Range of dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush. Cold water use only
Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.
RINNAI range of wall mounted combination boilers.The unit incorporates a stainless-steel plate heat exchanger pressure relief valve set at 3.0 bar and an expansion vessel on the primary circuit. Maximum working pressure of primary circuit is 2.5 bar and secondary circuit is 10.0 bar. Maximum operating temperature 60˚C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.
Hydroblock unit consisting of a stainless steel heat exchanger, a pressure relief valve pre-set at 3.0 bar, diverter valve and return valve. Maximum working pressure 2.5 bar. Maximum operating temperature 90°C
Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of pump docking manifolds with plastic bodies and NBR, EPDM and FKM ‘O’-rings. Maximum working pressure 8.0 bar. Cold water use only.
Stainless steel bodied sensor with EPDM ‘O’-ring. Maximum operating temperature 90°C.
Range of flow sensors with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C
Range of wall mounted shower arms and shower handsets with brass bodies (various finishes), the inlets to the shower handsets incorporating a flow restrictor. Maximum operating temperature 60°C.
Range of vertical submersible multistage pumps. Cold water use only. Open outlet use only.
Range of central heating pumps incorporating polyether sulphone impellers, copper-tin alloy body, carbon graphite axial bearings and EPDM O-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of vertical multistage booster pumps, with stainless steel bodies and impellors (AISI304 or 316 see model). Maximum working pressure (model dependent): 4.0 bar models: BMVET(I) 32-10-1 to BMVET(I) 32-40. BMVET(I) 42-10-1 to BMVET(I) 42-20. BMVET(I) 65-10-1 to BMVET(I) 65-20-2. BMVET(I) 85-10-1 to BMVET(I) 85-10. 10.0 bar models: BMVET(I) 1-2 to BMVET(I)1-36. BMVET(I) 2-2 to BMVET(I) 2-11. BMVET(I) 3-2 to BMVET(I) 3-29. BMVET(I) 4-2 to BMVET(I) 4-10. BMVET(I) 8-2 to BMVET(I) 8-20. BMVET(I) 12-2 to BMVET(I) 12-18. BMVET(I) 16-2 t BMVET(I) 16-16. BMVET(I) 20-1 to BMVET(I) 20-17. BMVET(I) 32-50-2 to BMVET(I) 32-100. BMVET(I) 42-30-2 to BMVET(I) 42-50. BMVET(I) 65-20-1 to BMVET(I) 65-30. BMVET(I) 85-20-2 to BMVET(I) 85-30-2. 15.0 bar models: BMVET(I) 2-13 to BMVET(I) 2-26. BMVET(I) 3-31 to BMVET(I) 3-36. BMVET(I) 4-12 to BMVET(I) 4-22. BMVET(I) 32-110-2 to BMVET(I) 32-140. BMVET(I) 42-60-2 to BMVET(I) 42-130-2. BMVET(I) 65-40-2 to BMVET(I) 65-80-1. BMVET(I) 85-30-1 to BMVET(I) 85-60. Maximum operating temperature 100°C.
CM(E)(C) range of electronically operated pumps available in stainless steel, (‘EN 1.4301/AISI304’ or ‘EN 1.4401 /AISI316’) and cast iron. (CMEC models were added October 2023). The pumps are supplied with Sic-Sic mechanical shaft seals and FKM or EPDM seals. Cast iron models: Maximum working pressure 10.0 bar. Cold water use only. Stainless steel models: Maximum working pressure 16.0 bar. Maximum operating temperature 60°C for self-priming models, 99°C for all other models.
Range of submersible pumps with stainless steel bodies, impellers and shaft. The XPW range incorporates a strainer cowl on the suction end of the pump. The XPWA range features a stainless head which provides a threaded connection instead of the strainer. Cold water use only.
Dutypoint ‘VS’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels.. Maximum working pressure 10.0 bar. Cold water use only.
Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 11.03 Bar (Bypass) and 7.0 Bar (Operating).
Range of shower outlets with brass bodies (various finishes) and NBR ‘O’ rings. The inlets incorporate a flow regulator. Maximum operating temperature 60°C. Open outlet use only.
Range of shower handsets with a chromium plated plastic body. The inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Page 18 of 201
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.