Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.
Range of temperature measurement devices with bronze bodies and EPDM o-rings. Maximum operating pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of vertical multistage pumps with either stainless-steel bodies (“N” versions) or cast iron bodies with a black electrodeposition coating (“G” versions), stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: EV30, EV45, 30VR & 45VR models - 32.0 bar, EV65, EV95, 65VR & 95VR models - 25.0 bar. Max operating temperature: Stainless steel (“N” versions) - 100°C. Cast iron (“G” versions) - Cold water use only.
Range of circulator pumps with stainless steel bodies and a plastic impeller. All models are available with a plastic (composite) rotor can, the MAGNA1 range is also available with a stainless-steel rotor can in the DN32 flanged, threaded 1½ & 2” sizes only. The MAGMA3 models have a differential pressure sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of shower outlet elbows (brass bodies - various finishes) with a shower handset holder. The product incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure - 10 Bar.
Non-metallic materials and components comply with BS6920 at 70°C
Range of overhead shower outlets (brass bodies – various finishes). The inlets incorporate a plastic flow regulator. Model 26 221 xxx and 26 465 xx0 incorporates a stainless-steel strainer, all other models incorporate a plastic strainer. Maximum operating temperature 60.0°C. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets with plastic bodies (various finishes). The inlets incorporate flow restrictors, model 24320xxx has a plastic strainer at the inlet, model 24321xxx has a stainless steel strainer at the inlet. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets with plastic bodies (various finishes) incorporating a flow regulator and stainless-steel strainer in the inlet. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets with plastic bodies. The inlet incorporates a plastic flow regulator, and the outlet incorporates a plastic aerator.
Non-metallic materials and components comply with BS6920 at 60°C
Range of multifunctional hand shower outlets with plastic bodies. The inlet is fitted with a single check valve and flow regulator, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 65°C. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 65°C
Range of single function handsets plastic bodies - various finishes. The inlet incorporates a single check valve and flow regulator, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 65°C. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 65°C
Overhead shower outlets, (brass bodies - various finishes). The inlet is fitted with a flow regulator. Maximum operating temperature 42°C. Open outlet use only.
Range of wall mounted outlet brackets, (brass bodies - various finishes).Open outlet use only.
Non-metallic materials and components comply with BS6920 at 65°C
Range of overhead shower outlets (chrome plated brass bodies) incorporating NBR ‘O’ rings.
Non-metallic materials and components comply with BS6920 at 65°C
Range of shower outlets (brass or stainless-steel bodies – various finishes) incorporating EPDM O-rings. Maximum operating temperature 60.0°C
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted shower outlet (brass body – various finishes). The product is supplied with shower hose and handset that incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower heads with chromium plated ABS bodies. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 75°C
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of draining taps with DZR brass, brass or chrome plated brass bodies. Incorporating a rising spindle headwork, EPDM or NBR seals and washers. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of draining taps with DZR brass, brass or chrome plated brass bodies. Incorporating a rising spindle headwork, EPDM or NBR seals and washers. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Page 153 of 443
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.