Range of Easytec press fittings for use with Easytec multilayer (Pe-rt/Al/Pe-rt) pipe. Hewing range of ‘Easytec’ Multilyer Composite Pipe and Press Fitting system with brass press fittings with stainless steel sleeves incorporating EPDM o-rings. 16mm to 32 mm are LBP fittings and from 40mm to 63 mm are standard fittings. Joints are achieved via TH profile press tool. Maximum working pressure: 10bar Maximum working temperature: 95°c
Range of brass bodied compression fittings for use with copper pipe(manufactured to EN1057). . Maximum working pressure 16.0 bar @ 30°C, 10.0 bar @ 65°C and 6.0 bar @ 100°C.
Range of ultrasonic water meters with plastic bodies. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
‘DM900’ range of flow measuring devices with stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.
Range of temperature measurement devices with bronze bodies and EPDM o-rings. Maximum operating pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Permanent filling devices for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. If the mains pressure is adequate and there is a drop in system pressure, then the two solenoid valves operate to allow water into the system via the transfer chamber. At all other times the normally open solenoid valve drains the transfer chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Stainless steel strainer on the inlet supply. Mikrofill 3: Maximum working pressure 5.0 Bar. Cold water use only. Mikrofill 3 Pro (72846): Maximum working pressure 9.0 Bar. Cold water use only.
Range of circulator pumps with stainless steel bodies and a plastic impeller. All models are available with a plastic (composite) rotor can, the MAGNA1 range is also available with a stainless-steel rotor can in the DN32 flanged, threaded 1½ & 2” sizes only. The MAGMA3 models have a differential pressure sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Permanent magnet variable frequency multistage pump with plastic bodies, plastic impellers, stainless steel shaft and EPDM ‘O’-rings. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Wall mounted shower outlet (brass body – various finishes). The product is supplied with shower hose and handset that incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower heads with chromium plated ABS bodies. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 75°C
Range of overhead showers consisting of stainless steel bodies and silicone nozzles and gaskets and shower handsets consisting of ABS (LB-2003N, LB-2003, LB-2004) or brass bodies (LB-2006 & LB-2028).
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets & overhead shower outlets with chromium plated plastic body. The inlets of the overhead shower outlets incorporate a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with (brass bodies – various finishes), incorporating EPDM `O`-rings and a plastic strainer. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Range of hand showers with (plastic bodies - various finishes). The products incorporate a stainless-steel strainer and flow regulator. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of draining taps with DZR brass, brass or chrome plated brass bodies. Incorporating a rising spindle headwork, EPDM or NBR seals and washers. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of draining taps with DZR brass, brass or chrome plated brass bodies. Incorporating a rising spindle headwork, EPDM or NBR seals and washers. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The CMBHUBDC-D model incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.
Range of pillar tap (chrome plated brass), incorporating quarter ceramic disc headworks with single lever or dome type operating members. The spout outlets incorporate plastic aerators. Products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Page 213 of 590
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.