'ML 57314'. Black coloured, compression moulded EPDM material. Shore hardness 68A. Tested in-radius size 1.0mm. For use with water up to 23°C.
Single hole, triple outlet (swivel) combination tap assembly (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with single lever operating member. Electronic controls allow the tap to dispense boiling, chilled or sparkling water. The vented models are supplied with a brass adaptor containing a plastic flow regulator and a combined EPDM washer and stainless-steel strainer, for installation on the mains cold water into the ceramic cartridge. They are also supplied with a stainless steel braided PEX lined flexible hose assembly and a stainless steel braided TPSiV lined flexible hose assembly both with ½” captive nut end connections for installation between the tap and a command centre, (which is not included as part of this approval). Maximum working pressure 5.0 bar. Maximum operating temperatures: Near boiling water circuit: 100°C. Ambient hot and cold (mixed) circuit: 65°C. Chilled/Chilled and sparkling circuit: Cold water use only.
Electronically operated combination tap assembly, (chrome plated brass body). The flow is controlled by a solenoid valve which is actuated via an infrared sensor on the spout. The spout outlet incorporates a plastic aerator. The product is supplied with a stainless steel braided (EPDM or PEX lined) flexible connecting hose. Maximum working pressure 8.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Three-hole, single outlet (fixed), combination tap assembly (brass body – various finishes), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to the shower outlet. The product is supplied with a stainless-steel braided EPDM lined flexible connection hose to connect the head work to the spout outlet. Maximum working pressure 5.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Spring loaded resilient trim check valve cartridge with stainless steel spring and EPDM `O`-ring. For insertion into specifically dimensioned bores. Maximum working pressure 16 Bar. BS6920 at 85°C
Range of aerator kits incorporating plastic flow regulators (1.9l/min, 3.5l/min & 5.0l/min) with plastic bodies and EPDM ‘O’ rings. Plastic adaptors, NBR washers and chromium plated brass housings may also be supplied as part of the kit. Maximum operating temperature 65°C.
Range of push button ceramic cartridge headworks with a plastic body and EPDM seals. For insertion into specifically dimensioned tap assemblies Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Non-metallic materials and components comply with BS6920 at 65°C
Thermostatic cartridge with plastic body incorporating EPDM ‘O’-rings and stainless steel strainer. To be installed into specifically dimensioned bores. Maximum working pressure 10 bar. Maximum operating temperature 85°C
Thermostatic cartridges with plastic or brass bodies, and EPDM ‘O’ rings and stainless steel strainers. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. BS6920 85°C.
‘VT30’ range of thermostatic cartridges with a plastic body and EPDM ‘O’-rings and stainless steel strainers. For insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. BS6920 70°C.
Range of single hole, single outlet, swivel combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The vented models are supplied with a stainless steel braided PEX lined flexible hose assembly incorporating a ½" captive nut end connection, which provides main cold water to a venturi device which is part of a command centre (not supplied). The Arc vented models are supplied with a DZR brass tee piece, two DZR brass adaptors, two stainless-steel strainers (each combined with an EPDM washer) and a plastic flow restrictor, for installation prior to the cold inlet hose. The Arc and Cube mains models are supplied with two DZR brass adaptors and two stainless-steel strainers (each combined with an EPDM washer), for installation on each inlet hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Sensor control boxes, flow is controlled using a solenoid valve assembly. Flow is activated via infra-red sensor and product incorporates a stainless steel filter and EPDM ‘O’-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 75°C.
Spout outlet consisting of a chromium plated brass body, plastic aerator and EPDM ‘O’ rings. Maximum operating temperature 60°C.
Range of wall-mounted spout outlet consisting of a brass body with various finishes, plastic aerator and EPDM ‘O’ rings. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of expansion vessels with epoxy coated steel bodies and EPDM diaphragms. Maximum working pressure 8.0 or 10.0 bar (please refer to model). Maximum operating temperature 70°C or 100°C (please refer to model).
Range of shock arrestors with stainless steel bodies and EPDM diaphragm. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Range of expansion vessels with epoxy coated steel bodies and EPDM diaphragms. Maximum working pressure 8.0 or 10.0 bar (please refer to model). Maximum operating temperature 70°C or 100°C (please refer to model).
Range of expansion vessels with epoxy coated steel bodies and EPDM diaphragms. Maximum working pressure 8.0 or 10.0 bar (please refer to model). Maximum operating temperature 70°C or 100°C (please refer to model).
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Models ALT-ST0019 & ALT-ST0019 are supplied with a pressure gauge. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of filling loop assemblies consisting of an in-line isolation valve, an in-line double check valve assembly (suitable for back flow protection against fluid category 3) that incorporates an isolation valve and a stainless-steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Filling loop assembly comprising of a spherical valve, stainless-steel braided EPDM lined flexible hose and a double check valve assembly ((suitable for backflow protection against fluid category 3) which incorporates a lever operated spherical valve. Maximum working pressure 10.0 bar. Cold water use only.
