Range of Gerpex press fittings for use with Alpert multilayer (Pe-rt/Al/Pe-rt) pipe. Alpert Multilyer Composite Pipe and Press Fitting system with brass press fittings with stainless steel sleeves incorporating EPDM o-rings. 16mm to 32 mm are LBP fittings and from 40mm to 63 mm are standard fittings. Joints are achieved via TH profile press tool. Maximum working pressure: 10bar Maximum working temperature: 95°c
Range of copper and brass press-fit fittings with HNBR o-rings, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of DZR brass push fit fittings for use with copper pipe (manufactured to BS EN 1057), PB pipe (manufactured to BS7291-2) and PEX pipe (manufactured to BS7291-3). Maximum working pressures and operating temperatures: 12.5 @ 20°C, and 3.0 bar @ 92ºC.
Range of dual flush WC drop valves with an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
IR sensor activated dual flush WC siphon valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. Cold water only.
Range of stainless-steel plate heat exchangers. Maximum working pressure 10 bar. Maximum operating temperature 90°C.
‘G5 BC’ range of command centres that provide instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCS’ range of command centres that provide instant near boiling, sparkling and chilled water (all filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products incorporate a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum inlet supply pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCU60 UV’ Command centre that provides instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combinations of solenoid valves and electronic pumps to the outlets. A UV unit is incorporated on the outlet from the chilled water tank. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with black epoxy coated bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Conealed wall mounted installation set with a brass body. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Range of vertical multistage pumps with either stainless-steel bodies (“N” versions) or cast iron bodies with a black electrodeposition coating (“G” versions), stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: NKV32 & NKV45 models - 32.0 bar, NKV65 & NKV95 models - 25.0 bar. Max operating temperature: Stainless steel (“N” versions) - 100°C. Cast iron (“G” versions) - Cold water use only.
Range of vertical multistage pumps with either stainless-steel bodies (“N” versions) or cast iron bodies with a black electrodeposition coating (“G” versions), stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: FGV30, FGV45 - 32.0 bar, FGV65, FGV95 - 25.0 bar. Max operating temperature: Stainless steel (“N” versions) - 100°C. Cast iron (“G” versions) - Cold water use only.
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Range of shower handsets & overhead shower outlets with chromium plated plastic body. The inlets of the overhead shower outlets incorporate a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 60°C
Ranges of shower kits comprising of a chrome plated plastic shower handset, brass wall elbow and either stainless steel interlocked, or PVC coated, shower hoses. Shower kits with ½” (M) inlets are also supplied with a brass wall elbow which incorporate a plastic flow regulator and an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum operating temperature 60°C.
Range of shower heads with a chromium plated brass bodies, with stainless-steel strainer plastic flow regulator on the inlet. Models P42802 & P45300 have plastic bodies.
Non-metallic materials and components comply with BS6920 at 60°C

Range of hand shower outlets with chromium plated plastic bodies, stainless steel strainers and a plastic flow regulator.
Page 196 of 522
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.