Wall mounted, manually operated concealed blending valve, incorporating ceramic cartridge headwork with single lever operating member. The valve incorporates copper pipe which connects the inlets and outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Wall mounted, manually operated blending shower valve with (brass bodies - various finishes) incorporating a ceramic cartridge headwork and a single lever operating member. The shower outlet connection incorporates an approved single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 70.0°C
Range of wall mounted thermostatic bar shower mixers (chrome plated brass bodies), incorporating a quarter turn ceramic disc headwork controlling the flow with cubed or dome type operating members. The temperature is controlled independently via a thermostatic cartridge with dome or cubed type operating members that incorporate manual override buttons. The inlets incorporates approved single check valve cartridges (however, the complete product has not been fully tested to demonstrate that it provides backflow protection). Products are supplied with a shower handset, shower hose, overhead shower and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic shower valves (chromium plated brass) incorporating a single sequential headwork controlling both flow and temperature with a single lever operating member. The products are supplied with 15mm compression inlet elbows incorporating approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets also incorporate plastic flow regulators. The 90033CP model can have either a top or bottom outlet, which is achieved by re-positioning the blanking plug and threaded outlet. The compression connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
A range either concealed or exposed wall mounted thermostatic mixing valves with brass bodies (exposed models are chromium plated). Incorporates ¼ turn ceramic disc headworks. The inlets of all models expect F3004 incorporate stainless steel filters and approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum working temperature 60°C.
Thermostatic blending valve, (DZR brass body – nickel plated). The inlets incorporate an approved check valve cartridge, however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 50°C.
Range of wafer, lug type and double flanged butterfly valves incorporating blue epoxy coated ductile iron bodies, either stainless steel (CF8 or CF8M) or blue epoxy coated ductile iron discs and an EPDM seat. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of wafer and lugged butterfly valves with blue epoxy coated ductile iron bodies and stainless steel disc. DN50-DN300 are lever operated and DN350 – DN600 are handwheel operated. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of handwheel & gear operated butterfly valves with blue epoxy coated ductile iron bodies and discs and EPDM rubber seat. Maximum working pressure 16.0 bar. Cold water use only. Maximum operating temperature 85°C (from Sept 2021)
Wall mounted concealed shut off valve with brass body incorporating a non-rising spindle headwork. Maximum working pressure 10.0 Bar Maximum operating temperature 80.0°C
Range of bronze swing gate valves incorporating a bronze disc with a metal-to-metal seal. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of spherical valves with nickel plated brass bodies, chromium plated brass balls and various operating members (see models). Products incorporate EPDM O-rings and PTFE seats. Maximum working pressure ½” – 1” 30 bar, 1 ¼” – 2” 25 bar. Maximum operating temperature 100°C.
Range of ball valves with DZR brass bodies and either a chrome plated DZR brass ball (¼-1" sizes) or stainless-steel ball (1¼-2" sizes). The valves are available with lock shield, butterfly or single lever operating members. The threaded end connections have octagonal spanner flats. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of lever operated spherical valves with brass bodies (chromium plated), incorporating chromium plated balls and PTFE seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spherical valves with nickel plated brass bodies, incorporating PTFE seats and chromium plated brass balls. Valves are operated by butterfly type handles. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of spherical valves with stainless steel bodies, chrome plated brass ball and PTFE seats. Maximum working pressure 68.9Bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of spherical valves with DZR brass bodies, chrome plated DZR brass or stainless-steel balls, EPDM ‘O’ rings and PTFE seat. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of lever or butterfly operated spherical valves with DZR brass body and ball. Maximum working pressure: 40.0 Bar Maximum operating temperature 99.0°C
Range of lever or butterfly operated spherical valves with brass, DZR brass or nickel-plated brass. Incorporating brass or nickel-plated brass ball. For use with copper pipe BS EN 1057. Maximum working pressure 25.0 Bar. Maximum operating temperature 99.0°C
Range of lever or butterfly operated spherical valves with brass or nickel plate bodies and ball. Maximum working pressure: Various – see model section. Maximum operating temperature 99.0°C
Range of lever operated spherical valves with DZR brass or stainless-steel bodies and ball. Models beginning with ‘GP’ and ‘GPH’ are for use with copper pipes (manufactured to EN 1057). Models beginning with ‘GPMS’ and ‘GPHS’ are for use with stainless steel (SS316L) pipe (manufactured to EN 10312). Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of gate valves incorporating either rising or non-rising spindle headworks and PTFE gaskets. The products have a Bronze body, bronze wedge and handwheel operating member. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of non-rising resilient stem seated gate valves with epoxy coated bodies and EPDM wedge. Maximum working pressure 16 bar. Cold water use only.
