Range of concealed WC flushing cisterns with a side entry BS 1212-4(2016) float operated inlet valve providing a type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two button assembly for a 6 or 3 litre flush volume. The cistern incorporates a servicing valve and a stainless-steel braided EPDM lined flexible hose assembly installed prior to the inlet valve. Maximum working pressure 10.0 Bar, Cold Water use only
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.
Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.
Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.
The range of WC cisterns incorporating a BS 1212-4:2016 side entry or bottom entry float operated inlet valve providing a Type AG air gap arrangement and a flush outlet valve operated via a push button assembly for either full or reduced flush. Maximum operating pressure 10.0 bar. Cold water use only.
Range of wall hung concealed WC flushing cisterns with a BS 1212-4 float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a push button assembly. Maximum working pressure - 10 Bar. Cold water use only.
Concealed WC dual flushing cisterns with a BS 1212- 4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a manually operated dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. The inlet supply incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Range of stainless-steel press fittings for use with stainless steel pipe. Above ground use only. Maximum working pressure 16.0 Bar Maximum operating temperature 85 °C.
Range of Hyddro press fittings incorporating EPDM ‘O’-rings. For use with Hyddro (S-1-0509/10/11/12/17/13) PEX-AL-PEX pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C
Range of brass fittings with compression connections to be used with copper pipes EN 1057. For above ground use only. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.

Range of brass compression fittings for use with copper pipes and Irish copper pipe (both manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperatures: 32612, 32634, 32712 & 32734 models: 65°C. All other models: 85°C.
‘BF’ range of Brass compression fittings for use with copper pipe manufactured to EN1057 Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
‘BF’ range of Brass compression fittings for use with copper pipe manufactured to EN1057 Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of ‘M’ profile copper press fittings with EPDM ‘O’-rings for use with copper pipes (manufactured to EN 1057). Jointing is achieved via a crimping tool using a ‘M’ profile. For above and below ground use. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper pipes (manufactured to EN 1057). The 5043G series and 5002G series models incorporate an EPDM ‘O’-ring on the captive nut connection. For above and below ground use. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of brass bodied threaded fittings and a brass end feed fitting (C04069H00081A model only). The CL08069H192B4 model is chrome plated. The C04069H00081A model end feed fitting is for use with copper pipe (manufactured to EN 1057). The C04149H00191A model incorporates a plastic flow straightener. Maximum working pressure 10.0 bar, except for the C04149H00190A and C04149H00191A models which are open outlet use only. Maximum operating temperature 85°C.
Range of Y patterned strainers with a brass body. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of bronze swing gate valves with bronze bodies and discs (with a metal-to-metal seal). Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of spherical valves with DZR brass bodies, chrome plated brass balls and PTFE seats. The products incorporate a lever type operating members. Maximum working pressure 40.0 bar. Maximum operating temperature 100°C.
Page 9 of 11
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.