, Flexi clamp, Triclamp or DIN/ANSI/JIS flange: 25.0 bar. CRN15 or 20 (1-17 stages) PJE, Flexi clamp, Flexi clamp with oval connection, Triclamp or DIN/ANSI/JIS flange: 25.0 bar. CR models: Cold water use only. CRI/CRN models: Cold water use only and from April 2023 99°C.
CR(N)(E) ranges of vertical multistage centrifugal pumps with stainless steel (CRN models) or black polymer coated cast iron bodies (CR models) and a stainless steel impeller. The products are available with or without a sensor. Maximum working pressure: 16.0 bar - CR(N)(E) 32 range with 1-7 stages, CR(N)(E) 45 range with 1-5 stages, CR(N)(E) 64 range with 1-5 stages. 30.0 bar - CR(N)(E) 32 range with 8-14 stages, CR(N)(E) 45 range with 6-11 stages, CR(N)(E) 64 range with 6-8 stages. 33.0 bar - CR(N)(E) 45 range with 12-13 stages. Maximum operating temperature - CR models are cold water use only. CRN models are cold water use only up to February 2nd 2023, and 99°C from February 3rd 2023.
Range of circulator pumps with brass bodies, plastic impellor, and EPDM ‘O’-rings and seals. The COMFORT 15-14 BX prefix models incorporate a screwdriver operated isolation valve on the inlet and a non-return valve at the outlet. These are housed within 1” BSP (M) x ½” BSP (M) adaptors. Maximum working pressure 10.0 Bar. Maximum operating temperature 95°C.
Range of multistage pumps (VL and CL series) and submersible pumps (VN, CN, ES and CS series) with stainless steel bodies and impellers and NBR gaskets and ‘O’-rings. Maximum working pressure 15.0 bar (VL and CL series pumps only).
Range of circulator pumps with stainless steel bodies and a plastic impeller. All models are available with a plastic (composite) rotor can, the MAGNA1 range is also available with a stainless-steel rotor can in the DN32 flanged, threaded 1½ & 2” sizes only. The MAGMA3 models have a differential pressure sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of shower columns with an integral brass body and an aluminium painted column with chrome plated upper. Flow is controlled by a solenoid valve activated by an infrared sensor. The shower head inlet incorporates a combined NBR washer and stainless steel filter. The shower outlet incorporates a plastic flow regulator. The product is supplied with an inline ½” BSP (M) x ¾” BSP (F) screwdriver operated spherical valve with chromium plated brass bodies and ball for installation on the inlet. The product drains down after each use via an integral LLDPE tube leading to a drain outlet at the base of the column. Maximum working pressure 8.0 bar. Cold water use only.
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Wall mounted and ceiling mounted shower arms (chromium plated brass).
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall and ceiling mounted shower arms with (brass bodies - various styles and finishes). Maximum operating temperature 60°C. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Drain cock with a plastic body. Maximum working pressure 6.0 bar.
Non-metallic materials and components comply with BS6920 at 75°C
Page 24 of 48
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.