Uponor ‘Q&E Shrink-Fit’ range of plastic (PPSU) or brass fittings for use with Uponor Radi pipe (PEX): 12mm, Uponor Combi pipe (PEX/EVOH/PEX): 16-40mm, and Uponor Aqua pipe (PEX): 40-63mm. Jointing is achieved via swaging tool. Uponor ‘Q&E’ adapters for soldering, solder ends are for use with copper pipe (manufactured to EN 1057). Operating parameters when used with the following pipes: 12mm Radi pipe, 16-25mm Combi pipe and 40-63mm Aqua pipe: Maximum working pressure 12.0 bar @ 20°C. Maximum working pressure 6.0 bar @ 95°C. From November 2022: 32-40mm Combi pipe: Maximum working pressure 12.0 bar @ 20°C. Maximum working pressure 6.0 bar @ 70°C.
‘WSR S/R’ Range of solder ring copper fittings for use with copper tube to BS EN 1057. Maximum working pressure 16 bar. Maximum working temperature 99°C
Jason range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of black coloured, PE100 butt fusion fittings for use with PE100 pipes (manufactured to EN 12201). Maximum working pressure for fittings used with SDR11 pipe is 16.0 bar and for fittings used with SDR17 pipe is 10.0 bar. For above and below ground use. Cold water use only.
Henco Press Brass (P) and Henco Press Black coloured (PK) ranges of press fit fittings (brass or PVDF bodies) for use with Henco RIXc PEXc/Al/PEXc pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Henco Schroef (EK) range of compression fitting (brass or PVDF bodies) for use with Henco RIXc PEXc/Al/PEXc pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
‘Mapress’ range copper or copper and brass “copper-press” fittings with butyl rubber (up to 54mm) or EPDM rubber (>54mm) ‘O’-rings for use with copper pipe to BS EN 1057. For above ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
WC direct flush valve consisting of a solenoid valve that controls the flow. The solenoid can be operated via a infrared sensor or a control button. The product incorporates a flow restrictor and supplied with 90,100 and 125 Ltr/min flow regulators. Maximum working pressure – 2.0 Bar Maximum operating temperature - 23 °C
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of water meters with blue epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Cold water use only.
Mitsubishi PPSU elbow fitting with a quick connect clip. Maximum Working Pressure: 6 Bar Maximum Working Temperature: 80°C
Horizontal end suction centrifugal pump with a 316 stainless steel casing, impeller and shaft. Maximum working pressure 16 bar. Maximum operating temperature 100°C
Range of showers handsets incorporating plastic bodies (chrome plated) Maximum operating temperature 60°C.
Range of shower handsets with ABS bodies available in various finishes. Maximum operating temperature 85°C.
Range of chrome plated hand showers with plastic bodies. The inlets incorporate a plastic strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
A range of overhead shower outlets with chromium plated brass bodies. The inlet of all models incorporate plastic filters. The inlet of all models, except 28.778.000, incorporate plastic flow restrictors. Maximum operating temperature 60°C.
Gold effect plated brass, wall mounted shower arm and head. The inlet of the shower head incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets with chrome plated plastic bodies. The inlets incorporate a plastic flow regulator and strainer. Maximum operating temperature 60°C.
Tempomix 3 794BOX1 concealed, wall mounted shower valve (brass body) for use with Tempomix 3 794218 & Tempomix 3 794219 functional/trim (chromium plated brass) kits. The functional/trim kits incorporate a self-closing spring-loaded headwork with a dome type operating member that controls both flow and temperature. 794219 also incorporates a chrome plated brass shower outlet that has a flow regulator. The inlets to the 794BOX1 incorporate stop valves, plastic filters and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Overhead shower outlets with brass bodies (various finishes), incorporating EPDM O rings. Maximum working pressure: Open outlet Maximum operating temperature 60.0°C
Range of shower handsets (chrome plated brass bodies). The shower handset incorporates an approved check valve cartridge with a flow regulator, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Plastic shower handset with flexible shower hose and brass wall outlet. Maximum operating temperature 60°C
Range of shower handsets with plastic bodies (various finishes - see model). The E082051.XXXAWZZ and E082073.XXXAWZZ models incorporate a combined TPE washer and stainless steel strainer on the inlet. Maximum operating temperature 65°C.
Wall mounted bib taps (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Pillar taps (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks, available with either cross top (M3101 & M3102) or single lever (M3201 & M3202) operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal back nuts Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of stainless steel or nylon braided, PEX lined flexible hose assemblies with various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘S800’ flexible reinforced hose assembly with dual layered (black inner & grey outer) and PVC lining with a plastic strainer. Maximum working pressure 10.0 bar. Hoses manufactured from 2023: Maximum operating temperature: 60°C
Range of PVC or EPDM lined shower hoses with stainless steel outer (chrome or black finish) or PVC reinforced (chrome plated finish) outer layer. Maximum operating temperature 65°C.
