Range of four-hole, single outlet, fixed combination tap assemblies in chromium plated or matt black finished brass. Incorporating quarter ceramic disc headworks with single lever operating members. This product also incorporates a manual diverter to a shower outlet. The spout outlets incorporate a plastic aerators. Supplied with stainless steel braided PEX lined flex hose assemblies for connecting the spout and headworks. Not supplied with shower hose and handset. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted fixed spout outlets (brass or stainless-steel bodies – various finishes). Incorporating a self-cancelling diverter to shower outlet with a dome type operating member and a plastic aerator at the outlet. Most models are supplied with shower hose and handset. T2 models are not supplied with a shower handset.
Non-metallic materials and components comply with BS6920 at 65°C
Range of swivel spout outlets (brass or stainless-steel bodies - various finishes), incorporating plastic aerators.
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted spout outlet (brass body – various finishes) incorporating a plastic flow straightener. The inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60.0°C
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted spout outlet with chromium plated brass body incorporating a plastic flow regulator on the inlet and a plastic strainer at the outlet. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of horizontal or vertical expansion vessels with an EPDM membrane. Maximum working pressure 10.0 or 16.0 bar (please refer to model). Maximum operating temperature 100°C.
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Range of water filter cartridges (plastic bodies with a metal sleeve). Maximum working pressure 8.6 bar. Cold water use only.
Range of plastic fittings incorporating an EPDM ‘O’-rings for use with MIXAL pipe. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 95°C
Range of 'PF Press' TH Profile Brass Press Fittings for use with 'PF Press' Pert-al-Pert Multilayer pipe manufactured to EN ISO 21003 in sizes 16mm, 20mm, 26mm and 32mm. Maximum working pressure 10 bar. Maximum operating temperature: 16mm & 32mm - 95°C. 20mm & 26mm - 23°C between May 2023 to November 2023 and 95°C December 2023 onwards.
Range of brass bodied compression fittings for use with copper pipe(manufactured to EN1057). . Maximum working pressure 16.0 bar @ 30°C, 10.0 bar @ 65°C and 6.0 bar @ 100°C.
Range of compression fittings with brass bodies for use with copper pipe (EN1057). Above ground use only. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.
Range of electromagnetic water meters with rubber lined carbon steel bodies. Maximum working pressure 16.0 Bar. Maximum operating temperature 23.0°C.
Range of water meters with brass (CW724R & CC770S) and plastic (Composite) bodies, incorporating plastic strainers and EPDM ‘O’- rings. Maximum working pressure 16.0 Bar. Temperature: 60.0°C for brass (CW724R & CC770S) models & Cold water use only for composite models.
Wall elbow with a chrome plated brass body and NBR O-rings, the inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use
Non-metallic materials and components comply with BS6920 at 60°C
Flow regulator with a plastic body. 4.0 - 8.5L/min. Claims of flow regulation performance made by manufacturer have note been tested and are not covered as part of this approval.
Non-metallic materials and components comply with BS6920 at 85°C
Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.
Range of temperature measurement devices with bronze bodies and EPDM o-rings. Maximum operating pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Permanent filling devices for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. If the mains pressure is adequate and there is a drop in system pressure, then the two solenoid valves operate to allow water into the system via the transfer chamber. At all other times the normally open solenoid valve drains the transfer chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Stainless steel strainer on the inlet supply. Mikrofill 3: Maximum working pressure 5.0 Bar. Cold water use only. Mikrofill 3 Pro (72846): Maximum working pressure 9.0 Bar. Cold water use only.
Page 138 of 311
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.