Range of five hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of combined bath fillers and overflows with a plastic body and a variety of different trims. The outlet incorporates a plastic flow regulator and the products are supplied with a cable operated pop-up waste. Maximum operating temperature 65°C.
Range of floor mounted, single hole, single outlet fixed combination tap assemblies (chromium plated brass with a self-cancelling diverter to shower outlet. The product incorporates a ceramic cartridge headwork and single lever operating member. The spout outlets incorporate an aerator and the product is supplied with a hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted spout outlet incorporating brass body (chrome plated) and NBR ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Uponor S-Press press fittings, Uni-X & Uni-C compression fittings for use with Uponor MLC pipe. Maximum working pressure 10.0 bar, maximum operating temperature 70°C.
Range of LK press fittings with brass bodies and stainless steel sleeves for use with LK Universal PEX pipe. Jointing is achieved by hydraulic compression. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of Aquaterra PP-RCT socket fusion fittings for use with Aquaterra PP-RCT SDR 6 pipe and Aquaterra PP-RCT SDR 7.4 pipe (manufactured to EN ISO 15874). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-Xc/Al/PE-Xc pipes. For above ground use only. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-RT/Al/PE-RT pipes. For above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
‘ISR’ range of copper, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
‘CB ISR’ range of capillary fittings with internal solder rings, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of copper and bronze capillary brazed fittings for use with copper pipe manufactured to EN1057:2006 +A1:2010. Maximum pressure 10.0 Bar (54mm up to and including 108mm) Maximum pressure 2.0 Bar (Over 108mm up to and including 159mm) Maximum operating temperature 100°C.
Range of brass caplillary fittings for use with EN1057 copper tube. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of brass caplillary fittings for use with EN1057 copper tube. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of brass compression fittings for use with copper pipe to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of press fittings incorporating copper or copper alloy bodies and EPDM O’-rings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
End Feed Range copper fittings for use with copper tube. For above and below ground use Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Page 3 of 212
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.