Range of floor mounted, two-hole, single outlet (swivel) combination tap assemblies (stainless steel and brass bodies various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 70.0°C
Range of two hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated). Incorporating non-rising spindle headworks with dome type operating members (model 922040) and ceramic disc headwork with single lever operating members (model 922075). The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The products are supplied with a shower hose and handset, and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (various finishes - see model), incorporating quarter turn ceramic disc headworks and either single lever or dome type operating members (see model). The spout inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes). Incorporating quarter turn ceramic disc and various operating members. The spout outlet incorporates a plastic aerator (except Broadway and Niagara spout options). The product is supplied with nylon braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections on both ends or at one end and M10 at the other. The hoses are intended to connect between the side body headworks and the spout junction. The spout junction of the Malmaison and Niagara spout options incorporates a plastic flow regulator. The product is also supplied with either a click type or pop-up waste (see model), and a ½” BSP (F) nut and NBR washer to adapt the side valve inlet connections. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes). Incorporating quarter turn ceramic disc and various operating members. The spout outlet incorporates a plastic aerator. The product is supplied with nylon braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections on both ends or at one end and M10 at the other. The hoses are intended to connect between the side body headworks and the spout junction. The product is also supplied with a pop-up waste, and a ½” BSP (F) nut and NBR washer to adapt the side valve inlet connections. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes), quarter turn ceramic disc headwork and choice of single lever or dome type operating members. The spout outlets incorporate a plastic aerator. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for connecting the side body headworks and the spout junction. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass spout and trim set), incorporating quarter turn ceramic disc headworks with dome type operating members. The inlet of the spout incorporates a plastic flow regulator, and the spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet, (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks with dome type operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for connecting the side body headworks and the spout junction. The spout inlet incorporates a plastic flow restrictor, and the spout outlet incorporates plastic aerator. The products are supplied with click type pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (various finishes, see models) incorporating quarter turn ceramic disc headworks with wheel type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted spout outlets with brass bodies (chrome plated). Product is supplied with various operating members and pop up click waste. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Wall mounted waterfall, bath spout (chromium plated brass), incorporating a flow regulator on the inlet and stainless-steel strainer at the spout outlet. Maximum operating temperature 80°C. Open outlet use only
Range of wall mounted spout outlets, (brass bodies with various finishes) incorporating a plastic aerator. Maximum operating temperature: 60°C
Chlorine Dioxide dosing system consisting of various PVC pipes and fittings, a water meter and a spherical valve. The inlet incorporates a double check valve assembly (verified by test as suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Cold water use only.
‘CD3 Series’ chlorine dioxide dosing system incorporating a single check valve positioned at the point of injection. Maximum working pressure 6.0 bar. Cold water use only.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Models VB8, VB12, VB18 & VB24 have a maximum working pressure of 16.0 bar. All other models have a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Range of expansion vessels with stainless steel and epoxy coated carbon steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
‘Profine’ plastic bodied filter head incorporating EPDM ‘O’-rings for use with filter cartridges (not supplied).For use with LLDPE tube (manufactured to DIN 8072). All models can be specified with or without an integral bracket. Maximum working pressure 6.0 bar. Cold water use only.
Range of carbon block water filters and housings. Maximum working pressure 10.5 bar. Cold water use only.
Range of water filter housings with plastic heads and bodies (various colours - see model), incorporating NBR ‘O’-rings (158087/088/207/208/218/219/261 models only) or with EPDM ‘O’-rings (all other models). Big Blue for Cartridges - Maximum working pressure 6.9 bar (10” filter housings) and 6.2 bar (20” filter housings). Maximum working temp 38°C. All other models - Maximum working pressure 8.62 bar. Maximum working temp 52°C.
Page 86 of 508
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.