Range of shower handsets, (plastic bodies – various finishes) incorporating a plastic flow regulator in the inlets.
Non-metallic materials and components comply with BS6920 at 65°C
Range of multi-function overhead shower outlets, (plastic bodies – various finishes). The inlets incorporate plastic flow restrictors and stainless-steel strainer washers.
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall and ceiling mounted shower arms with (brass bodies - various styles and finishes). Maximum operating temperature 60°C. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower outlets having plastic bodies, various finishes Maximum operating temperature 55°C
Range of shower outlet with plastic bodies (chromium plated) and plastic flow regulators. Model 27.369 supplied with a PVC multi-layered shower hose with EPDM washer and plastic strainer on inlet. Maximum working temperature 60°C.
‘Grohe Euphoria 180’ overhead shower outlet with a chromium plated brass body incorporating a plastic flow regulator. Maximum working temperature 60°C.
Range of flow sensors with brass or plastic bodies (see model). Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Two hole deck mounted, single outlet (swivel) laboratory tap incorporating a brass body (with white plastic coating) and non-rising spindle headworks with dome type operating members. The spout outlet incorporates a plastic aerator and the product is supplied with metal backnuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C
Range of pillar taps ( brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with various type operating members. The spout outlets incorporate plastic flow straighteners (except models 173601 & 173602 that have open outlets) and the products are supplied with metal back nuts. Maximum working pressure 10 bar. Maximum operating temperature 85°C.
Range of pillar taps ( brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with various type operating members. The spout are open outlets and the products are supplied with metal back nuts. Maximum working pressure 10 bar. Maximum operating temperature 85°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc (VL101 + VL101-4) or non-rising spindle headworks (all other models) with various operating members and metal backnuts. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc (VL103 + VL103-5) or non-rising spindle headworks (all other models) with various operating members and metal backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 6.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
'Hurricane' range of Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.
Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. Fitted with a Caleffi 309463 GLD temperature and pressure relief valve sat at 6 bar & 90°C, and supplied with an inlet control group consisting of in-line pressure reducing valve (Caleffi set at 3 bar) and pressure relief valve (Caleffi CWIC200055) set at 4.5 bar, and incorporates a stainless-steel mesh and an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2), expansion vessel and filling loop. Maximum working pressure 4.4 bar. Maximum operating temperature 99°C.
6300E7 series of nickel plated brass manifolds and 6300R8 series of chromium plated brass manifolds with two, three or four outlets, for use with copper pipe (manufactured to EN1057). The products incorporate a screw down isolation valve at each port. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, bar type thermostatic shower mixer (chromium plated brass) Incorporating a quarter turn headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets and shower outlet incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets also incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Wall mounted thermostatic shower valve (chrome plated brass body), incorporating a non-rising spindle headwork controlling the flow. The temperature is controlled independently with a thermostatic cartridge, both using single lever operating members. The inlets incorporate flow regulators, plastic strainers and approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower kit that consists of a shower handset, shower hose and riser rail assembly. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of thermal circulation valves with gunmetal bodies and EPDM ‘O’-rings. Models incorporate drain valves. Maximum operating pressure 16.0 bar. Maximum operating temperature 90°C.
Range of wall mounted thermostatic shower valves, (chrome plated brass bodies). Models (EG1290 & EG1209002) incorporate a non-rising spindle headwork controlling the flow with a single lever operating member. Models (EG15092 & EG1509201) incorporate quarter turn ceramic disc headworks controlling the flow with single lever operating members. The temperature on all models is controlled by a thermostatic cartridge using a cross-top type operating member. The shower outlet connection incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 Bar Maximum operating temperature 65.0°C
Non-metallic materials and components comply with BS6920 at 65°C
Range of concealed, wall mounted, thermostatic blending valves, (brass bodies, chrome trim sets). The products consist of detent headworks, two-way diverter cartridges and a thermostatic cartridges (see models). All models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Page 107 of 214
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.