Expansion vessels incorporating a stainless steel body and EPDM membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 100˚C.
Filling link assembly, incorporating a sliding manifold with EPDM ‘O’-rings, isolation valves and an isolation valve with a double check valve assembly (verified by test as suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Cold water use only.

Range of filling loop assemblies consisting of an in-line isolation valve, in-line double check valve assembly which also incorporates an isolation valve (suitable for back flow protection against fluid category 3) and stainless steel braided EPDM lined hose. The isolation valves are operated via a single lever. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of press fittings incorporating brass or PVDF bodies and EPDM ‘O’-rings. For use with Henco standard PE-Xc/AL/PE-Xc pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of press fittings incorporating stainless steel bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use (sizes 12mm-54mm only. 66.7mm, 76.1mm, 88.9mm & 108mm for above ground use only) Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of compression fittings incorporating polypropylene bodies, plastic pipe liners, plastic grip rings and EPDM seals. For use with both PE80 & PE100 pipe manufactured to BS EN 12201. For above and below ground use. Maximum working pressure 12.5 bar (PE80 pipe 20mm - 63mm). Maximum working pressure 16.0 bar (PE100 pipe 20mm - 63mm). Maximum working pressure 10.0 bar (PE100 pipe 75mm - 110mm). Cold water use only.
Range of crimp fittings with a bronze body incorporating EPDM O-rings. For use with copper pipe manufactured to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C

Range of press fit fittings incorporating copper (GP5 models) or bronze (GP4 models) bodies and EPDM `O`-rings, for use with copper tube to EN 1057. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Unidelta range of compression fittings with polypropylene bodies with EPDM ‘O’ rings for use with PE100 polyethylene pipe (manufactured to EN12201). Maximum working pressure 16.0 bar. Cold water use only.
Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single and dual flush WC outlet valves with ABS body and EPDM seating washers. The valve incorporates an internal overflow and is operated via a push button assembly for either full or reduced flush. Cold water use only.
Dual flush WC outlet valve with ABS body and EPDM seating washers. The valve incorporates an internal overflow and is operated via a push button assembly for either full or reduced flush. Cold water use only.
Range of flow meters incorporating black epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of compact wall outlet assemblies with plastic bodies (chromium plated) and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.
Concealed wall insulation unit with a brass body and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of plastic bodied quarter turn isolation valves, with EPDM rubber ‘O’-rings, seals and washers. The 52.009.100 model is operated by a hex key (not supplied), the 52.009.200 model is operated by a key (supplied). Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Appliance inlet group assembly comprising of EPDM gaskets, a plastic bodied Y-pattern strainer, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a dual layer hose with a PVC outer (grey) and PVC liner (black), a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Appliance inlet group assembly comprising of an EPDM gasket, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a flexible reinforced hose assembly with a PVC lining and a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 5.0 bar. Cold water use only.
Page 2 of 118
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.