‘ISR’ range of copper, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
‘CB ISR’ range of capillary fittings with internal solder rings, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of compression fittings with polypropylene bodies, nuts, acetal grip rings, EPDM ‘O’-rings and plastic pipe liners for use with MDPE pipe manufactured to BS EN 12201. For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Fluidfit range of hose barb fittings/stem fittings with push fit connections. Also with EPDM ‘O’-rings. 12 & 15mm models are for use with LLDPE pipe, 22mm models are for use with PEX pipe. Cold water use only Maximum working pressure 10.0 Bar
“Plimat ABS Fittings BS Inch and ABS Adaptor Fittings” range of ABS solvent cement or threaded fittings for use with “Plimat ABS pipe”. Maximum working pressure: 15.0 bar (fittings with ½” - 4” solvent cement connections), 9.0 bar (fittings with 5” or 6” solvent cement connections, with or without threaded connecitons), and 10.0 bar (fittings with threaded connections and ½” - 4” solvent cement connections). Cold water and above ground use only.
Range of dual flush WC syphons incorporating a polypropylene body, stainless steel C link and a LDPE sealing washer. The valve is to be operated via a handle lever. Cold water use only.
Range of stainless steel plate heat exchangers. The product incorporates a stub pipe with a ½” BSP (F) end connection on the secondary flow (outlet) which can accommodate a control sensor and strap on limit thermostat, (neither of which are supplied or considered part of the approval listing). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Range of indirect heat interface units providing heating and instantaneous hot water. The hot water and space heating is provided via two separate plate heat exchangers. The space heating circuit incorporates an expansion vessel and expansion relief valve (set @ 3.0 bar). The primary circuit only is supplied with isolation valves on the flow and return. Maximum working pressure primary 16.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water (DHW) 10.0 bar. Maximum operating temperature primary 75°C. Maximum operating temperature space heating 85°C. Maximum operating temperature secondary hot water (DHW) 65°C.
Crane brass pressure test point. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Hattersley brass pressure test point. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Plastic bodied flow sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower hoses and riser rail with chromium plated brass bodies, incorporating EPDM ‘O’-rings. Maximum operating temperature 85°C.
Shower hose and handset with sliding rail and inlet kit. The inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of plastic manifold systems designed to accept interchanagble sensors (not supplied). Maximum working pressure 6.0 bar. Cold water use only.
Self-priming electric booster pump with plastic body incorporating plastic impellers with variable speed settings, and a non-return return valve (not suitable for backflow protection). Maximum working pressure 8.0 bar. Cold water use only.
Range of shower handsets (chromium plated ABS) with stainless steel strainers and a built-in approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model 28016979-00 has an adjustable flow pattern which switches between 3 patterns. Maximum operating temperature 60°C
Range of wall mounted shower outlets in various finishes. Maximum operating temperature 80°C.
Shower kit comprising of shower handset (chrome plated brass body), shower hose, 90° wall elbow, stainless-steel braided supply hose & faceplate with single lever operating members. The inlet to the shower handset incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Shower kit consisting of a shower handset (chrome plated plastic), riser rail and PVC lined multi-layered shower hose with brass connections, EPDM 'O'-rings and washers. Maximum operating temperature 60°C.
Range of shower handsets incorporating ABS bodies (chrome plated), EPDM seals and ‘O’-rings. Maximum operating temperature 65°C.
Page 3 of 564
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.