Two hole, single outlet (fixed) combination tap assembly (chromium plated brass & matt black finishes) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of wall mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks with single lever, dome or cross top operating members and manual diverters to shower outlets. This approval includes a hose, handset and wall bracket and the products are supplied with plastic backnuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of deck Mounted bar type thermostatic combination tap assemblies (chromium plated brass), incorporating a ½ turn ceramic disc headwork controlling the flow with either dome type (AR2 THBSM C & BWY AR2 THBSM C) or single lever (AR2 THLBSM C) operating members. The temperature is controlled independently via a thermostatic cartridge with either dome type (AR2 THBSM C & BWY AR2 THBSM C) or single lever (AR2 THLBSM C) operating members incorporating a manual override button. The product also incorporates a manual diverter between the spout outlet and shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a stainless steel strainer and a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted two-hole, single outlet (fixed) bath shower mixers with brass bodies (various finishes), incorporating a manual diverter controlling and diverting the flow between the spout outlet and an overhead shower. Temperature is controlled independently via a thermostatic cartridge with dome type operating member with manual override button. The spout outlets incorporate a plastic aerator. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the product is supplied with a shower hose, shower handset and metal backnuts Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with dome type operating members, the temperature is controlled independently via a thermostatic cartridge with single lever operating members with a manual override button and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. Inlets incorporate stainless steel strainers approved check valve cartridges, (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with single lever operating member and self-cancelling diverter to shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, singleoutlet (swivel) combination tap assemblies (chromium plated brass). Incorporating non rising spindle headworks with various operating members. The spout outlets incorporate a plastic flow straightener. Products are supplied with plastic backnuts, model DCM SPEC105 is supplied with metal backnuts Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet, swivel combination tap assembly (chromium plated brass) incorporating ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60 °C.
Two hole, double outlet (swivel) combination tap assembly (chromium plated brass) incorporating non-rising spindle headworks with dome type operating members. Product is supplied with metal back nuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
ALT Series of wall mounted anti-ligature outlets with a touch operated solenoid valve incorporating a flow regulator which controls the flow. The outlets arrangement can be either a single inlet/outlet (ALT-81) or two independent inlets and outlets (ALT-80) both controlled via a solenoid valve. To be installed within a suitable basin (not supplied as part fo the this approval) Internal connecting pipework can be either threaded or push fit depending on model variant. Can be fitted with either an approved aerator or flow straightener. Maximum working pressure 10 bar. Maximum operating temperature 60°C
WHB & ALS series of wall mounted anti-ligature wash hand basins with outlets. Incorporating a basin with a piezo activated button or infrared activation which controls the flow via a solenoid valve to either an independant single or double inlet made from chromium plated brass and incorporating a flow straightener or aerator. Internal connecting pipework can be either threaded or push fit depending on model variant. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of concealed wall mounted bath shower mixers (brass body) incorporating a manual diverter to bath or shower handset. Flow is controlled by cartridge headworks using single lever type or dome operating members. Temperature is independently controlled via a single lever or dome type operating member incorporating a manual override button. Manual diverter is also controlled by single lever or dome operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of standpipes for bath/showers with a brass body (various finishes, see model). The standpipes incorporate an approved flexible hose. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Bath spout with a brass body (chromium plated). The spout outlet incorporates a plastic aerator. Maximum operating temperature 60°C.
Range of spout outlets incorporating brass bodies and NBR ‘O’-rings. The spout outlets incorporate a plastic flow straightener. Models AX-SIR-140/RO/DIV and AX-BOK-140/SQ/DIV incorporate a self-cancelling diverter. Maximum operating temperature 60°C.
`Wellmate` range of expansion vessels with plastic bodies and rubber diaphragms Maximum working pressure 8.6 Bar, cold water use only.
‘Copper press fittings - M Profile’ range of press fittings with a brass body and EPDM ‘O’-rings for use with copper pipe manufactured to EN1057:2006 +A1:2010 seamless round copper tube R250. Joints are achieved using a specialist press fitting tool. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
“Plimat PVC-U Fittings BS Inch and PVC-U Fittings Threaded” range of PVC-U solvent cement or threaded fittings for use with “Plimat PVC-U BS inch pipe” (manufactured to EN1452-2). Maximum working pressure 15.0 bar for solvent cement connections and 10.0 bar for fittings that only include/also include a threaded connection. Cold water use only.
'ALTOPOLY PB pipe'. Grey coloured, extruded multi-layered pipe consisting of a polybutylene inner and outer layer and a dark grey coloured EVOH middle barrier layer and 'ALTOPOLY EVOH PEX Pipe'. Extruded, multi-layered pipe consisting of a white coloured PEX inner, blue coloured EVOH middle layer and white coloured PEX outer. For use with SNC Corporation ‘Twistloc’ push-fit fittings covered by WRAS approval 1904906. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Uponor S-Press press fittings, Uni-X & Uni-C compression fittings for use with Uponor MLC pipe. Maximum working pressure 10.0 bar, maximum operating temperature 70°C.
