Range of PVC-U double union ball valves incorporating EPDM O-rings. Maximum working pressure 16.0 bar. (Cold water use only).
Range of gate valves incorporating bronze bodies and wedges with PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating a blue epoxy coated ductile iron body. EPDM coated ductile iron wedges and a non-rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 45°C. As of September 2024 Maximum operating temperature 23°C.
Angled stop valve with a chrome plated brass body and NBR ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of screw down stop valves with plastic bodies to be used with PEX, MDPE and copper pipe. For above ground use only. Maximum working pressure 16.0 bar, cold water use only.
Front loading, commercial washing machine. Flow is supplied via solenoid valves and the unit incorporates a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
'Dicoat Medium Temp Black'. Factory applied, black coloured bitumen coating. Apply as per manufacturer's user instructions reference 'SPL/RD/UI/2019100121', issue no. '01' dated 08.07.2020. Cure for 7 days@30°C. Between 1st January 2021 to 22nd November 2021, the material is for use with water up to 50°C. Between 23rd November 2021 and 31st January 2026, the material is for use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'RS-0004'. White coloured, compression moulded seal ring manufactured from 'ADR 96' ceramic material. For use with water up to 85°C.
'High Build Solvent Free Epoxy Coating Red'. Factory applied, red coloured epoxy coating. Apply as per manufacturer's user instructions reference 'SPL/RD/UI/202006119', issue no, '01' dated 20.08.2020. Cure for 24 hours@30°C. For use with water up to 50°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'RE971 Natural'. Clear, extruded, single layer TPU hose. For use with water up to 85°C.
'RE971 Red, Blu, White and Grey'. Dual layered, extruded hoses consisting of a clear inner TPU inner layer and red, blue, white or grey coloured TPU outer layer. For use with water up to 85°C.
Dowlex NG2432UE. Dowlex NG2432.10UE. RX 103 Natural. RX 103 Black 9003. RX 103 GR Black 9003. Natural and black coloured, rotationally moulded polyethylene material. For use with water up to 70°C.
‘Tecomid HT NT40 GR30 BK009 01 QW, Tecomid HT NT40 GR35 BK009 01 QW, Tecomid HT NT40 GR40 BK009 01 QW, Tecomid HT NT40 GR45 BK009 01 QW, Tecomid HT NT40 GR50 BK009 01 QW, Tecomid HT NT40 GR55 BK009 01 QW & Tecomid HT NT40 GR60 BK009 01 QW’. Black coloured, injection moulded glass-fibre reinforced PPA materials. For use with water up to 85°C.
'USW-95-A Black'. Black coloured, injection moulded TPU material. For use with water up to 23°C.
‘EPDM-FF’. Black coloured, compression moulded EPDM rubber material. Shore hardness 80A. Tested in-radius size 0.89mm. For use with water up to 85°C.
‘ELASTOSIL® R plus 4303/60 mH (60), ELASTOSIL® R plus 4303/70 mH (70) and ELASTOSIL® R plus 4303/80 mH (80)’. Extruded, natural (appears white in colour) platinum cured HTV silicone rubber with a shore hardness of between 60 & 80. Tested in-radius size 2.0mm. The rubbers may also be coloured using the following ELASTOSIL® Color Pastes PT in a maximum of 1% content: PT Carbon black RAL 9005. PT Red brown RAL 3013. PT Red RAL 3000 F. PT Yellow RAL1016 PT Yellow RAL 1026 F PT Yellow RAL 1021. PT Grey RAL 7040. PT Dark blue 5010. PT Ultramarine blue RAL 5002. PT Violet RAL 4001. PT Green RAL 6017. PT Black RAL 9017. PT White RAL 9010. PT Yellow RAL 1033. PT Orange RAL 2004 F. PT Violet RAL 4002. PT Blue RAL 5022. PT Helio green RAL 6004. For use with water up to 85°C.
