Range of flexible hoses assemblies incorporating a braided outer with TPSiV liner and various brass end connections. Maximum operating temperature 85°C. Open outlet use only.
Range of stainless steel or nylon braided, PEX lined flexible hose assemblies with various brass end connections. Maximum working pressure 10.0 Bar. Maximum operating temperature 85 °C.
Stainless steel braided hose incorporating an EPDM liner and NBR ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel, stainless steel with nylon or nylon braided, EPDM lined hose assemblies. Some models incorporate servicing valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies with EPDM seals, available with a variety of end connections. Maximum working pressure: 6.0 bar @ 65°C Maximum working pressure: 12.0 bar @ 20°C
Range of ‘Ridgeline’ stainless steel flexible connectors. Maximum working pressure 6.0 bar. Maximum operating temperature 80°C.
temperature and pressure relief valve set at 7.0 bar@90˚C. A safety kit (manifold) consisting of a check valve cartridge (verified by test, suitable for backflow protection against Fluid category 2) strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish, expansion vessel and a filling loop assembly, incorporating a stainless steel braided EPDM lined flexible hose, brass bodied isolation valve and a DZR brass non-verifiable double check valve assembly that incorporates an isolation valve. Maximum working pressures: Secondary circuit 5.5 bar. Primary circuit 3.0 bar Maximum operating temperature 90.0°C
Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. Fitted with a Caleffi 309463 GLD temperature and pressure relief valve sat at 6 bar & 90°C, and supplied with an inlet control group consisting of in-line pressure reducing valve (Caleffi set at 3 bar) and pressure relief valve (Caleffi CWIC200055) set at 4.5 bar, and incorporates a stainless-steel mesh and an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2), expansion vessel and filling loop. Maximum working pressure 4.4 bar. Maximum operating temperature 99°C.
Range of wall mounted, or concealed manually operated blending valves, (brass bodies – various finishes), incorporating a ceramic cartridge headwork controlling both the flow and temperature with a single lever operating member. Maximum working pressure 5 bar. Maximum operating temperature 85°C.
Range of thermostatic mixing valves with DZR brass bodies. The inlets incorporate a stainless-steel strainer and single check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 10 Bar Maximum operating temperature 85°C
Range of wall mounted, exposed or concealed thermostatic shower valves (chrome plated brass) bodies incorporating a quarter turn ceramic disc headworks with various operating members. Temperature is controlled independently via a thermostatic cartridge also using various operating members incorporating a manual override button. The products incorporate approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of wall mounted, concealed, thermostatic shower valves with (brass bodies – various trim set finishes. Incorporating a quarter turn ceramic disc headwork which controls the flow using dome type operating member. Temperature is controlled independently via a thermostatic cartridge also using a dome type operating member incorporating a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of wall mounted thermostatic shower valves, (brass bodies - various finishes) incorporating a two-way manual diverter headwork controlling the flow to either an overhead shower or shower handset. The temperature is controlled via a thermostatic cartridge incorporating a manual override button. The inlets on the shower valve and shower handset incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted, concealed, thermostatic shower valves with (brass bodies - chrome plated trim sets). Flow is either controlled by a ceramic disc headwork or 3-way manual diverter. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member and a manual override button. The inlets incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provide backflow protection. Maximum working pressure; 10Bar Maximum operating temperature; 60°C.
Range of thermostatic bar shower mixers, (brass bodies – various finishes) incorporating ceramic disc diverter valves with dome type operating members. The temperature is controlled independently via a thermostatic with a dome type operating member that incorporates a manual override button. The inlets incorporate approved single check valve cartridges, however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection. The products are supplied with a shower hose, handset, overhead shower and riser rail assembly. Maximum working pressure 5.0 bar Maximum operating temperature 60°C.
Range of wall mounted thermostatic bar shower mixers (brass bodies – various finishes) incorporating either a quarter turn ceramic disc headwork or two-way ceramic disc diverter with a dome or cubed type operating member. The temperature is controlled independently via a thermostatic cartridge with dome or cubed type operating members that incorporate a manual override button. The inlets incorporate approved single check valve cartridges, however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection. Models ( ET 106, HT 106 & CV 106) are supplied with shower hose, handset, overhead shower and riser rail assembly. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of lever operated butterfly valves incorporating fusion bonded Epoxy coated ductile iron bodies, with stainless steel discs and end faces and EPDM seat. For use with Stainless steel pipe manufactured to EN 10217-7 (or Equivalent). For above and Below ground. Maximum working pressure 16.0 bar Maximum operating temperature 85°C
Wall mounted, concealed, 2-way diverter valve (brass bodies – various finishes) with a dome type operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Wall mounted concealed two way and three way diverter valve assembly (brass bodies with trim sets in various finishes). The 59556 000070 and 59548 000170 concealed installation units are not approved in their own right. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of control valves with plastic bodies, supplied with bypass valves. Maximum working pressure 8.6 bar. Maximum operating temperature 39°C.
Page 344 of 390
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.