Range of PVC lined shower hoses with black inner layer and silver plastic outer layer. Maximum operating temperature 60˚C.
Range of stainless steel or nylon braided, PEX lined flexible hoses with a variety of end connectors. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Elisa Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of stainless steel interlocked (H35 models) or nylon braided (H36 models) flexible hose assemblies. H35 models are available with either a silicone or TPE liner, the H36 models are available with a TPE liner only. Maximum operating temperature 60°C.
Range of stainless steel or nylon braided, PEX or EPDM inner liner flexible hose assemblies available in a range of various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel or nylon braided, thermoplastic silicone rubber (TPSiV) lined flexible hoses with a variety of end connectors. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of indirect unvented indoor heat pump storage cylinders which consist of a heat pump which sits on top of the tank and heats the hot water via refrigeration pipes which then heats the cylinder by being externally mounted around the cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressure 6.0 Bar (Secondary) Maximum operating temperature 55.0°C
Wall mounted, bar type, thermostatic shower mixer (chromium plated brass), incorporating a 2-way ceramic disc diverter headwork with a dome type operating member controlling the flow between each shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The product is supplied with a shower hose (metal interlocked), shower handset (chrome plated), riser rail and overhead shower. The shower handset and the overhead shower both incorporate a stainless-steel strainer on the inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic shower mixing valves (chromium plated brass). The products incorporate a ¼ turn ceramic disc or a 2-way ceramic disc diverter headwork (see model). Temperature is controlled independently via a thermostatic cartridge with a manual override button. All models have cube operating members except model 706128 which has dome operating member. Each inlet incorporates a combined EPDM washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Wall mounted thermostatic blending valve (chromium plated brass). Temperature is controlled via a thermostatic cartridge with a cube operating member incorporating a manual override and the flow is controlled via two push type cartridges for the shower outlets. The inlets incorporate stainless steel strainers and approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic shower valves with brass bodies (various finishes), incorporating a thermostatic cartridge controlling the temperature and a push shut-off valve controlling the flow. The inlets and the shower outlet incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Wall mounted, manually operated blending valve with a brass body (various finishes) and ceramic cartridge headwork a single lever operating member. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Range of wall mounted, thermostatic shower valves with brass bodies (various finishes). Flow is controlled with a ceramic disc headwork with a single lever operating member. Temperature is controlled independently by a thermostatic cartridge with a single lever operating member with a manual override button. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Wall mounted, manual blending valve (brass body, various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. This product is not claimed to provide any backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of thermostatic shower panels incorporating a single sequential thermostatic control valve with a single lever operating member and flexible riser kit. Each inlet supplied with a servicing valve, EPDM o-ring and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with black lined PVC shower hoses and chrome plated shower handsets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of wall mounted concealed thermostatic blending valves with plastic bodies (various finished face plates). The flow is controlled by a ceramic disc diverter headworks with a cube type operating members. The temperature is controlled by a thermostatic cartridge with dome type operating members incorporating a manual override button. Both inlets incorporate an approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower valve with brass body (various finishes), incorporating a ceramic disc diverter that controlling the flow with a cube type operating member. The temperature is controlled independently via a thermostatic cartridge with a cube type operating member incorporating a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted concealed (BIV & BIR models) and exposed (EV model) thermostatic shower control valves. The bodies are cast brass (concealed versions) with a chromium plated trim set or chromium plated brass (exposed versions). Flow and temperature are controlled by a thermostatic cartridge with a single lever operating member. The inlets incorpoarate stainless steel strainers. Some models are supplied with a shower hose and handset or an overhead shower arm and shower head with flow regulator (see model section). The BIV model is also supplied with an angled wall outlet elbow. Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Range of concealed manual diverters (brass bodies) with chrome trim sets, model RAKPES3020-1C incorporating a dome type operating member and model RAKPER3020-1C incorporating a single lever operating member. Maximum working pressure – 5.0 Bar Maximum operating temperature - 85 °C
Range of pressure reducing valves with DZR brass, gunmetal or stainless-steel bodies. Maximum inlet pressure for HP and SP Models = 25.0 bar. Maximum inlet pressure for LP Models = 6.0 bar. Between September 2022 and December 2023, the maximum operating temperature of models included on the approval was 60°C. From January 2024, the maximum operating temperature of those models increased to 85°C. Models added to the approval in January 2024: Models with maximum working pressure of 6.0 & 16.0 bar models are for cold water use. Models with maximum working pressure of 25.0 bar have a maximum operating temperature of 85°C.
Page 92 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.