Electric instantaneous, vented, mains water heater. Maximum operating temperature 98°C.
Range of in-line water meters incorporating bronze copper alloy bodies and EPDM O rings. Maximum working pressure 10.0 Bar Maximum operating temperature 30.0°C
Range of ultrasonic dry type water meters with brass bodies. Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C.
‘BECO Y’ range of ultrasonic water meters with plastic bodies, plastic transducers and silicone ‘O’-rings. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of below ground water meter manifolds with a plastic body and a spherical valve at the inlet. Models incorporate an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. For use with PE80 blue pipe (manufactured to BS EN 12201). Maximum working pressure 12.5 bar. Cold water use only.
Range of brass bodied threaded fittings and a brass end feed fitting (C04069H00081A model only). The CL08069H192B4 model is chrome plated. The C04069H00081A model end feed fitting is for use with copper pipe (manufactured to EN 1057). The C04149H00191A model incorporates a plastic flow straightener. Maximum working pressure 10.0 bar, except for the C04149H00190A and C04149H00191A models which are open outlet use only. Maximum operating temperature 85°C.
Threaded adaptor (brass body) soldered with copper pipe and a range of thread extensions (chrome plated brass bodies). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
CM(E) range of electronically operated pumps available in stainless steel, (‘EN 1.4301/AISI304’ or ‘EN 1.4401 /AISI316’) and cast iron. The pumps are supplied with Sic-Sic mechanical shaft seals and FKM or EPDM seals. Maximum operating parameters: Cast iron models: Maximum working pressure 6.0 bar @ 90°C. Maximum working pressure 10.0 bar @ 40°C. Stainless steel models (not self-priming variants): Maximum working pressure 10.0 bar @ 99°C. Maximum working pressure 16.0 bar @ 90°C. Stainless steel self-priming models (CM(E) 1, 3 & 5 (AISI 304) only): Maximum working pressure 10.0 or 16.0 bar @ 60°C.
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| JD-WH51-8** | Various | BSP 1/2" (F) | Open outlet use only bar | 60 °C | Kind | Inlet connector | No | ||||
| JD-WH51-10** | Various | BSP 1/2" (F) | Open outlet use only bar | 60 °C | Kind | Inlet connector | No | ||||
| JD-WH51-12** | Various | BSP 1/2" (F) | Open outlet use only bar | 60 °C | Kind | Inlet connector | No | ||||
| JD-WH52-8** | Various | BSP 1/2" (F) | Open outlet use only bar | 60 °C | Kind | Inlet connector | No | ||||
| JD-WH52-10** | Various | BSP 1/2" (F) | Open outlet use only bar | 60 °C | Kind | Inlet connector | No | ||||
| JD-WH52-12** | Various | BSP 1/2" (F) | Open outlet use only bar | 60 °C | Kind | Inlet connector | No | ||||
| JD-WH03** | Various | BSP 1/2" (M) | Open outlet use only bar | 60 °C | Kind | Body | No | ||||
| JD-WH05** | Various | BSP 1/2" (M) | Open outlet use only bar | 60 °C | Kind | Body | No | ||||
| JD-HA61** | Various | BSP 1/2" (M) | Open outlet use only bar | 60 °C | Kind | Body | No | ||||
| JD-HA60** | Various | BSP 1/2" (M) | Open outlet use only bar | 60 °C | Kind | Body | No | ||||
| JD-HA55** | Various | BSP 1/2" (M) | Open outlet use only bar | 60 °C | Kind | Body | No | ||||
| JD-HA54** | Various | BSP 1/2" (M) | Open outlet use only bar | 60 °C | Kind | Body | No |
The suffixes of ** represents different types of finishes as follows: C: Chrome NS: Nickel brushed RP: Red powder coated TS: Zr gold brushed RS: Rose gold brushed GS: Gold brushed GM: Gun metal brushed B: Electroplated matte black W: White CB: Matte black and chrome CW: White and chrome TG: Zr gold plated RG: Rose gold plated G: Gold plated GP: Gun metal plated BS: Gun gray brushed
Range of shower handsets with ABS bodies (various finishes, see model). The spray outlet is either multifunction or single function depending on series. Open outlet use only. Maximum operating temperature 60°C.
Range of wall mounted or ceiling mounted shower arms with brass bodies (various finishes - see model). Maximum operating temperature 65°C.
Range of In-line Y patterned strainers with ductle iron bodies (blue epoxy powder coated) and stainless-steel mesh. Maximum working pressure: 16 Bar Maximum operating temperature: 85 °C
Range of Y-pattern strainers with DZR brass bodies and stainless steel strainers. The compression connection is for use with copper pipe to BS EN1057. Maximum working pressure 20 bar (BSP threaded models ½”-2”), 16.0 bar (compression models). Maximum operating temperature 85°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of bib taps incorporating either brass or DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SD2001 | 1/2" BSP (M) | 16 bar | 85 °C | SD and size | Body | No | |||||
| SD2001 | 3/4" BSP (M) | 16 bar | 85 °C | SD and size | Body | No |
| Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 16 530 xx0 | Various | G 3/8 | 10 bar | 60 °C | AXOR | on body | Yes | 1/4 Turn ceramic disk | C-plate | Aerator |
Where xx0 denotes the surface finish (which is a non-water contact part). It will always be 3 digits, which can be any combination of numbers and/or letters, as examples: 000 = chrome optic finish, 800 = PVD stainless steel optic finish
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members and flow regulator in the inlet (1/2” only). The spout outlets incorporate a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure: 10.0 Bar Maximum operating temperature: 85°C
Range of flexible corrugated stainless-steel tubing with white plastic covering. Compression connections are for use with copper pipe (manufactured to EN 1057). Captive nut end connections incorporate an EPDM gasket. 2BACa0504 prefix models incorporate a servicing valve (chromium plated brass body with brass ball) on the compression end connection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of automatic air release valves with blue epoxy coated cast iron bodies and plastic floats. Maximum working pressure 10.0 Bar 16.0 Bar, 25.0 Bar (see models) Maximum operating temperature 60.0°C
Page 99 of 113
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.