Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-RT/Al/PE-RT pipes. For above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
FloFit range of push fit fittings (polybutylene body) for use with Qual-Pex Barrier Pipe, Qual-PB polybutylene barrier pipe or copper tube. Above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
‘Maincor’ range of pipe adaptors and ‘Multi-Fit’ straight connectors (brass bodies) for use with ‘Maincor PERT/Al/PERT MLC’ pipe. 12mm pipe and fittings have a maximum working pressure of 6.0 bar. 16mm & 20mm pipe and fittings have a maximum working pressure of 10.0 bar Maximum operating temperature 95°C
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
‘Epsilon Series’ polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of copper solder ring fittings for use with copper tube. For above ground use only. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of brass and copper fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 18.6 bar. Maximum operating temperature 100°C.
Range of dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush. Cold water use only
Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.
Range of stainless-steel heat exchangers. Maximum working pressure of primary Circuit 3.0 bar. Maximum working pressure of secondary Circuit 10.0 bar. Maximum operating temperature 80˚C
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.
Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve and a non-return valve (not suitable for back flow protection). Model MD1010101BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
Range of water meter manifolds with a plastic body and a spherical valve at the inlet. Models MB2012525DM & MB2010303DM incorporates two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection Model MB201010BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
Stainless steel bodied sensor with EPDM ‘O’-ring. Maximum operating temperature 90°C.
Range of flow sensors with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C
Page 18 of 205
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.