Range of press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of “JRG Sanipex MT” compression fittings with EPDM ‘O’-rings for use with “JRG Sanipex MT ECO” multilayer pipes (PE-RT II/Al/PE-RT II). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of R-154 stainless steel pressed collars incorporating stainless steel bodies (304L or 316L) and are only to be used with stainless steel pipe. Maximum working pressure for sizes up to DN150 (FCM models) or DN125 (FCI models) is 25.0 bar. Maximum working pressure for size DN200 (FCM models) or DN150 and DN200 (FCI models) is 16.0 bar. Maximum operating temperature 99°C.
Silicon Bronze bodies Press Fittings with EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Copper press-fit fittings with copper with EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Indirect heat interface unit with copper brazed, stainless-steel heat exchangers, providing heating and instantaneous hot water. The product incorporates an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the heating circuit set @ 2.5 bar. The DHW and heating circuits are both fitted with drain valves incorporating cover caps. Maximum working pressure 16 Bar (Primary), 10 Bar (DHW) & 3 Bar (Heating) Maximum operating temperature 95°C
‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.
Range of IUW ultrasonic water meters with blue epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature: 50°C.
Range of in-line water meters with brass bodies and plastic turbines. The inlets incorporate plastic filters, and the outlets incorporate non-return valves (not suitable for backflow protection). Maximum working pressure 16.0 Bar. Maximum operating temperature 65.0°C.
Range of wall brackets (brass bodies – various finishes). Open outlet use only Maximum working temperature 85°C
Hydraulic circuit used to control the water path within the heating and sanitary boiler, with plastic body incorporating filter, flow regulator, plate heat exchanger and EPDM O-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 85°C.
Range of single stage booster pumps incorporating a flow switch. Model 46349 CH 12-14 B is supplied with a pressure vessel and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with a strainer and stainless-steel braided EPDM lined flexible connection hoses. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of two, three or four pump booster sets, with vertical multistage pumps comprising of pressure vessels, stainless steel manifolds, pressure gauges, spherical valves and EPDM O-rings. Maximum working pressure - 10.0 bar. Max operating temperature - Cold water use only.
Chrome plated brass shower handset. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of adjustable ceiling and wall mounted shower arms available with brass bodies (various finishes). Maximum operating temperature 85°C.
Wall mounted shower set comprising of an inlet connection, shower handset (brass bodies, various finishes), shower holder and EPDM lined shower hose. Maximum operating temperature 85⁰C.
Range of overhead shower outlets with brass bodies (various finishes). The products incorporate a plastic flow regulator. Models listed are to be used in conjunction with the 26 471 180 basic set. Maximum operating temperature 65°C.
Range of shower outlets comprising of shower heads all incorporating stainless-steel strainer washers (plastic bodies-various finishes) and handheld showers (plastic bodies - various finishes). Maximum operating temperature 75°C.
Range of overhead shower and shower handsets with (brass or plastic bodies – various finishes), incorporating a stainless-steel strainer on the inlets. Open outlet use only Maximum operating temperature – 85°C.
Range of shower arms, (stainless steel bodies – various finishes). Open outlet use only. Maximum operating temperature - 85°C
Page 284 of 390
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.