Range of single hole, single outlet (fixed) electronically operated tap assemblies incorporating brass bodies (various finishes). Flow is controlled via solenoid valve and actuated by a touch sensor. The hose inlet incorporates a flow restrictor and the spout outlets incorporate a plastic aerator. Maximum working pressure 7.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with a pull-out spray mechanism. Flow is controlled via a ceramic cartridge headwork with a single lever operating member incorporating an infra-red sensor on the swivel arm which operates a solenoid valve. The spout outlet incorporates a plastic aerator and a hand spray mechanism, and the product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Concealed WC dual flushing cistern with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10 bar. Cold water use only.
Range of concealed cisterns incorporating a side entry float operated inlet valve providing a type AC air gap arrangement and a dual flush outlet valve. Maximum working pressure 10.0 Bar. Cold water use only.
BS EN 997:2018 Roca Wall Hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by a manual push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ or Illusion Compact Universal frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Range of thermostatic cartridges incorporating brass bodies, stainless steel strainers and EPDM ‘O’-rings. For insertion into specifically dimensioned tap bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The product incorporates a pull-out spout outlet with a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet can incorporate either a plastic flow straightener or a plastic aerator. When supplied with a plastic flow straightener there is a combined EPDM washer and stainless steel strainer behind it. The products are available either as a version with a pop-up waste or one with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of wall mounted, electronically operated combination tap assemblies (various finishes, see model ) incorporating a solenoid valve controlling the flow which is actuated via in infrared sensor. The spout outlets incorporate a aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Two-hole, single outlet (fixed) combination tap assembly with a brass body (chromium plated), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet is a waterfall design. The inlets incorporate plastic flow restrictors. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Models 91742, 95660 incorporate a non-rising spindle headwork with dome type operating members. Model 21775 incorporate a non-rising spindle headwork with cross top operating members. Model 77174 incorporate a quarter turn ceramic disc headwork with single lever operating members. The fitting incorporates a manual diverter to the shower outlet The spout outlet incorporates a plastic flow straightener and the products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Uponor S-Press (black and grey) composite fittings, Uponor S-Press composite PPSU reducers with S-Press PLUS composite PPSU nipples, Uponor RS fittings & Uponor S Press Metal Press fittings for use with for use with Uponor MLC pipe. Maximum working pressure and operating temperature: 10.0 bar@70°C Maximum working pressure and operating temperature: 16.0 bar @ Cold water use only.
Range of Eco Duo copper press fittings with EPDM ‘O’-rings for use with Eco-Duo copper tube. The joints are achieved by means of a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Aquaflow polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of Kelox Protec brass & PPSU push fit connection fittings with EPDM seal rings for use with Kelox multilayer composite pipe (PE-RT type ll/AL/PE-RT type ll). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of brass compression fittings for use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of polypropylene push-fit fittings and inserts for use with MDPE pipe (manufactured to BS EN 12201). For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of polypropylene push-fit fittings with inserts for use with MDPE Pipe (manufactured to BS EN 12201-2) on one side of the fitting and PB (BS 7291), PEX (BS 7291) or Copper (BS EN 1057) on the other. Models UTS147-DB, UTS197-DB & UTS251-DB are for above and below ground use. All other models are for above ground use only. Maximum working pressure when using 20mm pipe is 16.0 bar. Maximum working pressure when using 25mm & 32mm pipe is 12.5 bar. Cold water use only.
Range of capillary end feed bronze fittings for use with copper tube (manufactured to BS EN 1057). 15mm – 54mm fittings have a maximum working pressure of 25.0 bar. 67mm – 108mm fittings have a maximum working pressure of 16.0 bar. Maximum operating temperature 100°C.
Range of single flush siphonic WC outlet valves comprising of a plastic body, LDPE diaphragm washer and stainless steel C link. Cold water use only.
Dual flush, WC outlet valve operated via a push button assembly for either full or reduced flush. Cold water use only
Dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.
Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.
Water meter incorporating a brass inner body, a plastic outer body and liquid silicone ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of concealed bathroom boxes with extractable shower hoses. The inlet attached to the concealed box incorporates an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the shower hose also includes a stainless steel strainer. Maximum operating temperature 60°C.
Page 9 of 82
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.