Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chromium plated), incorporating ceramic cartridge headworks and single lever operating member. The connection to flexible hose and spray outlets incorporates an approved single check valve cartridge (however, the whole product has not been fully tested to demonstrate that it provides adequate backflow protection) the outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes) incorporating a ¼ turn ceramic disc headwork supplied with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies incorporating a brass body (chrome, nickel or black finish) and ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies (chromium plated or white painted brass), incorporating quarter turn ceramic disc headworks and single lever type operating members. Outlets incorporates a plastic flow straightener. Maximum operating pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes) incorporating a quarter turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operaring temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted two-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes) and ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, metal, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc cartridge headwork with single lever operating members. The outlets incorporate a plastic aerator and the products are supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Two hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes), ceramic cartridge headworks and single lever operating members. The spout outlets incorporates a plastic aerator. Fittings are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever type operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic aerator and the product is also supplied with a shower handset and hose. The inlet of the shower handset incorporates a plastic flow regulator. The product is supplied with either plastic or metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. The inlet offset unions incorporate a servicing valve and the inlets to the taps incorporate a plastic flow restrictor. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, metal, single outlet (fixed) combination tap assemblies available with various finishes (see models). Incorporating quarter turn ceramic disc headwork with various operating members (see models). The spout outlet incorporates a plastic aerator. Products are supplied with metal backnuts & lever type pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headworks with dome type or single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headwork WITH single lever operating members. The spout outlets incorporate a plastic aerator. The headwork is connected to the spout via stainless steel braided, EPDM lined flexible hoses. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The headwork is connected to the spout via stainless steel braided, EPDM lined flexible hoses. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Three-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener or optional plastic aerator. The product is supplied with metal backnuts, lever operated pop-up waste and stainless steel braided PEX lined flexible hose assemblies intended for connection between the valves and spout. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Page 3 of 560
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.