Filling loop assemblies comprising of a stainless steel braided, EPDM lined hose, double check valve assembly with isolation valve verified by test (suitable for backflow protection against fluid category 3) and either a straight or tee isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
‘Blutron’ plastic bodied filter head incorporating EPDM ‘O’-rings for use with filter cartridges (not supplied).For use with LLDPE tube (manufactured to DIN 8072). All models can be specified with or without an integral bracket. Maximum working pressure 6.0 bar. Cold water use only.
SD 200` pressure augmenting fire sprinkler device comprising of an end suction fire pump with a non-return valve on its outlet, multistage jockey pump with a lever operated spherical valve and non-return valve on its outlet, galvanised steel and copper pipework, pressure switches and gauges, pump sensing unit and two stainless steel braided EPDM lined hoses. Maximum working pressure 11.0 bar. Cold water use only.
Range of stainless-steel press fittings with EPDM ‘O’-rings and EPDM washer (Live joint with BSP female thread models only) for use with stainless-steel pipe. Joints are achieved using a press fitting tool. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
‘F18’ range of brass press fittings (TH and U crimp profiles) with EPDM ‘O’-rings for use with Rifeng B1 PEX/AL/PEX multilayer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of brass press fittings (TH and U crimp profiles) with EPDM ‘O’-rings for use with RIIFO B1 PEX/AL/PEX multilayer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
U Profile range of press fittings incorporating EPDM ‘O’-rings. For use with Mingshi (S-1-0509/10/11/12/17/13) PEX-AL-PEX pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C
Range of ‘Henco Profit Synthetic’ pushfit fittings with PPS (HPK models) or brass (HP models) bodies and EPDM o-rings, to be used with ‘Henco RIXc’ PEXc/Al/PEXc multilayer pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of MM and MC press fit fittings with PPSU bodies incorporating stainless steel crimp sleeves and EPDM O-Rings for use with AIS XPERT multi-layer pipes. Maximum working pressure is 10.0 bar. Maximum operating temperature is 70°C.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Stainless steel press fittings incorporating EPDM ‘O’-rings for above ground use only. To be used with stainless steel 316L pipe (EN 10312). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
AMEX-10 Vario internal pipe repair kit incorporating stainless steel retaining rings and EPDM seal. Maximum operating temperature 23°C.
Non-metallic materials and components comply with BS6920 at 23°C
Range of water meters with brass bodies, plastic transducers, and EPDM O-rings. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
‘JS’ range of water meters with brass bodies and EPDM ‘O’-rings and plastic strainer on inlet. Maximum working pressure 16 bar. Cold water use only.
Range of ultrasonic water meters with brass bodies and EPDM O-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Water meter with a plastic body and working chamber incorporating and EPDM ‘O’-ring, NBR ‘O’-ring and seal. Maximum working pressure 16.0 bar. Cold Water use only.
Range of water meters with brass bodies, with integral plastic strainer and EPDM ‘O’- rings. The product is supplied with an optional combined plastic washer and stainless-steel strainer for installation on the inlet. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meters with plastic or brass bodies, incorporating EPDM O-rings. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 50°C
Range of water meters with DZR brass bodies and EPDM ‘O’-rings. The inlet incorporates either a plastic or stainless steel strainer (see model). The product is supplied loose fibre gaskets for installation on the inlet and outlet. Maximum working pressure 16.0 bar. Cold water use only.
Range of ultrasonic water meters with plastic bodies and transdcuers, and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. BS6920 50°C.
Range of water meters with blue epoxy coated ductile iron body, incorporating an EPDM diaphragm, NBR ‘O’ rings, stainless steel strainer and a polypropylene rotor. The products incorporate a second bypass meter assembly and a check valve cartridge (however, the complete product has not been fully tested for and is not intended to provide backflow protection). Maximum working pressure 16.0 Bar. Cold water use only.
Range of ultrasonic water meters with blue epoxy coated cast iron bodies, EPDM ‘O’-rings and plastic flow straighteners. Maximum working pressure 16.0 bar (DN50 to 200) or 10.0 bar (DN200 only)
Non-metallic materials and components comply with BS6920 at 50°C
Magnetic non-return valve with a brass body and EPDM seals. Maximum working pressure 16.0 Bar. Cold water use only.
Range of hose assemblies. Models B0301-148036-000 & B0301-148038-000 comprise of a spherical valve, stainless-steel braided EPDM lined flexible hose and double check valve assembly (suitable for backflow protection against fluid category 3). Model B0301-148037-000 comprises of a double check valve assembly (suitable for backflow protection against fluid category 3), stainless-steel braided EPDM lined flexible hose and ‘T’ type spherical valve. Maximum working pressure 10.0 bar. Cold water use only.
Hydraulic circuit used to control the water path within the heating and sanitary boiler, with plastic body incorporating filter, flow regulator, plate heat exchanger and EPDM O-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 85°C.
Three hole, basic rough-in set with a brass body, incorporating EPDM O-ring seals. The product is supplied with a shower hose and a stainless steel braided, silicone lined flexible connecting hose. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 70°C
Range of vertical multistage pumps with cast iron bodies with a black electrodeposition coating, stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: MVX 30 & MVX 45- 32.0 bar, MVX 65 & MVX95 VR - 25.0 bar. Cold water use only.
Range of circulating pumps with a bronze body, plastic impeller and EPDM gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Page 27 of 44
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.