Range of deck mounted three hole single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporatinig ceramic disc headworks with cross top (14428W-3-CP) or single lever (14428W-4-CP) operating members. The product is supplied with stainless-steel braided EPDM lined flexible hose assemblies to connect the headworks to the spout outlet. Spouts incororate plastic flow straightners. Maximum working pressure 5 bar. Maximum operating temperature 60°C
Range of combined bath fillers and overflow waste assemblies with plastic bodies (various finishes). The outlet incorporates a plastic aerator and the product is supplied with a cable operated pop-up waste. Maximum operating temperature 60°C.
Range of deck mounted, four hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a 2-way ceramic disc diverter headwork controlling the flow between the spout and shower outlet. Temperature is controlled independently by a thermostatic cartridge. The ARR-132T-CP model has single lever operating members and the ARR-232T-CP model has cross top operating members. Each inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset, and has metal backnuts. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Spout outlet, (chrome plated brass body) incorporating EPDM ‘O’ rings. The outlet incorporates a plastic flow straightener.
Non-metallic materials and components comply with BS6920 at 50°C
Range of wall mounted spouts with a brass body (various finishes, see model). The outlet incorporates a plastic aerator. Maximum operating temperature - 60°C
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
Range of copper press fittings with EPDM seals for use with EN1057 copper tube. The joints are achieved by means of a press tool. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
“Inox press-fitting system” range of stainless-steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312 series 2). Joints are achieved using a press fitting tool. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 95°C
‘Buteline Polybutylene Plumbing System’ comprising of DZR brass or plastic fittings for use with Buteline polybutylene, EVOH barrier pipe (white or grey). Maximum working pressure 16 bar @ 23°C, 7.0 Bar @ 82°C.
Range of Gerpex press fittings for use with Alpert multilayer (Pe-rt/Al/Pe-rt) pipe. Alpert Multilyer Composite Pipe and Press Fitting system with brass press fittings with stainless steel sleeves incorporating EPDM o-rings. 16mm to 32 mm are LBP fittings and from 40mm to 63 mm are standard fittings. Joints are achieved via TH profile press tool. Maximum working pressure: 10bar Maximum working temperature: 95°c
Range of copper and brass press-fit fittings with HNBR o-rings, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of DZR brass push fit fittings for use with copper pipe (manufactured to BS EN 1057), PB pipe (manufactured to BS7291-2) and PEX pipe (manufactured to BS7291-3). Maximum working pressures and operating temperatures: 12.5 @ 20°C, and 3.0 bar @ 92ºC.
Range of end feed copper solder fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of dual flush WC drop valves with an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
IR sensor activated dual flush WC siphon valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. Cold water only.
Range of stainless-steel plate heat exchangers. Maximum working pressure 10 bar. Maximum operating temperature 90°C.
‘G5 BC’ range of command centres that provide instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCS’ range of command centres that provide instant near boiling, sparkling and chilled water (all filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products incorporate a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum inlet supply pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCU60 UV’ Command centre that provides instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combinations of solenoid valves and electronic pumps to the outlets. A UV unit is incorporated on the outlet from the chilled water tank. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
Page 246 of 509
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.