Range of compression fittings with brass brass bodies for use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘KSO’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). The KSO14 sand KSO15 tap connector models incorporate an EPDM washer. Maximum working pressure 16.0 bar. Maximum working temperature 85˚C
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The 30065321,30065313, 30065317,30465313,30065301, 30065305, 30065309, 30465301 & 30465305 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The 950513 & 950514 & 950501, 950503 & 953102 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper capillary, bronze or brass end feed fittings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Non-metallic materials and components comply with BS6920 at 99°C
Range of end feed copper fittings for use with copper tube to EN 1057. The 950513, 950514, 950501, 950503 & 950502 models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Varipoint range of unvented water heaters with copper bodies, fitted with a temperature & pressure relief valve (7.0 bar) and supplied with a pressure relief valve (6.0 bar). Maximum working pressure 5.5 bar. Maximum operating temperature 85°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Brass fitting Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Biofilm and water quality monitor incorporating a stainless-steel body and silicon seals. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure: See models Maximum working temperature 85°C.
Range of shower handsets (chrome plated brass), shower hoses, handset brackets and cover plates. The shower handset inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60.0°C
Range of shower handsets with brass bodies, available with various finishes. The inlet incorporates a plastic regulator and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 80°C
Range of shower handsets with plastic bodies (chrome plated or white finish). Maximum operating temperature 60.0°C
Range of shower handsets and shower heads. The shower handsets have a plastic body (white), NBR ‘O’-rings, and a coloured locking ring around the shower face (see model section). The shower heads have a plastic body (white or chrome plated 02-093173 model), NBR ‘O’-rings, directional adjustment (ball joint) and a coloured interlocking ring either surrounding or central to the shower face (except for the 02-093165 and 02-093173 models which have no ring). The Wall shower T-L models have a combined NBR washer and stainless steel strainer on the inlet.
Wall mounted shower head arm incorporating a chrome plated brass body and EPDM O-rings. Maximum operating temperature 85°C.
Range of overhead shower outlets (chrome plated brass bodies) supplied with 4, 6, 9 way connectors and stainless-steel or nylon braided EPDM lined flexible hoses.. Maximum operating temperature 60°C.Open outlet only
Page 119 of 394
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.