Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. The primary circuit has a maximum working pressure of 2.5 bar. The secondary circuit has maximum working pressure of 10.0 bar. Maximum supply temperature is 60°C. Maximum operating temperature of secondary circuit is 85°C.
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Hydraulic block assembly comprising a flow sensor, primary pump assembly, pressure relief valve preset at 3.0 bar and plate heat exchanger. Maximum working pressures: secondary = 10.0 bar and primary = 2.5 bar. Maximum operating temperature 80°C.
Aquila V5 range of water meters with black epoxy coated cast iron bodies, plastic turbines, fibre/NBR flange gaskets and either NBR or EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.
Range of ultrasonic water meters with brass bodies incorporating EPDM ‘O’-rings. The inlets incorporate a plastic strainer. The DN15 X 165mm and DN20 X 190mm models incorporate a non-return valve on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meter manifolds (also known as double box valves) for use with MDPE pipe (manufactured to BS EN 12201). The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 16 bar. Cold water use only.
Range of ‘Resident Valves’ with a DZR brass body consisting of water meter manifold, an isolation valve on the inlet, a pressure reducing valve (adjustable between 1.5 and 6.0 bar) and 2 non-return valves which are located on the outlet of the water meter manifold. The ‘Plus’ models are also supplied with an isolation valve on the outlet, which incorporates a drain tap. Maximum supply pressure 16.0 Bar. Cold water above ground use only.
Range of flexible joints incorporating an EPDM (inner & outer) joint with a steel reinforcing ring and two carbon steel flanges. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.

External pump docking station with a plastic body and NBR ‘O’ rings. Cold water use only.
Range of radial flowmeters incorporating EPDM ‘O’-rings. The type 10088400 model has a black plastic body and threaded inlet. The type 10088402 model has a pale olive green plastic body with a threaded brass inlet incorporating a plastic filter. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Plastic bodied flow sensor with silicone gaskets. Maximum working pressure 17.5 bar. Maximum operating temperature 85°C.
Range of in line regulating valves DZR brass bodies, EPDM ‘O’-rings and PTFE seals. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of shower handsets plastic bodies (various finishes) and EPDM ‘O’-rings. All models include a button on the shower face which alters the spray pattern. The product incorporates either a plastic strainer (26 050 & 26 530) or a stainless-steel strainer and a plastic flow regulator (26 051 & 26 531) on the inlet. Maximum operating temperature 60°C.
Shower bracket, incorporating a brass body(various finishes) and EPDM O’-rings. Maximum operating temperature 85°C.
Range of shower handsets incorporating plastic bodies (various finishes). The inlet incorporates an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower outlets: swivel ball joint overhead shower heads with brass bodies (chromium plated) and shower handsets with plastic bodies (chromium plated). The overhead showers incorporate a combined EPDM washer and stainless-steel strainer on the inlet. Maximum operating temperature 65°C.
Range of ceiling mounted shower outlets. The inlet to the shower head incorporates a combined NBR gasket and stainless steel filter, as well as a plastic flow regulator which is located after an adjustable ball joint. Maximum operating temperature 60°C.
Shower handset with plastic bodies (chrome plated). Maximum operating temperature 65°C.
Swivel ball joint overhead shower head with brass bodies (chrome plated). The overhead showers incorporate a combined EPDM washer and stainless-steel strainer on the inlet. Maximum operating temperature 65°C.
Range of shower handsets (chromium plated) brass bodies and NBR O-rings. The inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature 60ºC
A range of shower kits and hand showers incorporating metal bodies (chrome plated). Some models are supplied with sliding rails, wall elbows and shower hoses (see models). Maximum working temperature 60°C.
Range of overhead shower outlets with brass bodies in various finishes (See models) incorporating EPDM ‘O’-rings and seals. The inlet to the shower heads incorporate either a plastic steel sieve (26 031 xxx) or a stainless steel (26 032 xxx) has a stainless-steel sieve. The inlet for the shower head incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection (Model 26 031 xxx only). Maximum operating temperature 60°C.
Range of plastic shower handsets (various finishes). Maximum operating temperature 75°C.
Range of flow switches with plastic bodies. The VK308/10/15/20/25/32/40/50M and VKS08/10/15/20/25/32/40/50M prefix models are supplied with an inline brass adaptor. The VK305/306/309M and VKS05/06/09M prefix models are supplied with a brass adaptor for direct insertion into a pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of bib taps incorporating either brass or DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Pillar tap (chromium plated brass) , incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a stainless steel aerator and the product is supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of self-closing combination taps with brass bodies (chrome plated), incorporating a non-concussive headwork with dome type operating members. The inlets incorporate an approved single check valve cartridge, however the complete assembly has not been verified to demonstrate it provides backflow protection. The inlets of model 28681 incorporate a stainless-steel filter. The inlets of model 28682 incorporate a servicing valve and stainless-steel filter. The outlets of all models incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Self-closing tap (chromium plated brass) incorporating spring loaded headworks incorporating a dome type operating member, with a single lever operating member controlling the temperature. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate a check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
‘OH RPE’ Range of PE-RT (multi-layer) flexible hoses (white inner/silver outer). The following end connections are available with one or two approved single check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection: CQC (one) and SQC (one or two). Maximum operating temperature 65°C.
