Range of water meter manifolds incorporated into a meter chamber. The inlet of all models incorporates an isolation valve and an approved check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. MK7000003003 is for use with MDPE plastic pipe (manufactured to BS EN 12202-1:2011). Maximum working pressure 12.5 bar. Cold water use only.


Range of electronic pump controllers with plastic bodies. Maximum working pressure 12.0 Bar. Cold water use only.
‘UPM10’ and ‘UPM20’ range of circulator pumps with a stainless-steel body, plastic impellor and EPDM ‘O’-rings. The product is supplied with EPDM gaskets for the inlet and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
'HYDRO MULTI-E' booster set range consisting of two to four electronically controlled pumps connected in parallel and mounted on a common base frame provided with all necessary fittings. The suction manifold incorporates an isolation valve fitted between it and the individual pumps, and a pressure switch with an isolation valve. The discharge manifold incorporates an isolation valve and a non-return valve (not suitable for backflow protection), which is fitted between it and the individual pumps, it also incorporates a combined isolation and drain valve. Maximum working pressure 16.0 bar. Cold water use only.
Range of pumps with plastic bodies, pistons and TPE diaphragm. For use with John Guest LLDPE pipe. The products incorporate non-return valves (not suitable for backflow protection). Maximum working pressure: 8.27 Bar. Cold water use only.
Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. 9Maximum operating temperature 80°C.
Range of shower outlets (brass bodies - various finishes) a plastic flow regulator in the inlet. Maximum working temperature 85°C.
Range of shower handsets with ABS plastic bodies (various finishes, see models). Maximum operating temperature (see models).
Range of plastic bodied shower outlets, available in chrome plated or black finish (AQ055082 and B suffix models only). The overhead showers incorporate a combined silicone washer and stainless steel strainer on the inlet. Maximum operating temperatures: 65°C (AQ055062, AQ055063 & AQ055081 models). 75°C (all other models).
Range of shower handsets with plastic bodies incorporating an integral filter. The inlet incorporates a combined washer and a strainer, plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C. Open outlet use only.
Range of (chrome plated) plastic shower handsets, each supplied with five (optional) plastic flow regulators (x2 blue, light green, dark green and grey). Maximum operating temperature 60°C.
Range of in-line Y patterned strainers with bronze bodies and a stainless-steel mesh. Maximum working pressure: 25 Bar. Maximum operating temperature: 66°C
Range of flanged `Y` patterned in-line strainers with blue epoxy coated ductile iron bodies, stainless steel mesh. Maximum working pressure 16 Bar. Maximum operating temperature 85°C.
Range of In-line ‘Y’ patterned strainer with ductile iron bodies (blue epoxy powder coated) and stainless-steel screens. Maximum working pressure 16.0 bar. Maximum operating temperature 85ºC.
Range of In-line ‘Y’ patterned strainer with ductile iron bodies (blue epoxy powder coated) and stainless-steel screens. Maximum working pressure 16.0 bar. Maximum operating temperature 85ºC.
Range of bib taps (chrome plated brass) or (DZR brass) bodies – see models, incorporating a spherical valve to control the flow. The products incorporate single lever operating members. Some models are supplied with lock shields (see models). The spout outlet incorporates a hose union spigot connection with a plastic flow straightener. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Self closing basin tap (chromium plated brass) with spring loaded headwork and dome type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar, Maximum operating temperature 85°C.
Range of nylon braided PEX lined flexible hose assemblies with EPDM washers and ‘O’-rings with a variety of end connections. Maximum operating temperature 65.0°C
Range of plastic braided PEX lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of flexible shower hose assemblies comprising of a PVC inner, multi-layered hose (silver external appearance), with silicone ‘O’-rings and washers. Maximum operating temperature: 60°C. Open Outlet use only.
Page 82 of 124
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.