WC dual flush drop valve comprising of a plastic body and silicone seating washer. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water only.
Range of commercial glass washing machines with flow controlled via a solenoid valve. The products are supplied with a dual layer supply hose (Grey PVC outer/Black PVC inner) with ¾” captive nuts at either end and a loose double check valve assembly (suitable for backflow protection against Fluid Category 3) for installation prior to the inlet hose. Maximum working pressure 4.0 Bar. Cold water use only.
Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of ‘HYCO’ electric instantaneous water heaters with plastic bodies, NBR and silicone ‘O’-rings. The inlet of model IN96T incorporates a plastic strainer. Maximum working pressure 7.5 bar. Maximum operating temperature 60°C.
‘Hydraulic Block 2’ range of integrated water circuits for use with combination boilers comprising of a plastic body, stainless steel thermistors and a plate heat exchanger. The primary circuit incorporates a pump assembly. Maximum working pressures: Primary Circuit 2.5 bar. Secondary Circuit 10.0 bar. Maximum operating temperatures: Primary circuit 85˚C. Secondary circuit 65°C. Cold supply only.
Hydroblock unit consisting of a stainless steel heat exchanger, a pressure relief valve pre-set at 3.0 bar, diverter valve and return valve. Maximum working pressure 2.5 bar. Maximum operating temperature 90°C
Digital water meter with brass body incorporating a plastic strainer on the inlet and a non-return valve (not suitable for backflow protection) on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Water meter incorporating a brass inner body, a plastic outer body and liquid silicone ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Air break to drain, incorporating brass bodies with a grey epoxy powder coating. Maximum operating temperature 60°C.
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of flow through valves with brass bodies and EPDM ‘O’-rings, incorporating a spherical valve and a separate drain tap. The products are intended for connection prior to an expansion vessel. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of concealed bathroom boxes with extractable shower hoses. The inlet attached to the concealed box incorporates an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the shower hose also includes a stainless steel strainer. Maximum operating temperature 60°C.
VDROO range of stainless steel multistage centrifugal pumps with stainless steel impellers, diffusers and outer sleeves. The pumps incorporate a Silicone Carbide and EPDM mechanical seal. Maximum working pressure 25.0 bar DIN flange. Maximum working pressure 16.0 bar for oval flange. Cold water use only.
Range of cold water supply booster sets, incorporating a stainless steel manifold system and between 1 and 4 pumps depending on model. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels. Maximum working pressure 10.0 bar or 16.0 bar, dictated by the pump model(s) fitted. Cold water use only.
CM(E)(C) range of electronically operated pumps available in stainless steel, (‘EN 1.4301/AISI304’ or ‘EN 1.4401 /AISI316’) and cast iron. (CMEC models were added October 2023). The pumps are supplied with Sic-Sic mechanical shaft seals and FKM or EPDM seals. Cast iron models: Maximum working pressure 10.0 bar. Cold water use only. Stainless steel models: Maximum working pressure 16.0 bar. Maximum operating temperature 60°C for self-priming models, 99°C for all other models.
Dutypoint ‘VS’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels.. Maximum working pressure 10.0 bar. Cold water use only.
Range of black plastic bodied multistage, self or manually primed, high pressure centrifugal pumps with a stainless steel outer casing, plastic impellors, EPDM seals and ‘O’-rings. Maximum working pressure 8.0 bar. Cold water use only.
Page 3 of 48
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.