Range of wall mounted and overhead shower outlets, incorporating stainless steel strainers and flow regulators at the inlets. Maximum operating temperature 60°C
Shower outlets incorporating chrome plated ABS bodies. Maximum operating temperature 65°C.
Range of shower handsets incorporating plastic bodies (various finishes), plastic flow regulators and stainless steel strainers. Maximum operating temperature 60°C.
Range of shower kits, shower outlets and shower hoses. The shower handsets and overhead shower inlets incorporate a plastic flow regulator. Maximum operating temperature 45°C.
Self-closing tap for drinking water fountains (chromium plated brass) with dome type operating member. The spout outlet incorporates a stainless-steel strainer. The product is supplied with a metal back nut. Maximum working pressure 5.0 bar. Cold water use only.
Range of self-closing taps (chromium plated brass) incorporating spring loaded headworks with dome type operating members. The spout outlet of the 9000 model incorporates a plastic flow straightener. The products are supplied with a metal back nut. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C, except for the 9054SA model which is cold water use only.
Self-closing drinking fountain tap (chromium plated brass) with non-concussive headwork operated via a push button. The tap incorporates a metal shroud and is supplied with a metal back nut. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower hoses incorporating stainless steel interlocking outer with PVC inner liner or PVC outer and PVC inner liner (see model). Maximum operating temperature 65°C.
Range of chromium plated stainless steel or brass interlocked shower hoses with an optional PVC outer layer. Incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
Range of flexible shower hoses incorporating a PVC inner lining, corrugated stainless steel outer layer (various finishes) and silicone washers. Maximum operating temperature 65°C.
Range of shower hoses with PVC outer (various finishes - see model), PET reinforcement layer, PVC inner liner and EPDM washers. Maximum operating temperature 65°C.
Range of interlocking metal shower hoses with silicone liner and EPDM washers. Maximum operating temperature 70°C.
McDonald Steel Flow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Stainless steel indirect thermal store. The primary circuit is factory fitted with a temperature and pressure relief valve (3 bar and 92°C). Hot water storage for space heating via air to water heat pump Maximum working pressure: Primary circuit 3.0 bar Maximum operating temperature 85°C.
SSB, SSI SST range of stainless steel unvented cylinders provided with an unvented kit supplied with cylinders containing a temperature and pressure reducing valve set at 3.0 bar and an expansion vessel and single check valve (suitable for fluid category 2) . Available as storage tank, indirect or twin coil. Maximum working pressure of the cylinder 6.0 bar, maximum working pressure of the coil or coils 12.0 bar. Maximum operating temperature 95°C.
Range of domestic stainless steel indirect unvented hot water storage cylinder incorporating a stainless steel coil for connection to a heat pump circuit. The secondary circuit is factory fitted with a temperature and pressure relief valve (10 bar and 92°C) and an Incoloy immersion heater and magnesium sacrificial anode. Maximum working pressure: Secondary circuit 9.5 bar. Maximum operating temperature 95°C.
Range of wall mounted, concealed, thermostatic shower blending valves with brass bodies and trim sets (various finishes). The temperature is controlled via a thermostatic cartridge with a cross top or single lever operating member. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, thermostatic mixing vales with brass bodies and chrome plated trim sets, incorporating one or two quarter turn ceramic disc headworks with various operating members (see models). Temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork (with various operating members). The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature is 85°C.
Range of water filters cartridges with plastic bodies and either carbon block or activated carbon filter media. Maximum working pressure 8.6 bar. Maximum operating temperature 38°C.
Page 33 of 206
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.