Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a sequential headwork controlling both flow and temperature with single lever type operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Range of single hole, single outlet, fixed combination tap assemblies, (chrome plated brass bodies), incorporating ceramic cartridge headworks. The spout outlets incorporate plastic aerators (TTR1086 & TR1088) or flow straightener (TR1084). Maximum working pressure 5 bar. Maximum operating temperature 85°C
Range of single hole, single outlet (swivel), combination tap assemblies (brass bodies with various finishes), incorporating ceramic cartridge or quarter turn ceramic disc headworks with single lever, cross-top or dome operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 or 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, single outlet (fixed) combination tap assemblies (brass body, various finishes), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes), incorporating a ceramic cartridge headwork with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. Both inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of three-hole, metal, single outlet (fixed), wall mounted combination tap assemblies (brass body, black finish) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Inoxpres range of stainless-steel crimp fittings with EPDM ‘O’-rings and gasket for use with Inoxpres stainless-steel tube (1.4404 AISI 316L or 1.4521 AISI 444 – annealed or not-annealed). The connection is created by using a pressing tool. For above and below ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 95°C.
‘Tweetop system’ consisting of brass bodied nickel plated, compression or press fit (‘U’ crimping profile) fittings for use with ‘Tweetop multilayer pipe’ PERT/AL/PERT. Maximum working pressure 10.0 Bar. Maximum working temperature 95°C.
‘Hetta system’ consisting of brass bodied nickel plated, compression or press fit (‘U’ crimping profile) fittings for use with multilayer pipe PERT/AL/PERT. Maximum working pressure 10.0 Bar. Maximum working temperature 95°C.
Range of brass (Series 1000 & 1100) and DZR brass (Series 1100CZ) compression fittings, various finishes. For use with copper tube EN1057. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of SUS316L & SUS304 stainless steel press fittings for use with stainless steel pipe manufactured to EN 10312. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass press fittings with EPDM ‘O’-rings for use with PEX/AL/PEX multilayer pipe (manufactured to EN ISO 21003). Jointing is achieved via a crimping tool using either a ‘U’, ‘TH’ or ‘H’ profile. Maximum working pressure 10.0 bar. Cold water use only.
Range of wall mounted bib taps (chromium plated brass), incorporating a non-rising spindle headwork with a cross top operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Range of T type thermostatic blending valves with DZR brass bodies and EPDM O-rings. The inlets incorporate stainless steel strainers and single check valve cartridges verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of quarter turn, lever handle or butterfly operated spherical valves with nickel plated brass bodies, chrome plated brass balls and PTFE seals. For use with copper pipe BS EN 1057. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of quarter turn, lever handle or butterfly operated spherical valves with nickel plated brass bodies, chrome plated brass balls and PTFE seals. For use with copper pipe BS EN 1057. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
STAD range of balancing valves with brass bodies, PTFE sliding washer and EPDM O-rings. Models are available with or without a drain port. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
'DURAFIDE® 1140A1 WF9050 & DURAFIDE® 1140A1 WK9050'. Black coloured, injection moulded PPS materials. For use with water up to 85°C.
FORTRON® natural (appears cream) or black coloured, injection moulded PPS materials. For use with water up to 85°C. Grades manufactured in Celanese Florence, USA: FORTRON® 1140L4 SF3001 NATURAL FORTRON® 1140L4 SD3002 BLACK DW (formerly known as FORTRON® 1140L4 BLACK SD3002). FORTRON® 1140L6 SD3002 BLACK DW (formerly known as FORTRON® 1140L6 BLACK SD3002). FORTRON® 1140L6 SF3001 NATURAL FORTRON® 4184L6 SF3001 NATURAL FORTRON® 4184L6 SD3002 BLACK DW (formerly known as FORTRON® 4184L6 BLACK SD3002). Grades manufactured in Celanese Nanjing: FORTRON® 1140L4 SF3001 NATURAL DW (formerly known as FORTRON® 1140 L4 SF3001 natur CN). FORTRON® 1140L4 SD3002 BLACK DW (formerly known as FORTRON® 1140 L4 SD 3002 black).
Page 1 of 2
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.