Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes). Incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. The product is supplied with 3/8” x 15mm reducers incorporating approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is to be used with an instantaneous water heater. Maximum working pressure: 10.0 bar Maximum operating temperature: 60°C
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Products incorporate an additional hose outlet and shut-off valve for use with an external domestic appliance. Maximum working pressure: 10.0 bar Maximum operating temperature: 60°C
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Maximum working pressure: 10.0 bar Maximum operating temperature: 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses for models APL1 & ATE1 incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The pull-out spout outlet incorporates a plastic aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses for models Aquaplay single lever Aquanomic & Aquatech single lever Aquanomic incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. The cold inlet hose and the spout outlet incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The pull-out spout outlet incorporates a plastic aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The cold only inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted two hole, single outlet (fixed) combination tap assembly (brass body, various finishes), incorporating ceramic cartridge headwork and single lever operating member. The spout incorporates a plastic aerator. Maximum working pressure: 5.0 bar. Maximum operating temperature: 60°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate an aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure; 10 Bar Maximum operating temperature 65°C
Range of two-hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic discs headworks and single lever or dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
SuperFlow MCPA, MCMA & MCUA ranges of expansion vessels. Maximum working pressures: MCPA Series = 10.0 bar, MCMA Series = 16.0 bar, MCUA Series = 25.0 bar. Maximum operating temperature 65°C.
Inline filter with plastic body. Maximum working pressure 5.0 bar. Cold water use only.
Range of in-line carbon block water filters and housings with polypropylene bodies. Maximum working pressure 8.0 bar. Cold water use only.
A range of black polyethylene electrofusion fittings from DN 20 to DN 1200 for use with PE100 and PE100-RC pipes conforming to EN 12201 or ISO 4427. A range of black polyethylene butt-welded fittings from DE 20 to DE 1200 fittings for use with PE100 and PE100-RC pipes conforming to EN 12201 or ISO 4427. Maximum working pressure: 20.0 bar for SDR 9 Maximum working pressure: 16.0 bar for SDR 11 Maximum working pressure: 10.0 bar for SDR 17. For above and below ground and cold water use only.
‘Safety’ range of PPS compression fittings for use with “Multi-Calor” multi-layered PEX/Al/PEX pipe. For above ground use only. Maximum working pressure 10bar. Maximum operating temperature 95 °C.
‘Pexalbrass’ range of brass press fittings for use with “PEXAL” multi-layered (PE-X /Al/PE-X) pipe. Joints are achieved via crimping tool for H (DN16, DN20, DN26, DN32), TH(DN16, DN20, DN26, DN32, DN40, DN50, DN63), U (DN16, DN20, DN26, DN32, DN40, DN50, DN63, DN75, DN90, DN110) profile. Maximum working pressure 10bar. Maximum operating temperature 95 °C.
Range of brass press fittings (TH and U crimp profiles) for use with RIIFO B1 PEX/AL/PEX multilayer pipe. Maximum working pressure: 10 bar Maximum operating temperature: 95 °C
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use (sizes 12mm-54mm only. 66.7mm, 76.1mm, 88.9mm & 108mm for above ground use only) Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PCC type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of brass threaded fittings,. Above ground use only. Maximum operating pressure of 16.0 bar. Maximum operating temperature of 85°C.
Tectite Classic and Tectite Pro ranges of copper alloy push-fit fittings The Tectite Classic range is for use with copper tube (manufactured to BS EN 1057) and PEX & Polybutylene tube (manufactured to BS 7291). The fittings are supplied with plastic inserts. The Tectite Pro range is for use with copper tube (manufactured to BS EN 1057). Maximum working pressures & operating temperatures: Tectite Classic fittings with copper pipe: 6.0 bar @ 95°C, 16.0 Bar cold water use. Tectite Classic fittings with PEX & Polybutylene 6.0 bar @ 95°C, 12.0 Bar cold water use. Tectite Pro fittings (15mm - 28mm): 6.0 bar @ 95°C, 20.0 Bar cold water use. Tectite Pro fittings (32mm - 54mm): 6.0 bar @ 95°C, 16.0 Bar cold water use.
Float switch with plastic body. Maximum working pressure 1.2 bar. Maximum operating temperature 23°C.
WC dual flush valves with a plastic body and incorporates an internal overflow. Cold water use only.
Range of urinal flushing mechanisms, consisting of a solenoid valve controlling the flow which is actuated via an infra-red sensor. Models are either mains or battery operated and are available in a variety of enclosure options Maximum operating pressure 8 bar. Maximum operating temperature 23°C
Range of near boiling hot water dispensers with stainless steel tanks and flow is controlled via float switch. Maximum working pressure 3 Bar. Maximum operating temperature 98°C.
Range of ultrasonic water meters with brass or stainless steel bodies and plastic or stainless steel transducers. The SC-F models incorporate a spherical valve operated via a motor controlled by computer software. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line water meters with stainless steel bodies Maximum working pressure 10.0 Bar. Maximum operating temperature 50.0°C.
Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve. Models ending in ‘CGDM’ incorporate a single check valve cartridge and models ending in ‘CGDCVDM’ incorporate two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meter manifolds with plastic bodies, incorporating plastic pushfit inlets and plastic pushfit outlets. The inlets incorporate a spherical ball valve. Models MB40408256DCVDM & MB40408254DCVDM incorporate two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16 bar. Cold water use only.
Range of water meter manifolds with plastic bodies, incorporating plastic inlets and gunmetal outlets. The inlets incorporate a spherical ball valve. Models MB40408036CGDCVM & MB40408034CGDCVM incorporate two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16 bar. Cold water use only.
Range of electronic pump controllers with plastic bodies. Maximum working pressure 12.0 Bar. Cold water use only.
Range of pressure transducers with stainless steel bodies. Maximum working pressure 10.0 Bar, 20 Bar or 40 Bar. Maximum operating temperature 99°C.
Range of shower booster pumps with brass bodies and plastic impellers. The body incorporates a single check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure: 4.0 bar. Maximum operating temperature: 70°C.
‘UPM10’ and ‘UPM20’ range of circulator pumps with a stainless-steel body, plastic impellor and EPDM ‘O’-rings. The product is supplied with EPDM gaskets for the inlet and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
'HYDRO MULTI-E' booster set range consisting of two to four electronically controlled pumps connected in parallel and mounted on a common base frame provided with all necessary fittings. The suction manifold incorporates an isolation valve fitted between it and the individual pumps, and a pressure switch with an isolation valve. The discharge manifold incorporates an isolation valve and a non-return valve (not suitable for backflow protection), which is fitted between it and the individual pumps, it also incorporates a combined isolation and drain valve. Maximum working pressure 16.0 bar. Cold water use only.
Self-priming single stage pump, with stainless steel body, plastic impellers, stainless steel shaft, NBR 'O'-rings and seals. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C.
Dutypoint ‘VMV’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. VMV2, VMV3 and VMV4 pump sets are available with DN80 to DN150 manifolds depending on application. VMV5, VMV6, VMV7 and VMV8 pump sets are available with DN150 to DN200 manifolds, depending on application. The products incorporate spherical valves on both the suction and discharge manifolds, with expansion vessels, isolation valves, pressure gauges and transducers on the discharge manifolds only. Maximum working pressure 16.0 bar. Cold water use only.
Range of ceiling mounted shower heads (chrome plated brass bodies). Inlets incorporate plastic flow regulators and single check valve cartridges (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Open outlet use only. Maximum operating temperature 60°C.
Range of shower handsets with ABS plastic bodies (various finishes, see models). Maximum operating temperature (see models).
Page 202 of 226
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.