“Plimat ABS Fittings BS Inch and ABS Adaptor Fittings” range of ABS solvent cement or threaded fittings for use with “Plimat ABS pipe”. Maximum working pressure: 15.0 bar (fittings with ½” - 4” solvent cement connections), 9.0 bar (fittings with 5” or 6” solvent cement connections, with or without threaded connecitons), and 10.0 bar (fittings with threaded connections and ½” - 4” solvent cement connections). Cold water and above ground use only.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of dual flush WC syphons incorporating a polypropylene body, stainless steel C link and a LDPE sealing washer. The valve is to be operated via a handle lever. Cold water use only.
Range of urinal autosyphons with a plastic body & supplied with plastic backnuts.
Type "J" range of plate heat exchangers with stainless steel (AISI 304L) bodies and copper welding. Maximum working pressure 3.0 bar (Primary Circuit) and 10.0 bar (Secondary Circuit). Maximum operating temperature 80°C.
Range of indirect heat interface units providing heating and instantaneous hot water. The hot water and space heating is provided via two separate plate heat exchangers. The space heating circuit incorporates an expansion vessel and expansion relief valve (set @ 3.0 bar). The primary circuit only is supplied with isolation valves on the flow and return. Maximum working pressure primary 16.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water (DHW) 10.0 bar. Maximum operating temperature primary 75°C. Maximum operating temperature space heating 85°C. Maximum operating temperature secondary hot water (DHW) 65°C.
Range of ‘HYCO’ electric instantaneous water heaters with plastic bodies, NBR and silicone ‘O’-rings. The inlet of model IN96T incorporates a plastic strainer. Maximum working pressure 7.5 bar. Maximum operating temperature 60°C.
Plastic bodied flow sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower hoses and riser rail with chromium plated brass bodies, incorporating EPDM ‘O’-rings. Maximum operating temperature 85°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, intermediate chambers, shaft and outer sleeve. Cold water use only. Maximum working pressure 12.0 bar.
Range of submersible pumps incorporating stainless-steel bodies and plastic impellers. Maximum working pressure 23.0 bar or 36.0 bar (please refer to model). Maximum operating temperature 35°C.
Range of pumps incorporating a plastic body with stainless steel impellers, shaft and chambers. The inlet incorporate a stainless steel strainer. Maximum working pressure 2.4 bar (model HQ200). Maximum working pressure 3.1 bar (model HQ400). Maximum working pressure 3.3 bar (model HQ800). Cold water use only.
Range of cold water supply booster sets, incorporating a stainless steel manifold system and between 1 and 4 pumps depending on model. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels. Maximum working pressure 10.0 bar or 16.0 bar, dictated by the pump model(s) fitted. Cold water use only.
Range of shower booster pumps (either single or double) with acetal bodies and impellers and EPDM seals and NBR `O`-rings. Supplied with stainless-steel braided EPDM lined flexible hoses incorporating isolation valves Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.
Range of wall mounted shower outlets with brass bodies (various finishes). The 24 004 xxx, 24 014 xxx and 35 279 xxx models are supplied with ceiling mounted shower arm. The 24 005 xxx, 24 015 xxx, 35 275 xxx and 35 280 xxx supplied with wall mounted shower arm. The 24 005 xxx, 24 015 xxx, 35 275 xxx & 35 280 xxx models incorporate stainless steel strainers on the inlet. The 24 014 xxx & 24 015 xxx models incorporate plastic flow regulators on the inlet. Maximum operating temperature 60°C.
Stainless steel shower outlet with a swivel connection. Maximum operating temperature 65°C.
Range of ceiling mounted shower arms with brass bodies (various finishes) Maximum operating temperature 85°C
Range of overhead shower outlets with stainless steel bodies (various finishes - see model). The inlet incorporates a combined EPDM washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 80°C.
Wall mounted angled shower outlet with a brass body (various finishes) and NBR ‘O’-rings. The wall outlet and the inlet of the shower handset both incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working temperature 60°C.
Range of brass shower arms and plastic shower heads (various finishes) incorporating EPDM seals and ‘O’-rings, silicone seals and spray insert. The 26 469 xxx model is ceiling mounted & 26 470 xxx model is wall mounted. Both models incorporate a swivel joint housing a plastic flow regulator. Maximum operating temperature 60°C.
Page 3 of 205
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.