Single hole, single outlet fixed combination tap assembly (chrome plated brass), incorporating a sequential headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating a quarter turn ceramic disc headworks with either single lever, dome or cross-top operating members. The spout outlets incorporate plastic aerators or flow straighteners with a stainless steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. This product also incorporates an additional spring-loaded quarter turn ceramic disc headwork with a single lever operating member for filtered cold water discharged from the spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Deck mounted two-hole, single outlet, fixed combination tap assembly (brass body, various finishes - see model), incorporating ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts and an optional stainless steel mesh washer for installation in the spout outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate either a plastic flow straightener or aerator depending on model. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
A range of wall mounted two-hole single outlet fixed combination tap assemblies with brass bodies and various finishes (see models). Incorporating a combined shut-off and manual diverter cartridge which diverts between the bath or shower outlet with various operating members (see models). The temperature is controlled independently via a thermostatic cartridge with a manual override button with dome type or single lever type operating members (See models). Both inlets incorporate stainless steel strainers and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlets incorporate plastic aerators. Maximum working pressure 10 bar, Maximum working temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks various operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic mixing valves (chrome plated brass bodies), incorporating ceramic disc diverter headworks controlling the flow from spout outlet to shower outlet using either dome or single lever operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button either dome or single lever operating members. The spout outlet incorporates a flow straightener or aerator. The inlets incorporate stainless steel strainers and approved single check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Not supplied with hose and handset. Maximum working pressure 10.0 bar Maximum operating temperature 60°C
Range of wall mounted two-hole, single outlet (fixed), combination tap assemblies incorporating brass bodies (various finishes), ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet. The spout outlets incorporate plastic aerators. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
‘Purist’ range of three hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes, see model), incorporating quarter turn ceramic disc headworks with either single lever or cross top operating members. The spout outlets incorporate a plastic aerator. The product is supplied with stainless steel braided EPDM lined flexible hose assemblies for installation between the side valves and ‘T’ connector, and a pop-up waste. Maximum working pressure 4.1 bar. Maximum operating temperature 65°C.
Range of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic aerators. Some models are supplied with lever operated pop-up wastes. Maximum working pressure 5.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted spout outlet (brass bodies - various finishes) incorporating a plastic aerator. Maximum working pressure 10 Bar. Maximum operating temperature 60°C
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Range of tap outlets with plastic bodies incorporating a filter within the body, incorporating a hollow fibre filter membrane. The inlet of the filter incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The filters are supplied with (and must be used with) a chrome plated brass adapter which incorporates a pastic flow regulator. Maximum operating temperature 60°C.
Tigris K5 (PPSU - plastic body) and M5 (DZR brass body) ranges of press-fit (U, H, TH crimp profiles) fittings with stainless steel crimp sleeves and EPDM ‘O’-rings, for use with Tigris K1 multi-layer PEX-c/AL/PE-HD pipe. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Instantor range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of brass press-fit fittings incorporating EPDM ‘O’-Rings and stainless steel crimp sleeves for use with Herz multi-layer PE-RT pipes. Maximum working pressure 10 bar. Maximum operating temperature 95°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 18 of 58
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.