PEX lined flexible hose assemblies with either nylon or stainless-steel braiding and a variety of end connectors. Some models are supplied with screwdriver operated isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
OH Softpex® range of polyethylene lined outlet hoses with stainless steel and polyamide braiding (length 100 to 1000 mm), with various end connections. The hose incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 65°C.
EPDM lined flexible hose assemblies with either nylon or stainless-steel braiding and a variety of end connectors. Some models are supplied with screwdriver operated isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of indirect and direct unvented storage cylinders consisting of either no coil (GLE) or a factory fitted single (GLC) or twin coil (GLT). The secondary circuit is supplied with a temperature and pressure relief valve set at 7.0 bar@85˚C for 1.0-6.0 bar products and 10.5 bar@95°C for 6.0-10.0 bar products. The products are supplied with an inlet control group (safety kit) consisting of a pressure reducing valve, an expansion relief valve 6.0 bar (1.0-6.0 bar products) or 10.5 bar (6.0-10.0 bar products) and an approved check valve, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is also supplied with an expansion vessel. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of free standing direct gas fired unvented cyliners with a enamel coating internal lining and magnesium sacrificial anode. Fitted with a combined temperature and pressure relief valve set at 7 bar. Maximum working pressure 6.5 bar. Maximum operating temperature 80°C.
Range of two, three, four and five-way manifold assemblies incorporating brass bodies (brushed chrome finish) and EPDM ‘O’-rings. The products are supplied with isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of wall mounted, concealed, blending valve, incorporating brass bodies (chrome plated), quarter turn ceramic disc headworks with single lever operating members and a manual diverter diverting the flow to two outlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Wall mounted, bar type, thermostatic shower blending valves (chromium plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted bar type thermostatic shower valve, with a ceramic cartridge headwork controlling the flow between overhead shower and handset with a dome type operating member incorporating a manual override button. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a strainer and a single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Supplied with hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Concealed, thermostatic shower blending valve, incorporating a brass body and a (chrome plated) functional trim set. The functional trim set comprises of two detent headworks (push to on, push to off) as the main flow control for each shower outlet, a ¼ turn ceramic disc valve with a dome type operating member controlling the flow volume, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The functional trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. These assemblies are to be inserted into the concealed body. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed, thermostatic shower blending valves, incorporating a brass body and a (chrome plated) functional trim set. The functional trim set comprises of a quarter turn ceramic disc headwork, or a 2 or 3 way ceramic disc diverter headwork (see model) with a dome type operating member controlling the flow, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The functional trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Concealed, thermostatic shower blending valve, incorporating a brass body and a (chrome plated) functional trim set. The functional trim set comprises of a 2 way ceramic disc diverter headwork with a dome type operating member controlling the flow, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The functional trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower panels. Model TFP3001 incorporates a single sequential headwork which controls the flow and temperature using a single lever operating member with an addtional self-closing headwork with dome type operating member which also controls the flow to a fixed shower head. Model TFP3002 incorporates a single sequential headwork which controls the flow and temperature using a single lever operating member to a fixed riser rail shower hose and handset. Model TFP3003 incorporates a self-closing headwork which controls the flow using a dome type operating member to a fixed shower outlet, temperature is pre-set using a thermostatic valve. The inlets on all models incorporate single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with stainless steel strainers, flow restrictors and isolation valves. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, thermostatic shower blending valves with brass bodies and trim sets (chrome plated). Incorporating a thermostatic cartridge headwork with cubed or dome type operating members. The inlets incorporate a flow regulator and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic blending valves with brass bodies (chrome plated), incorporating a manual diverter to two outlets with an off position (model XB-AZ-037A), two ceramic disc headworks controlling the flow to both outlets (model XB-AZ-035A) or one outlet controlled via a ceramic disc headwork (model XB-AZ-034A). The temperature is controlled via a thermostatic cartridge with various operating members (see models). Inlets incorporate stainless-steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of double flanged and wafer type butterfly valves with cream epoxy coated cast iron bodies, EPDM seats and a range of discs (see models). Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.
Range of wafer and lugged type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs and EPDM seat. The closing mechanism can be controlled by either a lever, gear or bore shaft. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of combined temperature and pressure relief valves incorporating DZR brass bodies, EPDM ‘O’-rings and silicone seat washers. The vales are pre-set at 4.0, 6.0, 7.0 or 10.0 bar (see model). The valves incorporate a manually operated rotational easing gear. Maximum operating pressure 10.0 bar. Maximum operating temperature 90°C.
Range of piston type float operated inlet valves with brass bodies. The valves discharge from a downwards atmospheric discharge arrangement on the underside of the body. Maximum working pressure: 3.0 (1FVA106 & 1FVA104 models only) or 14.0 Bar (all other models) Cold water use only.
Piston type float operated inlet valves with blue epoxy coated ductile iron bodies. The products are supplied with a plastic float and carbon steel (galvanised) lever. The valves discharges from a downwards atmospheric discharge arrangement on the underside of the body. Maximum working pressure 16.0 bar. Cold water use only.
Page 17 of 177
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.