Range of Victaulic rigid couplings (905, H10, H11, H20, H50) for use with plain end HDPE pipe (EN 12201-2), and for product 907, for use with EN 12201-2 HDPE and EN 10217-1 steel pipe. For above and below ground use. Maximum working pressure: SDR7.4 25bar, SDR11 16bar or SDR17 10bar. Maximum operating temperature: Cold water use only.
Range of metric and imperial PVC-U Solvent cement or Threaded fittings for use with PVC-U pressure pipe Class E manufacture to BS EN 1452 Maximum working pressure; 16 Bar Maximum operating temperature; Cold water only
Range of blue epoxy coated ductile iron flanged dismantling fittings. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Range of dual flush WC syphons incorporating polypropylene bodies and stainless-steel C-links. Cold water use only
Range of WC dual flush drop valves with ABS bodies and silicone seals. The valves are operated via a two push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.
Range of water meters with plastic bodies, incorporating stainless steel pipe section. Maximum working pressure 16.0 bar. Maximum operating temperature 23.0°C
Range of ultrasonic water meters with brass bodies and EPDM O-rings. The inlets incorporate a double check valve assembly, verified by test - suitable for backflow protection against Fluid Category 3. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of electromagnetic water meters with stainless steel bodies and natural rubber liners. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.
Range of ultrasonic water meters with brass/plastic bodies. The inlets incorporate plastic strainers and brass spherical ball valves. Maximum working pressure 16.0 bar. Maximum operating temperature 50⁰C.
Range of ultrasonic water meters with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85⁰C.
Range of pressure transmitters gauge pressure measurement devices and differential pressure measurement devices with either stainless steel or Hastelloy or Monel bodies. Maximum working pressure 66.0 Bar Maximum operating temperature 85.0°C
Water shock absorber incorporating a stainless-steel body and EPDM membrane. Maximum working pressure 15.0 bar. Maximum operating temperature 85°C.
Range of heat interface units providing heating and instantaneous hot water. The central heating and hot water is generated via plate heat exchangers. The central heating circuit contains a pressure relief valve (3.0 bar) and an expansion vessel. Max Temperature & Pressure: Primary Circuit: 6.0 bar at 90°C DHW Circuit: 10.0 bar at 55°C Secondary Circuit 6.0 bar at 90°C
Range of multistage centrifugal pumps with stainless steel impellers, intermediate chambers, shaft and outer sleeve. The DPV(M/S) models and DPV(S) models can also incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressures: Existing models: DPV models 10.0 bar, DPVM models with an oval flange or VME models with integral check valve 16.0 bar, All other DPVM models 25.0 bar. DPV(S) models with an oval flange or DPV(S)(E) models with integral check valve 16.0 bar, All other DPV(S) models and DPH(S)I models 25.0 bar. Maximum operating temperatures: DPHM, DPVE and DPVME models with integral check valve 60°C, all other model variants 100°C.
Range of pumps with plastic bodies, plastic impellors and either ceramic (CE suffix models) or graphite (GR suffix models) sleeves. Maximum working pressure 7.0 bar. Maximum operating temperature 85°C.
Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. Maximum operating temperature 35°C.
A range of variable speed booster pumps with stainless steel bodies and impeller. Maximum working pressure: 8 bar. Maximum operating temperature: 35°C.
Range of interlocked EPDM lined shower hoses assemblies with EPDM gaskets. Maximum operating temperature: 85°C Open outlet use only.
Range of shower handsets and headsets with chromium plated plastic bodies. Models P60901 and P61400 have check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum working pressure: Open outlet. Maximum operating temperature: 60.0°C.
Range of fixed shower arms, (brass bodies - various finishes) with EPDM O-Rings. Maximum operating temperature: 85°C, open outlet use only.
Page 407 of 427
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.