Range of wafer or lugged butterfly valves incorporating blue epoxy coated ductile iron bodies, EPDM seats and stainless steel or ductile iron discs (nickel plated). The products are supplied with either bare shaft or with lever or gear operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of butterfly valves incorporating blue epoxy coated ductile iron bodies and discs, EPDM seats and EPDM ‘O’-rings. Maximum working pressure: 16.0 bar. Maximum operating temperature 60°C.
Range of butterfly valves with blue epoxy coated ductile iron bodies, ductile iron or stainless steel discs with EPDM seats and a lever operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of butterfly valves incorporating blue epoxy coated ductile iron bodies and discs and an EPDM rubber seat. Maximum operating pressure 16.0 bar. Maximum operating temperature 80°C.
Range of butterfly valves incorporating blue epoxy coated ductile iron bodies, stainless-steel discs and EPDM seats. Maximum working pressure 16.0 bar. Maximum operating temperature 85ºC.
Range of combined pre-set temperature and pressure relief valves incorporating Bronze bodies, DZR brass seat and plunger, EPDM ‘O’-rings, PTFE seal and silicone diaphragm. The valves incorporate a manually operated lever easing gear. The valves are factory pre-set between 0.4 bar and 12.5 bar. Maximum operating temperature 90°C.
Concealed 2-way or 3-way ceramic disc diverter valve with shut off mechanism incorporating a brass body. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Wall mounted, concealed, two-way manual diverter valve which diverts the flow between two shower outlets. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Range of float operated valves incorporating brass bodies and EPDM seats. Maximum working pressure 14.0 bar. Maximum operating temperature 85°C.
Range of pilot operated float control valves with blue epoxy coated ductile iron bodies, NBR ‘O’-rings and gaskets. The products have flow control facility controlled via a float operated pilot valve. Supplied with auxiliary components including stainless steel pipe, spherical valves, Y-pattern strainer and a needle valve. Maximum working pressure 8.0 bar. Cold water use only.
Range of concealed flow control valves with a brass body and trim set (various finishes). The product incorporates a ceramic disc headwork with a single lever operating member divertering the flow between 2 shower outlets or a bath spout outlet. The diverter has an off position as you change between each outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted flow control valves with brass bodies (chrome plated trim sets and various operating members - see models) incorporating quarter turn ceramic disc headworks. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of flow control valves incorporating brass bodies, quarter turn ceramic disc headworks and NBR ‘O’-rings. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of spring loaded, resilient trim, non-return valves (blue epoxy coated cast iron body), with bronze bushing, stainlesss steel spring and disc, and EPDM seat. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
ART 388 Range of non return valves with brass bodies and discs, and EPDM washer. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of in-line adjustable pressure reducing valves, with DZR brass bodies and EPDM seat washers & ‘o’ rings and stainless-steel filters. Various models supplied with pressure gauge (please see model list). Maximum inlet supply pressure 16.0 bar. Outlet pressure range: 0.8-6.0 bar. Maximum operating temperature 80°C.
Range of in-line, manually adjustable pressure reducing valves with blue epoxy coated ductile iron bodies and EPDM gaskets and ‘O’-rings (all models) and an EPDM diaphragm (VRCD-M models only). VRCD models: Outlet pressure range: 1.5 - 6.0 bar or 5.0 to 12.0 bar. VRCD-M models: Outlet pressure range: 1.5 - 6.0 bar. Maximum supply pressure 16.0 bar. Cold water use only.
Range of normally open or closed solenoid valves incorporating a brass body, EPDM diaphragm and ‘O’-rings. Maximum working pressures: SCE210C034BW, SCE210C035BW: AC and DC 9.0 bar. SCE210C094BW, SCE210D095BW: AC 9.0 bar, DC 3.0 bar. Maximum operating temperature 85°C.
Range of normally closed solenoid valves with brass bodies, EPDM diaphragms and ‘O’-rings. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of latching solenoid valves with brass bodies, EPDM diaphragms and ‘O’-rings. The inlet incorporates a stainless-steel strainer. Maximum working pressure 10.0 Bar. Maximum operating temperature 70°C
Page 70 of 561
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.