Range of shower handsets and overhead showers with metal chromium plated bodies with. Models 20123 and 15185 are fitted with check valves at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Model 20127 is supplied with a flexable hose connection. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of shower arms and brackets with brass bodies (various finishes). Shower brackets incorporate single check valves cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum operating temperature 85°C.
Range of overhead shower outlets incorporating brass bodies (chrome plated) and EPDM gaskets. Inlets have stainless filters incorporated within a ball joint. Maximum operating temperature 85°C
Range of overhead shower outlets (chrome plated plastic bodies). Inlets incorporate a strainer. Maximum operating temperature 85°C
Range of flow switches with brass bodies incorporating EPDM ‘O’-rings, acting as a leak detection system that actuates an integral spherical valve to shut off the water supply. The inlet incorporates a stainless steel strainer. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 30°C.
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps incorporating brass bodies (chrome plated), non-rising spindle headworks (models 922031 & 922033) or quarter turn ceramic disc headowks (all other models). The spout outlet incorporates a flow straightner. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of pillar taps incorporating brass bodies (chrome plated), non-rising spindle headworks (model 922038) or quarter turn ceramic disc headowks (model 922068). The spout outlet incorporates an flow straightener Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Self-closing basin tap assembly (chromium plated brass) incorporating spring loaded headwork and dome type operating members. The inlet incorporates a plastic flow restrictor and the spout outlet incorporates a plastic flow straightener. The product is supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 70ºC.
Range of stainless steel braided, EPDM lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of EPDM braided hoses (various options) and optional end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies, incorporating EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Advance Appliance ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.
Range of “Tempest” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.
Whitewolf Alpha ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Elite ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Flowcyl ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Nucyl ranges of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
502 series of automatic air venting valves with brass bodies, plastic float and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 115°C. Model added September 2021 (501500) has a maximum operating temperature of 120°C. All other models have a maximum operating temperature of 115°C.
Page 24 of 205
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.