Three-hole, single outlet (fixed) combination tap assembly (brass body – various finishes). Incorporating quarter turn ceramic disc headworks with various operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with a lever type pop-up waste and stainless steel braided EPDM lined connection hoses. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Three-hole, single outlet (fixed) combination tap assembly (brass body – various finishes). Incorporating quarter turn ceramic disc headworks with various operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with a lever type pop-up waste and stainless steel braided EPDM lined connection hoses Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Three-hole, single outlet, (fixed) wall mounted combination tap assembly (brass body – gold effect finish) incorporating two quarter turn ceramic disc headworks with single lever operating members. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted, concealed, three-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of three-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The product is supplied with stainless steel braided PEX lined flexible connecting hoses incorporating ½” BSP captive nut end connections. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of three-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The product is supplied with stainless steel PEX lined flexible connecting hoses incorporating ½” BSP captive nut end connections and a click type pop-up waste. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted, three-hole, single outlet, combination tap assemblies, (brass bodies - various finishes) incorporating ceramic cartridge headworks with various operating members. The spout incorporates a self-cancelling diverter to shower outlet and plastic aerators. The spout inlets incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow prevention. The products are supplied with a shower hose and handset. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Pre-rinse assembly incorporating an interlocked flexible hose and trigger mechanism. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Wall mounted spout outlet with brass body (various finishes) incorporating a plastic aerator. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of spout outlets with (brass bodies - various finishes), incorporating an plastic aerator. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of expansion vessels with a butyl membrane. Maximum working pressure 10 bar. Maximum operating temperature 99°C
Filling loop assemblies consisting of a stainless steel braided EPDM lined flexible hose, an isolation valve and another isolation valve incorporating a non-verifiable double check valve assembly, verified by test (suitable for backflow protection against fluid category 3). The FL12041515 model is supplied with an isolation valve including a dial type pressure gauge. The FL12041525 model is also supplied with brass end caps incorporating EPDM washers. For use with coper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Filling loop assemblies consisting of a stainless steel braided EPDM lined flexible hose, an isolation valve and another isolation valve incorporating a non-verifiable double check valve assembly, verified by test (suitable for backflow protection against fluid category 3). The 171293 model is supplied with an isolation valve including a dial type pressure gauge. The 171292 model is also supplied with brass end caps incorporating EPDM washers. For use with coper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of water filters comprising of plastic filter heads and plastic filter cartridges. Maximum working pressure 5.0 bar. Cold water use only.
The “TH Instantor” range of press fittings and pipe. Fittings incorporate EPDM ‘O’-rings Maximum working pressure 10 bar. Maximum operating temperature 95°C
Range of solder ring brass fittings for use with copper tube (manufactured to EN 1057) with EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of plastic push-fit fittings (available in black, white and grey) and a manifold (available in grey only) with EPDM or NBR ‘O’-rings. For use with copper pipe (manufactured to EN1057), PE-X pipe (manufactured to BS7291-3:2010) & PB pipe (BS EN 21003-2:2008). Maximum working pressure: 12.5 bar @ 20°C (Cold water use only). From September 2023 the products are suitable for 8.0 bar @ 65°C.
Range of end feed copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed brass fittings for use with copper tube (manufactured to EN 1057). Incorporates an EPDM washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube to EN 1057. The HLDPMFWT and HLDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Dual flush, WC outlet valve, operated via a push button assembly for either full or reduced flush and the valve incorporates an internal overflow. Cold water and open outlet use only.
Range of WC pressure flushing valves with a time flow direct flush valve controlling the flow. The valves are operated via a push-button assembly. The valve also incorporates a lever operated isolation valve. Maximum working pressure - 5 Bar Cold water use only.
Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of in-line ultrasonic water meters with DZR brass bodies. The following sizes only include a plastic strainer, DN15 - DN32 sizes (incorporated), DN40 size (optional). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Ultrasonic water meter with a brass body. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Water meter manifold with a DZR brass body, NBR ‘O’-rings and incorporates a spherical valve. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 80°C
Range of single or manifold below ground meter boxes. The boxes incorporate a concentric water meter manifold and a servicing valve on each connection. CV models incorporate an approved single check valve cartridge and the DCV model incorporates two approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The pushfit inlet and outlet connections are supplied with pipe inserts and are for use with MDPE pipe (manufactured to EN 12201). Maximum working pressure 16.0 bar. Cold water use only.
