Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C
‘Sonata’ range of water meters with plastic or brass/plastic bodies. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of inline water meters with blue epoxy coated cast iron body. Maximum working pressure 16.0 bar. Cold water use.
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Permanent filling devices for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. If the mains pressure is adequate and there is a drop in system pressure, then the two solenoid valves operate to allow water into the system via the transfer chamber. At all other times the normally open solenoid valve drains the transfer chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Stainless steel strainer on the inlet supply. Mikrofill 3: Maximum working pressure 5.0 Bar. Cold water use only. Mikrofill 3 Pro (72846): Maximum working pressure 9.0 Bar. Cold water use only.
Flow meter with stainless steel body. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
CMBE range of horizontal multistage centrifugal booster pumps with stainless steel bodies and impellers and EPDM ‘O’-rings. All models include an expansion vessel, non-return valve, pressure gauge and sensor on the outlet. Maximum working pressure 10.0 bar. Cold water use only.
Range of vertical multistage pumps with either stainless-steel bodies (“N” versions) or cast iron bodies with a black electrodeposition coating (“G” versions), stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: NKV32 & NKV45 models - 32.0 bar, NKV65 & NKV95 models - 25.0 bar. Max operating temperature: Stainless steel (“N” versions) - 100°C. Cast iron (“G” versions) - Cold water use only.
Range of vertical multistage pumps with either stainless-steel bodies (“N” versions) or cast iron bodies with a black electrodeposition coating (“G” versions), stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: FGV30, FGV45 - 32.0 bar, FGV65, FGV95 - 25.0 bar. Max operating temperature: Stainless steel (“N” versions) - 100°C. Cast iron (“G” versions) - Cold water use only.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of overhead showers consisting of stainless steel bodies and silicone nozzles and gaskets and shower handsets consisting of ABS (LB-2003N, LB-2003, LB-2004) or brass bodies (LB-2006 & LB-2028).
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets & overhead shower outlets with chromium plated plastic body. The inlets of the overhead shower outlets incorporate a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with (brass bodies – various finishes), incorporating EPDM `O`-rings and a plastic strainer. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Range of shower arms and elbows (brass bodies – various finishes). Maximum operating temperature: (T2064W) - 95.0°C (T2062W, T2069W & T2069SW) - 85.0°C (T2066W) - 60°C
Range of shower kits comprising of a chrome plated brass handset, shower hose and riser rail.
Non-metallic materials and components comply with BS6920 at 85°C
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Ranges of shower kits comprising of a chrome plated plastic shower handset, brass wall elbow and either stainless steel interlocked, or PVC coated, shower hoses. Shower kits with ½” (M) inlets are also supplied with a brass wall elbow which incorporate a plastic flow regulator and an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum operating temperature 60°C.
Range of shower heads with a chromium plated brass bodies, with stainless-steel strainer plastic flow regulator on the inlet. Models P42802 & P45300 have plastic bodies.
Non-metallic materials and components comply with BS6920 at 60°C

Page 161 of 443
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.