Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headworks with dome type or single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, four hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks and either single lever (AE89TF) or cross top (AE88TF) operating members. The product includes a self-cancelling diverter to shower outlet, metal backnuts and an approved handshower. The product also incorporates an approved check valve on the shower outlet inlet, and a flow regulating approved check valve on the handshower, however, neither complete products have been fully tested to demonstrate backflow protection. Maximum working pressure: 3.5 bar. Maximum operating temperature 60ºC.
Range of floor mounted, single outlet, combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and self-cancelling diverter to shower outlet. The spout outlets incorporate plastic aerators. The product is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted spout outlets (chromium plated brass) incorporating a plastic flow regulator at the inlet. Model 13800670 incorporates a plastic aerator at the outlet. Maximum operating temperature 60°C.
Floor standing spout outlet (chromium plated brass) and concealed body (cast brass body) Maximum operating temperature 60°C.
Range of spout outlets with brass bodies (various finishes), EPDM ‘O’-rings and a plastic aerator. Maximum operating temperature 60°C.
Range of expansion vessels with stainless steel bodies and rubber diaphragms. Maximum working pressure 10.0 bar. Cold water use only.
Filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve (suitable for back flow protection against fluid category 3) and a stainless steel braided EPDM lined hose. The isolation valves are operated via a single lever. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of water filters comprising of plastic filter cartridges with carbon blocks and plastic filter heads for use with 'John Guest LLDPE' pipe. Maximum working pressure 8.6 bar. Cold water use only.
Range of water filters comprising of polypropylene housings and caps. The filter head incorporates an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 7.0 bar. Cold water use only.
Range of brass press fittings with EPDM ‘O’-rings for use with Rifeng B1 PEX/AL/PEX multilayer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of brass press fittings with EPDM ‘O’-rings for use with EBRILLE multilayer pipe. Maximum working pressure 10 bar. Maximum operating temperature 95°C.
‘ISR’ range of copper, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of brass compression fittings for use with copper pipe. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press-fit fittings with brass bodies and EPDM `O`-rings for use with copper pipe manufactured in accordance with EN1057. Maximum working pressure 16.0 bar (sizes 12mm to 34mm). Maximum working pressure 10.0 bar (sizes 35mm to 54mm). Maximum operating temperature 90°C.
Range of WC dual flush drop valves with an ABS body and silicon seal. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal adjustable height overflow. Cold water use only.
Range of commercial glass washing machines with flow controlled via a solenoid valve. The products are supplied with a dual layer supply hose (Grey PVC outer/Black PVC inner) with ¾” captive nuts at either end and a loose double check valve assembly (suitable for backflow protection against Fluid Category 3) for installation prior to the inlet hose. Maximum working pressure 4.0 Bar. Cold water use only.
Copper plate heat exchanger with copper connections, incorporating 72 fins. Maximum working pressure Heating circuit 3.0 bar, Sanitary circuit 8.0 bar Maximum operating temperature 99°C
An in-line ultra-sonic water meter with brass or plastic bodies (see model). Maximum working pressure 16.0 bar. Maximum operating temperature 70°C.
Range of water meters with black nylon bodies and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Cold water use only.
Page 3 of 554
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.