Range of non-rising spindle gate valves with bronze, brass or DZR brass (MV40-1116) bodies, incorporating hand wheel or key operated operating members. Maximum working pressure 16.0 Bar (MV40-1153) 25.0 bar
Non-metallic materials and components comply with BS6920 at 85°C
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM wedges. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating blue epoxy coated ductile iron bodies, epdm coated ductile iron wedges, EPDM gasket and seal. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with brass bodies and stems, EPDM O-rings, with non-rising spindles with hand wheel operating members. Maximum working pressure 20.0 bar. Maximum operating temperature 100°C.
Range of bedpan washing & disinfection machines. The flow is controlled by a solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure - See models Maximum operating temperature - 90 °C
Range of commercial washing machines with flow controlled by solenoid valves and discharged via type AB air gap assembly (verified by test - suitable for backflow protection against fluid category 5). The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
Range of inline water conditioners with stainless steel bodies and catalytic alloy core. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Electrolytic scale reducer, with a chromium plated copper body and zinc alloy anodes, for use with copper pipe (manufactured to BS EN1057) Maximum working pressure 10.0 bar. Cold water use only.
Range of electrolytic scale reducers, with a chromium plated copper body and zinc alloy anodes. Maximum working pressure 5.0 bar. Cold water use only.
'JERLAC Bituminous sealer coat black'. Factory applied, black coloured Bitumen coating. Apply as per manufacturer's TDS reference 'BN433', dated '27/07/2023', revision '00'. Cure for 12 hours@30°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hempathane PW 35660 blue & off-white`. Factory applied, two-component polyurethane liquid coating consisting of a base and curing agent. Mix base and curing agent in a 3:1 volume ratio and apply as per product data sheet dated December 2023. Cure for 7 days@20°C. For use with water up to 35°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Transpoxy Guard 472'. Factory applied, two-part, creamy white coloured epoxy resin coating. Mix base and hardener in a mass ratio of 4:1 and apply as per manufacturer's TDS dated 'January 2017'. Cure for 7 days@23°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'XX-CM Sulphate Resisting Cement'. Factory applied, grey coloured cement mortar. Mix cement:sand:water in a 1.0:2.0:0.4 weight ratio and apply as per manufacturer's TDS '004', dated '2023.02.01'. Air cure for 4 hours at 23°C and the vapour cure for 6 hours at 60°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'XX-CM5 Blast Furnace Slag Cement'. Factory applied, grey coloured cement mortar. Mix cement:sand:water in a 1.0:2.0:0.4 weight ratio and apply as per manufacturer's TDS '002', dated '2023.02.01'. Air cure for 4 hours at 23°C and the vapour cure for 6 hours at 60°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Sikafloor® P 649 and Sikalastic® M 649 Coating'. Factory applied, grey coloured (once mixed), two-component primer (non-water contact primer) and two-component coating (water contact coating). Mix and apply Sikafloor® P 649 primer as per Product Data Sheet ‘MBS_CC-UAE/Sl_P_649_04_24’. Cure for 2 hours@25°C. Then mix and apply Sikalastic® M 649 Coating as per Product Data Sheet ‘MBS_CC-UAE/Sl_M_649_06_21/v3/01_24/v4/03_24’. Cure for 1 minute@25°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'PM6/35/7153'. Factory applied, grey coloured enamel coating. Apply as per manufacturer's data sheet RTU version '01-2018'. Cure for 8 minutes@860°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified then the material is not covered by the scope of the approval.
