Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C
Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Gas fired water heaters incorporating a heat exchanger and flow sensor. The inlet incorporates a plastic strainer. The products are supplied with isolation valves for installation on the cold inlet and hot outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60˚C
Range of gas fired condensing water heaters incorporating stainless steel storage tank, buffer tank and strainer on the cold water inlet. Maximum working pressure 10.0 Bar, maximum working temperature 83˚C.
Range of gas fired water heaters incorporating stainless steel strainers on the inlets. Maximum working pressure 10.0 Bar Maximum working temperature 85˚C
LCB700 range of internal and external oil-fired condensing combination boilers providing domestic hot water and pressurised central heating via a plate heat exchanger. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). Operating parameters: Primary (space heating) circuit: Maximum working pressure 2.5 Bar. Maximum operating temperature 105°C. Secondary (DHW) circuit: Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of heat interface units (HIU) with either twin or single stainless steel copper brazed plate heat exchangers (depending on model) providing heating and hot water (twin unit) hot water only, or heating only. The hot water is generated via a plate heat exchanger. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product incorporates a CAb backflow prevention device (suitable for backflow protection against Fluid Category 3) for filling the heating circuit. The inlet and outlet of all circuits incorporate a lever operated spherical valve. Maximum working pressures and operating temperatures: Primary (district heating): 10.0 bar and 85˚C. Domestic hot water (DHW): 10.0 bar and 60˚C. Secondary (space heating): 2.5 bar and 80˚C.
Range of ice making machines which incorporate a solenoid valve to control the flow. Maximum working pressure 5.0 bar. Cold water use only.
Range of commercial ice making machines which incorporate a solenoid valve controlling the flow. Maximum working pressure 7.8 bar. Cold water use only.
Wallgate CWC Series 250 WC pan with direct acting flush valve and DFKIT03 air break (DC device). WC flushing mechanism has a solenoid valve controlling the flow, the valves are operated via an infrared sensor or a piezo control button, this mechanism is fitted with a DC pipe interrupter, the DFKIT03 is fitted with a flow regulator. Maximum working pressure 2.0 bar. Cold water use only.
Vola 200M separate outlet socket with brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pumps with either brass or stainless-steel bodies, stainless steel impellor and NBR ‘O’ rings. 20 & 33 brass series have a maximum working pressure of 16.0 bar. 33 stainless-steel series has a maximum working pressure of 20.0 bar. 22, 24 ,26, 38, 31, 32 & 34 series have a maximum working pressure of 20.0 bar. Cold water use only.
Range of circulating pumps, with plastic or stainless steel bodies (cast EN 1.4308 or plate EN 1.4301) and a plastic impeller. Maximum working pressure 10.0 bar (stainless steel bodied pumps), 3.0 bar (plastic bodied pumps). Maximum operating temperature 95°C.
Range of single stage circulating pumps with plastic impellers and stainless steel housing, (red external coating - all models, and from July 2023 a yellow external coating on the 1½" model with 130mm port length). From December 2023 the UPS25 prefix models can be supplied with EPDM inlet/outlet gaskets and the UPS32 prefix models can be supplied with fibre/NBR inlet/outlet gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C (s/steel plate EN 1.4301/1.4401 models) or 99°C (s/steel cast EN 1.4308 models).
Shower outlets, with NBR and EPDM ‘O’-rings and silicone nozzles. The shower handset has a plastic body with a chrome plated brass outer body and the overhead shower outlet and shower arm have chrome plated brass bodies The inlet of the shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower consists of socket and ball joint. The inlets of both products incorporates a combined NBR gasket and stainless steel strainer. Maximum operating temperature 60°C.
Shower kit comprising of a stainless-steel, interlocked shower hose, chrome plated, plastic shower handset and riser rail. Maximum operating temperature 85°C.
Range of wall mounted handshower, hose and elbow sets with metal bodies (various finishes), incorporating an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Handsets incorporate an approved check valve cartridge , however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Range of in-line “Y” patterned strainers with brass bodies incoroporating NBR ‘O’-rings and stainless steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of inline strainers incorporating DZR brass bodies and a stainless steel mesh. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Page 22 of 395
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.