Nucyl ranges of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Stainless steel indirect thermal store. The primary circuit is factory fitted with a temperature and pressure relief valve (3 bar and 92°C). Hot water storage for space heating via air to water heat pump? Maximum working pressure: Primary circuit 3.0 bar Maximum operating temperature 85°C.
Range of “POWERflow” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 4.5 bar at 90˚C and an expansion relief valve set at 3.5 bar. The product is supplied with a pressure reducing valve set at 2.1 bar, expansion vessel, tundish and an approved check assembly (suitable for backflow protection against Fluid Category 2). Primary circuit max working pressure: 3.5 bar Secondary circuit max working pressure: 3.0 bar Solar Coil max working pressure: 3.5 bar Primary and Secondary circuit maximum operating temperature 75.0°C Solar Coil max operating temperature 80.0°C
Range of wall mounted, concealed, manual blending valves incorporating brass bodies and quarter turn ceramic disc headworks. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of wall mounted, concealed, manual blending valves with either a dome type or single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Wall mounted, manually operated blending valve, (brass body with a chromium plated brass trim set), incorporating a ceramic cartridge headwork with a single lever operating member controlling temperature and flow, and a manual diverter controlling the flow to the shower hose and handset or a secondary shower outlet. The product is supplied with a shower hose and handset. The handshower outlet connection and the shower handset inlet both incorporate an approved check valve cartridge, however the complete assembly has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, manually operated, concealed blending valve with a brass body incorporating a ceramic cartridge headwork with a single lever operating member controlling both flow and temperature. Maximum working pressure 5.0 bar. Maximum operating temperature 90°C.
Wall mounted manually operated, concealed blending valve (brass body) with a ceramic cartridge headwork controlling both flow and temperature with a XXXX operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 90.0 °C
Wall mounted, concealed, manual blending valve with DZR brass body and chrome plated trim set, incorporating a quarter turn ceramic disc headwork controlling the flow and a ceramic cartridge controlling the temperature independently, bothwith dome type operating members. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, concealed, manually operated blending valves with brass bodies or stainless-steel bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of wall mounted bar type thermostatic shower valves (chromium plated brass) incorporating a 2-way ceramic disc diverter headwork controlling the flow between an overhead shower outlet or a shower handset with dome or cube type operating members. The temperature is controlled independently via a thermostatic cartridge with dome or cube type operating member that also incorporates a manual override button. Both inlets incorporate stainless steel strainers and approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed thermostatic shower valves with DZR brass (F4000/HF concealed part) or brass bodies. Flow is controlled by either a 3-way (2 on, 1 off) or 4-way (3 on, 1 off) ceramic disc shower to shower diverter headwork (see model) with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. The inlets incorporate a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower mixer incorporating a chromium plated brass body and ceramic disc headwork with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which has a manual override button. The inlets incorporate a single check valve cartridge (however the complete assembly has not been tested to demonstrate they provide adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 90°C.
Range of wall mounted concealed thermostatic shower valves with DZR brass (CPHF4000HF concealed part) or brass bodies. Flow is controlled by either a 3-way (2 on, 1 off) or 4-way (3 on, 1 off) ceramic disc shower to shower diverter headwork (see model) with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. The inlets incorporate a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
‘Ausimix’ compact range of ‘T’-type thermostatic blending valves with nickel plated DZR brass bodies. Each inlet incorporates a stainless-steel strainer and a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The SBHEAT110780, SBHEAT110785, HEAT110780 & HEAT110785 models also have angled isolation valves at both inlets. Maximum working pressures and operating temperatures: Existing push fit models: For use with PEX pipe (manufactured to BS7291 part 3) and Polybutylene pipe (manufactured to BS7291 part 2): 12.0 bar, cold water use only. 6.0 bar @ 95°C. For use with copper pipe: Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. Compression models added October 2023: For use with copper pipe to BSEN1057:2006: Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of butterfly valves incorporating epoxy coated cast iron bodies, zinc coated iron discs and EPDM seats. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of lug type butterfly valves incorporating blue epoxy coated cast iron bodies, EPDM seats and stainless steel discs. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of wafer type butterfly valves incorporating blue epoxy coated cast iron bodies, EPDM seats and stainless steel discs. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of wafer and lugged type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs and EPDM seat. The closing mechanism can be controlled by either a lever, gear or bore shaft. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Series 900 range of wafer and lugged type, concentric butterfly valves with orange epoxy coated cast iron bodies, austenitic steel discs and EPDM seats. Maximum working pressure 16.0 bar. Cold water use only.
Page 19 of 213
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.