'PP8000 M62091'. Factory applied, blue coloured enamel coating. Apply as per manufacturer's data sheet version '01-2018'. Cure for 7 minutes@840°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified then the material is not covered by the scope of the approval.
'JERLAC Solventless Epoxy Grey'. Factory applied, grey coloured, two-component Epoxy coating. Mix Base:Curing Agent in a 2:1 volume ratio and apply as per manufacturer's TDS reference 'BN434', dated '24/07/2023', revision '00'. Cure for 7 days@30°C. For use with water up to 85°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Wanan brand WA F 501'. Factory applied, blue coloured epoxy powder coating. Apply as per 'Wanan Industry Group Co., Ltd.' TDS 'WATDS20200801a' dated 'Aug. 1, 2020'. Cure for 20 minutes@200°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'E0-850-5210-001'. Factory applied, blue coloured epoxy powder coating. Apply as per 'Ziac Trattamenti Metallici SNC' instructions 'nr.01, rev.00, issue 01' dated 01/082016. Cure for 30 minutes@210°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'MS 520B'. Factory applied, dark grey coloured enamel coating. Apply as per manufacturer's instructions 'ref. PRO PR 15 Gi 01 UK' dated April 04, 2024. Cure for 10 minutes@850°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Sikagard®-180’. Site applied, grey coloured, two-component epoxy coating consisting of Part A (grey coloured liquid) and Part B (colourless liquid). Mix Part A and Part B in a mass ratio of 87:13 and apply as per manufacturer's TDS 'MBS_CC-UAE/Pr_180_05_18/v9/02_22/v10/05_23/v11/01_24'. Cure coat 1 for 36 hours@20°C. Cure coat 2 for 21 days@20°C. For use with water up to 40°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'LOCTITE® SF 770™' (known as 'LOCTITE 770'). Site applied, clear cyanoacrylate primer. Apply as per manufacturer's technical data sheet dated May 2021. Cure for 30 seconds@20°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Subcote FLP II’. Site applied, two-component, green coloured (once mixed and applied) Polyurethane coating. Mix parts A & B in a 100:72 weight ratio and apply & then flush as per manufacturer's IFU 'IFU_Subcote FLP II_In-Situ Pipes_Issue 7_210921 RS EN'. Cure for 1 hour@3°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Sikadur-Combiflex® SG System’ comprising of ‘Sikadur® 31 DW’ epoxy adhesive to be used in conjunction with ‘Sika Combiflex® SG Membrane’. ‘Sikadur® 31 DW’ is a site applied, grey coloured, two-part epoxy adhesive consisting of Part A (white coloured) and Part B (black coloured). Part A and Part B are mixed in a weight ratio of 3:1, applied and cured for 14 days@30°C. ‘Sika Combiflex® SG Membrane’ is a modified flexible Polyolefin (FPO) waterproofing tape to be applied over the adhesive and is approved as the water contact layer. Apply as per ‘Sikadur-Combiflex® SG System’ System Product Data Sheet, ‘Edition: 24/10/2012, Identification no: 02 07 03 02 System, Version: GCC’. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Therma-Light Touch Up Paint'. Site applied, black coloured coating. Apply as per manufacturer's TDS 'TDS/CLP-L 44', dated '28/2/2024'. Cure for 7 days@22°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Sikagard®-1814 - RAL 7035’. Site applied, grey coloured (once mixed), two-component epoxy polysulfide resin coating. Mix Part A (light grey, opaque liquid) and Part B (light yellow, translucent liquid) in a 78:22 weight ratio and apply 2 coats as per manufacturer’s TDS ‘MBS_CC-UAE/Pr_1814_06_23/v1/01_24’. Cure coat 1 for 9 hours@25°C. Cure coat 2 for 14 days@25°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 158 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.