Functional trim set (chrome plated), comprising two quarter turn ceramic disc headworks with either single lever (models ending in 882) or cross top (models ending in 892) operating members and a spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (swivel) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks with various operating members and manually operated diverter to a shower hose and handset. The spout outlet incorporates a plastic flow straightener and is also supplied with an optional aerator. The outlet to the shower incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted spout outlets (chrome plated brass). The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum working temperature 60°C.
Range of wall mounted basin spouts (chromium plated brass). The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum operating temperature 60°C.
Wall mounted bath spout outlet incorporating a brass body (chromium plated) and a plastic flow straightener. Maximum operating temperature 60°C.
Range of expansion vessels incorporating composite plastic bodies and butyl diaphragms. Maximum working pressure 8.6 bar. Cold water use only.
Expansion vessels incorporating a stainless steel body and EPDM membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 100˚C.
Range of inline water filter cartridges with polypropylene housing with a carbon block filter. Maximum working pressure 8.5 Bar Cold water use only.
Range of SUS316L & SUS304 stainless steel press fittings for use with stainless steel pipe manufactured to EN 10312. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press fit fittings incorporating copper (GP5 models) or bronze (GP4 models) bodies and EPDM `O`-rings, for use with copper tube to EN 1057. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Unidelta range of compression fittings with polypropylene bodies with EPDM ‘O’ rings for use with PE100 polyethylene pipe (manufactured to EN12201). Maximum working pressure 16.0 bar. Cold water use only.
Range of WC dual flush drop valve comprising of a plastic body, silicone seating washer and an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
Range of WC dual flush drop valves comprising of a plastic body, silicone seal and an internal overflow. The valve is operated via a push button or lever assembly for either full or reduced flush. Cold water use only.
Range of water meters with black epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Copper corrugated hose. Maximum working pressure 10.0 bar. Maximum working temperature 90°C.
Range of plastic bodied quarter turn isolation valves, with EPDM rubber ‘O’-rings, seals and washers. The 52.009.100 model is operated by a hex key (not supplied), the 52.009.200 model is operated by a key (supplied). Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Appliance inlet group assembly comprising of EPDM gaskets, a plastic bodied Y-pattern strainer, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a dual layer hose with a PVC outer (grey) and PVC liner (black), a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of water meter couplings with black plastic bodies. Maximum working pressure 16.0 bar. Cold water use only
Range of hand wash and dryer units The flow is controlled by a solenoid valve activated via an infra-red sensor. The products are supplied with a non-verifiable double check valve assembly (suitable for backflow protection against Fluid category 3) for installation on the inlet. The double check valve assembly also incorporates a drain port, (located in between the cartridges), and an integral spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 50ºC.
Pressure gauge with a plastic case, brass connector and bronze spring tube. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Page 24 of 522
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.