‘Hetta system’ consisting of brass bodied nickel plated, compression or press fit (‘U’ crimping profile) fittings for use with multilayer pipe PERT/AL/PERT. Maximum working pressure 10.0 Bar. Maximum working temperature 95°C.
Range of copper, bronze or DZR brass capillary solder ring fittings for use with copper pipe (manufactured to EN 1057). Maximum working pressure and operating temperatures: 8-28mm: 25.0 bar @ 30°C, 16.0 bar @ 100°C. 35-54mm: 25.0 bar @ 30°C, 16.0 bar @ 65°C and 10.0 bar @ 100°C.
Instantor range of brass compression fittings for use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
‘AquaGas M range’ of copper and brass press fit fittings with NBR ‘O’-rings for use with copper tube (manufactured to BS EN 1057). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
‘SharkBite’ range of brass push fit fittings incorporating an EPDM ‘O’-ring. For use with the following pipes: JG Speedfit Layflat Polybutylene Barrier Pipe (JG BPB pipe manufactured to BS EN 7291-2:2010), 'BPEX' Barrier Pipe (JG BPEX pipe manufactured to BS EN 7291-3:2010), Polybutylene barrier pipe (manufactured to BS EN 7291-2:2010), PEX barrier pipe (manufactured to BS EN 7291-3:2010) and Copper pipe (manufactured to BS EN1057:2006). Maximum working pressures and operating temperatures: When used with Polybutylene barrier pipes (manufactured to BS EN 7291-2:2010) and PEX barrier pipes (manufactured to BS EN 7291-3:2010): 12.5 bar, cold water use only. 6.0 bar @ 95°C. When used with copper pipe (manufactured to BS EN1057:2006): 10mm sizes: Maximum working pressure 16.0 bar. Cold water use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. 15-22mm sizes: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C. 28mm size added April 2024: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of WC flush valves with an ABS body and silicon seal. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal adjustable height overflow. Cold water use only.
Single flush WC outlet valves with an ABS plastic body (TSL721 WC99-016) operated via a mains powered infra red sensor assembly TSL721 (WC99-016A). Cold water use only.
Range of packaged plate heat exchangers comprising of stainless steel plates with EPDM gaskets. The products are supplied with twin primary circulation pumps, a secondary circulation pump, 3 port control valve and a control panel with full Mod BUS BMS connectivity. Maximum working pressure - Primary and Secondary circuits 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel, pressure relief valve set at 3.0 bar and flow regulators. The inlets to both domestic hot water and primary circuits are controlled via screwdriver operated angled spherical valve. The primary circuit can be filled via a built in CAB device, that has been verified by test (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 80°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of ancillary connections with brass bodies (various finishes). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of shower handsets with brass bodies (various finishes – see models), available with various handle finishes. Maximum working pressure: Open Outlet. Maximum operating temperature: 65.0°C.
Range of hand showers (various finishes). Maximum operating temperature 65°C
Range of shower arms, hand shower holders and wall outlet with brass bodies (various finishes). Maximum working pressure: Open outlet. Maximum operating temperature: 60°C.
Range of shower handset with chrome plated or white plastic bodies. Colour coding discs are located on the face plates of specific models. Maximum operating temperature 60°C
Range of ‘Y’- pattern strainers with cast iron bodies (blue epoxy coated) and brass plugs (EN12164), incorporating stainless steel filters (EN10088) and EPDM ‘O’-rings. Maximum operating pressure 16 bar. Maximum operating temperature 100°C
Range of pillar taps, (chrome plated brass bodies), incorporating quarter turn cermic disc headworks and single lever operating members. The products include metal back nuts. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of PVC or EPDM lined shower hoses with stainless steel outer (chrome or black finish) or PVC reinforced (chrome plated finish) outer layer. Maximum operating temperature 65°C.
Range of stainless steel braided, EPDM lined flexible hose assemblies. Models are available with a variety of end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and an approved check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 3.0 Bar Secondary: 5.5 Bar Solar: 3.0 bar Maximum operating temperature 90.0°C
Range of cased and insulated stainless steel unvented water storage heaters. The DHW circuit includes a factory fitted combined temperature and pressure relief valve set at 6.0 bar and 90˚C. The product can be supplied with two possible safety kits (inlet control groups). One includes a pressure reducing valve adjustable between 1.5-6.0 bar, (but set at 3.0 bar), a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and a pressure relief valve pre-set at 4.5 bar. The other includes a pressure reducing valve pre-set at 3.0 bar, an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection, and a pressure relief valve pre-set at 4.5 bar. The product is also supplied with an expansion vessel and a tundish. The compression connection of each inlet control group is for use with the following pipes: Both for use with copper pipe (manufactured to BS EN 1057). The inlet control group without an adjustable pressure reducing valve can also be used with PB pipe (with inserts) (manufactured to BS EN 7291-2:2010) and PEX pipe (with inserts) (manufactured to BS EN 7291-3:2010). Maximum supply pressure to inlet control group pressure reducing valve: 16.0 bar. Maximum working pressure 4.0 bar. Maximum operating temperature 99°C. Cold supply only.
Page 120 of 160
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.