Range of stainless steel, copper brazed plate type heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C
Range of water meters with plastic bodies and EPDM ‘O’-rings. The inlets incorporate a plastic strainer. Maximum working pressure 10.0 bar. Cold water use only.
Air break to drain, incorporating brass bodies with a grey epoxy powder coating. Maximum operating temperature 60°C.
Impeller with plastic body for insertion into specifically dimensioned bores. Maximum operating temperature 70°C.
Wall mounted chrome plated brass elbow fitting. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Maincor Manifold having a brushed chrome plated body with 2 ,3 or 4 ports each with an isolation valve with red or blue indicators for hot and cold feeds. Supplied with a blanking plug and nut. Maximum working pressure 6.0 bar. Maximum operating temperature 75°C.
Range of in-line plastic flow regulators. The flow regulator is housed within a black plastic body incorporating a plastic strainer and an EPDM ‘O’-ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of flow through valves with brass bodies and EPDM ‘O’-rings, incorporating a spherical valve and a separate drain tap. The products are intended for connection prior to an expansion vessel. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of water monitoring systems comprising of a battery or mains operated latching solenoid valve (plastic body) and a flow sensor. The units are supplied with a hand-held controller. Maximum working pressure 10.0 bar. Cold water use only.
“Yonos PARA Z15 and Yonos PARA Z25 ” range of circulation pumps incorporating brass bodies, plastic impellers and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
A range of shower handsets with chromium plated plastic bodies and a plastic strainer and flow regulator in the inlet. Models may incorporate dark grey alternative shower plate. Maximum operating temperature 85°C.
Overhead, ceiling mounted shower outlet with chromium plated brass body (various finishes). Maximum operating temperature 60°C.
Shower handset incorporating a plastic body (chrome plated), brass wall connector (chrome plated) and shower hose. The inlet to the shower and wall connector incorporates approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of over head shower outlets incorporating brass bodies and an adjustable ball joint. The inlet incorporates a combined NBR washer and stainless-steel filter. Maximum operating temperature 60°C.
Range of wall mounted shower kit with brass bodies (various finishes) consisting of a shower rail with an overhead shower rose, incorporating a manual diverter to shower handset. Shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models AOOSCPUK and AOOSBKUK consist of just a shower handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower outlets with brass bodies (various finishes) and NBR ‘O’ rings. The inlets incorporate a flow regulator. Maximum operating temperature 60°C. Open outlet use only.
Page 14 of 564
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.