Talbot Modular Manifold System with and without concentric water meter connections with plastic bodies incorporating screw down stopvalves. Maximum working pressure 16 bar. Cold water use only.
KHS range of dynamic flow distributors (gun metal bodies) with spherical valves. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of wall fixing brackets available in chrome and matte black finishes. Maximum working pressure 10 bar. Maximum operating temperature 85°C
Non-metallic materials and components comply with BS6920 at 85°C
Range of pressure transmitters with stainless steel bodies and an EPDM ‘O’-ring. Maximum working pressures 50.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of differential pressure switches with brass or stainless steel (N suffix models) bodies. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 80°C
PET braided, PE/EPDM lined ‘Motion hose’, available in a range of lengths. Maximum operating temperature 70°C.
Pull-out hose assembly consisting of a chromium plated brass 45° elbow connector, a chromium plated brass HDPE lined shower hose and a nylon braided HDPE lined connecting hose. Maximum operating temperature 65°C.
Range of booster pumps with plastic bodies and impellers, stainless steel shafts, brass manifolds, NBR ‘O’-rings and EPDM seals. The product incorporates a pressure vessel. The outlet(s) incorporate(s) an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The inlet hose(s) supplied with this product incorporate(s) an isolation valve. Maximum working pressure 4.0 bar. Maximum operating temperature 65°C.
Range of cold water supply booster sets, consisting of between 2 & 4 pumps, modular stainless steel manifold system, servicing valve, non-return valve (not suitable for backflow protection) and an expansion vessel. Maximum working pressure 10.0 bar or 16.0 bar (identified on adhesive label on expansion vessel) Cold water use only.
Range of circulator pumps with brass bodies, plastic impellor, and EPDM ‘O’-rings and seals. The COMFORT 15-14 BX prefix models incorporate a screwdriver operated isolation valve on the inlet and a non-return valve at the outlet. These are housed within 1” BSP (M) x ½” BSP (M) adaptors. Maximum working pressure 10.0 Bar. Maximum operating temperature 95°C.
Range of multistage pumps (VL and CL series) and submersible pumps (VN, CN, ES and CS series) with stainless steel bodies and impellers and NBR gaskets and ‘O’-rings. Maximum working pressure 15.0 bar (VL and CL series pumps only).
Range of stainless-steel interlocked shower hoses and handsets (chrome plated plastic). Model 27803845 is supplied with a wall elbow (chrome plated brass body) and incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Shower hand set incorporates an approved shower handset, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Shower handset incorporating a plastic body. The inlet incorporates a plastic flow reducer & stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower outlets, comprising of overhead showers and a shower handset (chrome plated plastic bodies). Models 88500077 Amber 2, 88600025 Kelsey 2 & 88600027 Isable 3 have a maximum operating temperature of 65°C. Model 88600042 has a maximum operating temperature of 60°C.
Range of shower handsets and shower heads with chromium plated plastic bodies. The shower heads incorporate a stainless steel strainer. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of showerheads and shower handsets with chromium plated ABS bodies. Showerheads incorporate a stainless-steel strainer. Open outlets use only.
Non-metallic materials and components comply with BS6920 at 65°C
Range of overhead shower outlets (chromium plated ABS plastic bodies). Incorporating a EPDM washer (P29900 only) or combined EPDM washer and stainless-steel strainer on the inlet (all other models). Model P44700 also incorporates a plastic flow restrictor at the inlet. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of showers handsets with plastic bodies (chromium plated, matt black for model P75502). Model P86300 is supplied with an optional flow restrictor. Model P60901 & P70400 incorporates an approved single check-valve at the inlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
‘Axor’ wall mounted shower outlet (brass body – various finishes). The shower outlet incorporates an approved check valve cartridge; however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum operating temperature 70.0°C
Range of shower handsets with plastic bodies (various finishes - see model). The inlet incorporates a combined EPDM washer and stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 65°C
Range of ceiling or wall mounted shower outlets, (brass or stainless-steel bodies - various finishes) incorporating EPDM `O` rings. Maximum operating temperature 60.0°C
A range of ceiling mounted and wall mounted shower outlets (brass and stainless-steel bodies - various finishes) incorporating EPDM O-rings.
Non-metallic materials and components comply with BS6920 at 60°C
Page 112 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.