Universal plastic compression adaptor kits for use with SAB A16 fitting body (not included as part of this approval) and galvanised steel pipe (manufactured to EN 10255). Maximum working pressure 16 bar. Cold water use only.
Allpex range of end feed capillary fittings and brazing fittings for use with copper tube (manufactured to BS EN 1057). EG fittings have gunmetal bodies, ED fittings have DZR brass bodies & EB fittings have brass bodies. For above ground use only. Maximum working pressure: 6mm – 34mm 25Bar, 34mm -54mm 25Bar, 54mm – 108mm 16Bar, 108mm – 159mm 5 Bar. Maximum operating temperature 30°C
Range of dual flush WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of dual flush syphonic WC flush valves. Cold water use only.
Range of dual flush syphonic WC flush valves. Cold water use only.
Dual flush, WC outlet valves. Model A2706 is operated via a push button assembly for either full or reduced flush. Maximum operating temperature. Cold water use only.
Range of direct fired water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of direct gas fired condensing storage water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of solar assisted direct gas fired condensing storage water heaters with an enamel lining and a titanium anode incorporating a solar heat exchanger (max. working pressure 6,0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of indirect water heaters with an enamel lining, a magnesium sacrificial anode and single wall spiral heat exchanger (maximum working pressure 6.0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 7.0 bar. Maximum operating temperature 80°C
Range of direct gas fired condensing water heaters with a stainless steel body. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of stainless steel lined direct water heaters fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of direct gas fired condensing water heaters with a stainless steel body. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of direct fired water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of stainless steel lined direct water heaters fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of indirect water heaters with an enamel lining, a magnesium sacrificial anode and single wall spiral heat exchanger (maximum working pressure 6.0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 7.0 bar. Maximum operating temperature 80°C
Range of direct gas fired condensing storage water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C
Range of wall mounted combination boilers providing domestic hot water (DHW) via a plate heat exchanger and pressurised central heating (CH) system. Incorporating a pressure relief valve set at 3.0 bar and expansion vessel. Supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressure Primary circuit (CH) 2.5Bar, Secondary circuit (DHW) 10.0 Bar Maximum operating temperature 90.0°C
Octave range of water meters with blue epoxy coated cast iron or plastic bodies (see models). Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C
Page 148 of 204
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.