WC flushing cistern incorporating a side entry BS 1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of single hole, single outlet over the rim (swivel nozzle) bidet combination tap assemblies with brass bodies (various finishes – see models), incorporating quarter (L & F models) or half turn (H models) ceramic disc headworks with a cross top or lever operating members. The spout outlets incorporate plastic aerators. Maximum working pressure 5.0 Bar. Maximum operating temperature 60.0°C.
Single hole, single outlet, swivel bidet combination tap assembly (chromium plated brass), with a ceramic cartridge headwork and single lever operating member. The spout outlet has a plastic aerator. Product is supplied with lever type pop-up waste. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Quarter turn ceramic disc headworks with brass bodies and NBR ‘O’-rings. Maximum working pressure 10.0bar. Maximum operating temperature 85°C.
Single hole, single outlet, pull-out spray combination tap assemblies incorporating brass body (two finishes) and a ceramic cartridge headwork with single lever operating member. The pull-out spray spout outlets swivel and incorporate a plastic aerator. The inlet to the tap and the spout outlet incorporate a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout is a pull-out spray type incorporating a push button and plastic aerator. The connection to the pull-out hose incorporates an approved single check valve cartridge, however, the whole product has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 5.0 Bar. Non-metallic materials and components comply with BS6920 at 65°C
Range of single hole, single outlet (swivel) combination tap assemblies with (brass bodies -various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator.and a pull out spray feature. The connection between the outlet and the hose incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate that it provides backflow protection Maximum working pressure 7 bar. Maximum operating temperature 65ºC.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate either a plastic aerator or flow straightener (see models) Model: 62783-7301, the inlets incorporate a plastic flow regulator. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever or dome type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets of F9406M and F9406M-** incorporate a plastic aerator. F8122B, F8122B-**: Maximum working pressure - 5.0 Bar. Maximum operating temperature 85°C. F9406M, F9406M-**: Maximum working pressure - 10.0 Bar.Maximum operating temperature 65.0°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 65°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with an optional plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with an optional plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies incorporating ¼ turn ceramic disc headworks and single lever type or dome operating members. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of two-hole, single outlet (fixed) combination tap assemblies, (Chrome plated brass bodies) incorporates quarter turn ceramic disc headworks with single lever operating members and the spout incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 6.0 Bar Maximum operating temperature 65.0°C
Range of two-hole, single outlet (fixed) combination tap assemblies (brass bodies. Incorporates a non-rising spindle headworks with dome type operating members. The spout outlets incorporate a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 6.0 Bar. Maximum operating temperature 65.0°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. Model 62637-5101, the spout outlet incorporates a plastic aerator. Supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks or ceramic cartridge headwork (Model F5135 only) with single lever operating members. The products incorporate either an open outlet type spout or aerator in the outlet (see models). The products are supplied with metal backnuts. Maximum working pressure 8 Bar Maximum operating temperature 65.0°C
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator, and the products are supplied with metal backnuts. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of two hole, single outlet (fixed), combination tap assemblies with (brass bodies - various finishes) incorporating quarter turn ceramic disc headworks with single lever or dome type operating members (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Page 127 of 214
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.