Range of floor mounted single hole, single outlet (fixed), combination tap assembly (various plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet with a dome type operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The pull-out spout outlet incorporates a plastic aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) pull out spray combination tap assemblies (brass bodies – various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. The outlet incorporates a plastic aerator and a push button spray. The connection between the outlet and the hose incorporates an approved single check valve cartridge, however, the whole product has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60.0°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chromium plated), incorporating ceramic cartridge headworks and single lever operating member. The connection to flexible hose and spray outlets incorporates an approved single check valve cartridge (however, the whole product has not been fully tested to demonstrate that it provides adequate backflow protection) the outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate an aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure; 10 Bar Maximum operating temperature 65°C
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies), incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator Maximum working pressure 10.0 bar. Maximum operating temperature: 70°C.
Range of two hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal or plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with dome operating members. The spout outlets incorporate plastic aerators or flow straighteners. The product is supplied with metal back nuts. Maximum working pressure – 10.0 Bar Maximum operating temperature - 70 °C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates plastic aerators. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 70 °C
Range of two hole, single outlet, fixed, wall mounted shower valves (chromium plated brass bodies), incorporating a ceramic cartridge headwork with single lever operating members. The products incorporate a plastic aerator on the outlet and the inlets incorporate a stainless-steel strainer and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. All models incorporate a straight connector servicing valve located on both inlets. Maximum working pressure 5 Bar Maximum operating temperature 60°C
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headworks with single lever operating members and a self-cancelling diverter to shower outlet with Type HC device (verified by test - suitable for backflow protection against Fluid Category 3 The spout outlet incorporates an aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted spout outlets (brass bodies - various plated) incorporating a plastic aerator. Maximum operating temperature: 60 °C
Deck mounted spout outlet with chromium plated brass body incorporating a plastic aerator. Maximum operating temperature 60°C.
Wall mounted spout outlet, (chromium plated brass body) incorporating a plastic aerator. Maximum operating temperature 60°C.
Range of Grohe ‘Atrio’ wall mounted spout outlets (brass bodies - various finishes), the outlet incorporates a plastic aerator. Maximum operating temperature: 60°C
Page 416 of 505
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.