‘CB ISR’ range of capillary fittings with internal solder rings, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of copper and bronze capillary brazed fittings for use with copper pipe manufactured to EN1057:2006 +A1:2010. Maximum pressure 10.0 Bar (54mm up to and including 108mm) Maximum pressure 2.0 Bar (Over 108mm up to and including 159mm) Maximum operating temperature 100°C.
Range of compression fittings with polypropylene bodies, nuts, acetal grip rings, EPDM ‘O’-rings and plastic pipe liners for use with MDPE pipe manufactured to BS EN 12201. For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
‘EPH_WSP19’ Range of brass bodied fittings for use with copper pipe, some fittings are to be soldered with copper pipe (see models). Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
“Plimat ABS Fittings BS Inch and ABS Adaptor Fittings” range of ABS solvent cement or threaded fittings for use with “Plimat ABS pipe”. Maximum working pressure: 15.0 bar (fittings with ½” - 4” solvent cement connections), 9.0 bar (fittings with 5” or 6” solvent cement connections, with or without threaded connecitons), and 10.0 bar (fittings with threaded connections and ½” - 4” solvent cement connections). Cold water and above ground use only.
Range of PSU, POM & DZR brass pushfit fittings for use with PE-x pipe (manufactured to BS7291-3), PB pipe (manufactured to BS7291-2) & copper pipe. Maximum working pressure 10.0 bar @ 65°C (PSU & DZR Brass Fittings). Open outlet use only @ 20°C (POM Fittings).
Range of floor standing commercial glass washers incorporating a solenoid valve controlling the flow. The product is supplied with a double check valve assembly (suitable for backflow protection against fluid category 3). Maximum working pressure 4.0 Bar. Maximum operating temperature 60°C.
Range of stainless steel plate heat exchangers. The product incorporates a stub pipe with a ½” BSP (F) end connection on the secondary flow (outlet) which can accommodate a control sensor and strap on limit thermostat, (neither of which are supplied or considered part of the approval listing). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Range of indirect heat interface units providing heating and instantaneous hot water. The hot water and space heating is provided via two separate plate heat exchangers. The space heating circuit incorporates an expansion vessel and expansion relief valve (set @ 3.0 bar). The primary circuit only is supplied with isolation valves on the flow and return. Maximum working pressure primary 16.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water (DHW) 10.0 bar. Maximum operating temperature primary 75°C. Maximum operating temperature space heating 85°C. Maximum operating temperature secondary hot water (DHW) 65°C.
Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
Range of copper brazed stainless-steel heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Range of stainless steel, copper brazed plate type heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Range of water meters with plastic bodies and EPDM ‘O’-rings. The inlets incorporate a plastic strainer. Maximum working pressure 10.0 bar. Cold water use only.
Range of shower hoses and riser rail with chromium plated brass bodies, incorporating EPDM ‘O’-rings. Maximum operating temperature 85°C.
Shower hose and handset with sliding rail and inlet kit. The inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of plastic manifold systems designed to accept interchanagble sensors (not supplied). Maximum working pressure 6.0 bar. Cold water use only.
Immersion temperature sensors with DZR bodies and an EPDM ‘O’-ring (STDW14 model only). Maximum working pressure 15.0 bar. Maximum operating temperature 100°C.
Range of shock arrestors with carbon steel or stainless steel bodies (available in various external surface finishes) incorporating Bromobutyl (BIIR) membranes. Maximum working pressure 10.0 bar. Cold water use only.
Range of shock arrestors with stainless steel bodies incorporating Bromobutyl (BIIR) membranes. Maximum working pressure 10.0 bar. Cold water use only.
Air break to drain, incorporating brass bodies with a grey epoxy powder coating. Maximum operating temperature 60°C.
Impeller with plastic body for insertion into specifically dimensioned bores. Maximum operating temperature 70°C.
Wall mounted chrome plated brass elbow fitting. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Shower kit comprising of shower handset (chrome plated brass body), shower hose, 90° wall elbow, stainless-steel braided supply hose & faceplate with single lever operating members. The inlet to the shower handset incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Shower kit consisting of a shower handset (chrome plated plastic), riser rail and PVC lined multi-layered shower hose with brass connections, EPDM 'O'-rings and washers. Maximum operating temperature 60°C.
Range of shower handsets incorporating ABS bodies (chrome plated), EPDM seals and ‘O’-rings. Maximum operating temperature 65°C.
Wall mounted vandal resistant shower head with (chrome plated brass finish). The inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet incorporates a plastic aerator. Open outlet use only. Maximum operating temperature 60°C.
A range of shower handsets with chromium plated plastic bodies and a plastic strainer and flow regulator in the inlet. Models may incorporate dark grey alternative shower plate. Maximum operating temperature 85°C.
Page 9 of 224
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.