Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to shower outlet and a plastic flow straightener with stainless steel mesh. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
A range of four-hole single outlet fixed combination tap assemblies with brass bodies in a variety of finishes (See models). Incorporating ¼ ceramic disc headworks with single lever operating members and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator. The shower outlet elbow incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. This product is supplied with a shower hose, shower handset and metal screw clamp type back nuts. The side valves and the spout are connected with a copper tube. Maximum working pressure 10 bar. Maximum working temperature 60 °C.
Range of brass compression fittings for use with copper pipe (manufactured to IS EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of brass compression fittings for use with copper pipe IS EN 1057. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.




Range of press fittings incorporating stainless steel bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Comisa’ range of brass bodied press-fit and threaded fittings for use with `Comisa’ (PE-RT/AL/PE-LMD) multi-layer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Boss Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of SUS316L & SUS304 stainless steel press fittings for use with stainless steel pipe manufactured to EN 10312. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press fit fittings incorporating copper (GP5 models) or bronze (GP4 models) bodies and EPDM `O`-rings, for use with copper tube to EN 1057. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
>B< Press range of stainless-steel SUS316L fittings for use with 316L stainless steel tube manufactured to EN10312. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Turbo 44R dual flush syphonic flushing apparatus with a polypropylene body and stainless steel link for use with WC flushing cisterns.
Copper brazed micro plate heat exchanger with copper and stainless-steel (316/1.4401) plates. Maximum working pressure 25.0 Bar. Maximum operating temperature 100°C
Range of plate heat exchanger with stainless steel bodies. Maximum working pressure10 bar. Maximum operating temperature 100°C.
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
(Jet) range of water meters with either ductile iron (171259 & 171279 models) or brass (all other models) blue epoxy coated bodies and EPDM rubber ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meter couplings with black plastic bodies. Maximum working pressure 16.0 bar. Cold water use only
Copper corrugated hose. Maximum working pressure 10.0 bar. Maximum working temperature 90°C.
Range of pushfit hose connectors with either plastic (white or black) or chrome plated brass bodies and EPDM ‘O’-rings. SHCV prefix models incorporate screwdriver operated servicing valves. All pushfit connections are for use with PEX pipe (manufactured to BS7291-3) and copper pipe (manufactured to EN1057). Barbed end connections are not approved for use with any hose. Chrome plated brass body models are also for use with PB pipe (manufactured to BS7291-2). Maximum working pressure 10.0 bar (servicing valve models only). Barbed end connections are open outlet use only. Cold water use only.
Page 2 of 37
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.