Range of wall mounted, concealed thermostatic shower valves (brass bodies – various finished trim sets). All models comprise of an iBox that can consist of the following combinations. iBox incorporating a thermostatic cartridge with a dome type operating member. iBox incorporating a thermostatic cartridge with a dome type operating member and a detent headwork with a push button operating member to a shower outlet. iBox incorporating a thermostatic cartridge with a dome type operating member and two detent headworks with push button headworks to multiple shower outlets. iBox incorporating a thermostatic cartridge with a dome type operating member, two detent headworks with push button operating members to shower outlets and an internal shut off valve. All models incorporate approved single check valve cartridges, however, the complete assembly has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C Models added December 2024: Maximum operating temperature 60.0°C
Range of wall mounted, thermostatic blending valves (brass bodies – various finishes), incorporating a ceramic disc headwork controlling the flow with a dome type operating member, temperature is controlled via a thermostatic cartridge with a dome type operating member incorporating a manual override button. The product is supplied with a shower hose, handset and overhead shower. The outlet to the shower hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower handset inlet incorporates a plastic flow regulator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of wall mounted, concealed, thermostatic blending valves with brass bodies in various finishes. The flow is controlled via ceramic disc or push-button headwork with dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted, thermostatic blending valves, (brass bodies various finishes), incorporating a quarter turn ceramic disc headwork controlling the flow.Temperature is controlled independently via a thermostatic cartridge with a manual override button incorporating dome or lever type operating members, Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower valves incorporating detent headworks controlling the flow. Temperature is controlled via a thermostatic cartridge incorporating a manual override button. Both inlets incorporate approved single check valve cartridges (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection). The products are supplied with a shower hose, shower handset and over head shower. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted, exposed, thermostatic shower valves (chromium plated brass) incorporating a single sequential headwork controlling both flow and temperature with a single lever operating member. The products are supplied with 15mm compression inlet elbows incorporating approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets also incorporate plastic flow regulators. The 90033CP model can have either a top or bottom outlet, which is achieved by re-positioning the blanking plug and threaded outlet. The compression connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of handwheel operated butterfly valves with blue epoxy coated ductile iron bodies and EPDM rubber seat. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C
Range of butterfly valves with blue epoxy coated ductile iron bodies and discs, and EPDM seals with a wheel type operating member. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Non-metallic materials and components comply with BS6920 at 85°C
Range of deck mounted flow control valves which incorporate a quarter-turn ceramic disc headworks with a variety of operating members. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.
Range of non-return valves housed within a blue epoxy coated ductile iron body. Maximum working pressure 16.0 bar. Maximum operating temperature 80ºC.
Range of non-return, swing gate valves with gunmetal bronze bodies. Maximum working pressure 20.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of non-return, swing gate valves with gunmetal bronze bodies. Maximum working pressure 20.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of bronze swing gate valves incorporating a bronze disc with a metal-to-metal seal. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of lever or butterfly operated spherical valves with brass or nickel plate bodies and ball. Maximum working pressure: Various – see model section. Maximum operating temperature 99.0°C
Range of full-bore spherical valves with a brass body (nickel plated), brass ball (chrome plated) and PTFE seats. All models are available as lever operated, 15-28mm sizes are also available with a butterfly handle. For use with copper pipe (manufactured to BS EN 1057). Maximum working pressure 25.0 bar. BS6920 85°C.
Range of inline, T-piece or angled screwdriver operated spherical valves with brass or chrome plated brass bodies and ball, for use with copper pipe to BS EN 1057 and Stainless steel to EN 10312. Maximum working pressure 10.0 Bar Models 1GLB311NP-SD, 1GLB411NP-SD, 1GLB111, 1GLB121 – 16.0 Bar Maximum operating temperature 85°C
Range of spherical valves with a brass body, brass ball, PTFE seats and lever type operating members. Maximum working pressure 40.0 Bar Maximum operating temperature 65.0°C
Range of angle valves (brass bodies – various finishes), incorporating non-rising spindle headworks with a dome type operating members and NBR O-rings and PTFE Seals. Maximum working pressure 10 bar. Maximum operating temperature – Cold Water Use
Range of spherical valves with nickel plated brass bodies, chromium plated brass balls and various operating members (see models). Products incorporate EPDM O-rings and PTFE seats. Maximum working pressure ½” – 1” 30 bar, 1 ¼” – 2” 25 bar. Maximum operating temperature 100°C.
Range of lever operated spherical valves with brass bodies (chromium plated), incorporating chromium plated balls and PTFE seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with DZR brass bodies, stems and discs. The valves operate via a hand wheel (non-rising) and a metal to metal seal. Valves are for above ground use only. Maximum working pressure 16.0 Bar. Maximum operating temperature 85.0°C.
Range of non-rising spindle gate valves with bronze bodies, incorporating hand wheel operating members. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 85°C
Range of gate valves with blue epoxy ductile iron bodies and wedges incorporating PTFE seals and a non-rising spindle (16Q models) or outside screw and yoke (125Q models). The valves incorporate a handwheel operating member. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Range of resilient seated gate valves incorporating blue epoxy coated ductile iron body and EPDM gaskets with a handwheel operating member. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C
Range of gate valves incorporating blue epoxy coted ductile iron bodies, ductile iron wedges encapsulated in EPDM and an EPDM gasket and seal. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of screw down stop valves with brass bodies, NBR seals and ‘T’ type operating members. Compression connection to be used with copper pipe EN1057 only. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Range of commercial washing machines with flow controlled by solenoid valves and discharged via type AB air gap assembly (verified by test - suitable for backflow protection against fluid category 5). The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
Range of magnetic scale inhibitors incorporating nickel plated copper bodies. Maximum working pressure 10.0 bar. Cold water use only.
ClearScale Plus range of in-line water conditioners with stainless steel bodies and catalytic alloy core. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of inline water conditioners with stainless steel bodies and catalytic alloy core. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
‘POLYLAC® PA-747'. Natural (beige coloured), injection moulded ABS material. For use with water up to 85°C.
'ELECTROCOAT BP 1119'. Factory applied, black coloured Bituminous Paint. Apply as per manufacturer's TDS Document No: 'ECL/ TDS / BP-1119-Bituminous Paint', Issue Date '10-Aug-20', Version No: '01'. Cure for 12 minutes at 45°C, followed by 10 hours at 28°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'AK-SSIC'. Grey coloured, sintered silicon carbide ring component. Between January 2024 and March 2024, the component is for use with water up to 23°C. From April 2024, the component is for use with water up to 85°C.
'LUBERPOX-2K-DS-LACKFARBE (IV81 & IW81)’ – blue coloured and ‘LUBERPOX-2K-DS-LACKFARBE (IV81812 & IW81)’ – red coloured’. Factory applied, two component, epoxy coatings consisting of IV81 or IV81812 (base) and IW81 (hardener). Mix IV81 or IV81812 (base) & IW81 (hardener) in a mass ratio of 5:1 or volume ratio of 3.5:1 and apply as per manufacturer’s data sheets ‘Rev: 04 – 04.12.2023’ (blue) or ‘Rev: 03 – 04.12.2023’ (red). Cure for 20 minutes@22°C and then 40 minutes@75°C. For use with water up to 65°C. These materials are only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'JBG-SRPC Plus'. Factory applied, sulphate resisting Portland cement intended to line ductile iron pipes. Mix sand:cement:water in a 3:2:1 ratio and apply as per manufacturer's instructions 'JBIL/IFU-01' dated '29.01.2024'. Cure for 28 days@40°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'JBG-OPC Plus'. Factory applied, grey coloured, ordinary Portland cement intended to line ductile iron pipes. Mix sand:cement:water in a 3:2:1 ratio and apply as per manufacturer's instructions 'JBIL/IFU-01' dated '29.01.2024'. Cure for 28 days@40°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'LRPOLO22-V'. Factory applied, clear vinyl-ester resin. Apply as per manufacturer's TDS 'LRF-QAC-FM-003, Rev 02', dated '27th Dec 2022'. Cure for 24 hours@25°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'LRPOLO22-ISO'. Factory applied, yellow coloured Isophthalic Polyester Resin. Apply as per manufacturer's TDS 'LRF-QAC-FM-002, Rev 02', dated '27th Dec 2022'. Cure for 24 hours@25°C. For use with water up to 45°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘NATZINC EP9015 SC PART A-BI.5431 Primer for use with HYDRALFUN AC BLEU PAM RAL5005-CZL8190 Coating’. Factory applied, dark blue coloured (once applied), powder coating for use with two-part epoxy primer. Mix parts A & B of primer in a 100:10 mass ratio and apply as per manufacturer’s TDS dated February 2024. Cure for 24 hrs at 20°C. Apply coating as per manufacturer’s TDS dated February 2024 and cure for 21 days at 20°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'KAJ1207'. Factory applied, blue coloured epoxy coating. Apply as per manufacturer's instructions 'file no. I01-KAJ1207' dated '2019.1.14'. Cure for 15 minutes@200°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
`WEY-Black, WEY-Red & WEY-Blue`. Factory applied epoxy coatings. Apply and cure as per manufacturer's TDS dated '24/11/2021'. For use with water up to 85°C.
'TEFRO®cor 150SW-LV'. Grey coloured, factory applied epoxy coating. Mix in a 6:1 weight ratio (4:1 volume ratio) and apply as per manufacturer's Product Data Sheet, 'Revision Status 02/11/2023'. Cure for 7 days at 23°C. For use with water up to 40°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'18521 Kanepox Lining Free Cream or Red for use with Kanepox Hardener 0362'. Factory applied, two-part, cream or red coloured epoxy coatings consisting of component A (18521) and component B (0362). Mix and apply as per date sheet ‘Rev. No. 11’ dated February 2018. Cure for 7 days@23°C. The cream coating is for use with water up to 50°C. Between February 2024 and August 2024, the red coating is for use with water up to 23°C. From September 2024 the red coating is for use with water up to 50°C. These materials are only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
‘Hempadur 3556K’. Factory applied, cream coloured epoxy coating consisting of a two-part primer and two-part top coat. The two-part primer is Hempadur 15590 red (56880) and this is mixed in a volume ratio of 7.93:2.14 and applied as per manufacturer's Product Data Sheet dated February 2024. Cure for 24 hours@20°C. The two-part top coat is Hempadur 3556K cream (20320) and this is mixed in a volume ratio of 6.8:2 and applied as per manufacturer's Product Data Sheet dated March 2024. Cure for 7 days@20°C. For use with water up to 35°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
‘Hempadur 3556K’. Factory applied, cream coloured epoxy coating consisting of a two-part first coat and two-part second coat. The two-part first coat is Hempadur 3556K light red (50900) and this is mixed in a volume ratio of 6.8:2 and then cured for 24 hours@20°C. The two-part second coat is Hempadur 3556K cream (20320) and this is mixed in a volume ratio of 6.8:2 and then cured for 7 days@20°C. For use with water up to 35°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Hempaline® Defend 630 Cure 72', blue coloured coating. Between February 2024 and April 2025, the blue coloured coating was for use with water up to 50°C. Between May 2025 and February 2029, the blue coloured coating is for use with water up to 80°C. In May 2025, 'Hempaline® Defend 630 Cure 72', white coloured coating was added to the approval. For use with water up to 80°C. Factory applied, two-part epoxy phenolic coatings consisting of a base and curing agent. Mix base and curing agent in a 4:1 volume ratio and apply as per manufacturer's Product Data Sheet dated May 2025. Cure for 6 days@20°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘PRIMER NATZINC EP9015 SC PART A’ Primer for use with ' HYDRALFUN AC BLEU PAM RAL5005-CZL8190 ' top-coat. Factory applied, blue coloured (once applied) primer and finish-coat. Mix base:hardener of primer in a 100:10 weight ratio and apply as per manufacturer’s TDS February 2024. Then apply top-coat as per manufacturer’s TDS February 2024. Cure for 21 days@23°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Raymond Microsilica Modified Cement Mortar Standard A'. Site applied, grey coloured cement mortar. Mix cement/sand in a 1:1.1 mass ratio. To this add micro silica at 7%, achieved by mixing cement mix/micro silica in a mass ratio of 1:0.07 and water at 1:0.32 (cement mix/water). Add the MasterPozzolith 55R at a ratio of 2.2ml per kilo of cement. Apply as per manufacturer’s TDS ‘TDS/RI/2024/MMCM “Standard A’, dated ‘ 21 Feb 2024’. Cure for 28 days at a temperature of between 10°C and 35°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'ES 988 DWPU'. Site applied, two-component polyurethane coatings which are available in blue or grey colours (once mixed). Mix Part A (blue or grey opaque liquid) with Part B (amber, translucent liquid) in a 100:30.5 weight ratio and apply as per manufacturer's technical data sheet 'TDS507DWPU.rv2.17102018'. Cure for 14 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
‘Sikagard®-180’. Site applied, grey coloured, two-component epoxy coating consisting of Part A (grey coloured liquid) and Part B (colourless liquid). Mix Part A and Part B in a mass ratio of 87:13 and apply as per manufacturer's TDS 'MBS_CC-UAE/Pr_180_05_18/v9/02_22/v10/05_23/v11/01_24'. Cure coat 1 for 36 hours@20°C. Cure coat 2 for 21 days@20°C. For use with water up to 40°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 76 of 125
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.