Range of single or twin shower pumps with brass bodies, brass impeller supplied with flexible connection hoses that incorporate servicing valves. Maximum Working pressure 6 Bar Maximum operating temperature 65°C
Range of plastic, stainless steel or brass (see models) shower outlets comprising of a shower handset, shower rails and hose (Models: 58004-46XX and 58004-47XX), a shower handset only (Models: 53401-00XX, 56031-00XX, 53283-04XX, 56565-02XX, 56205-00XX, 56321-20XX and 56183-10XX) or an overhead shower head only (models: 51051-12XX, 54012-31XX, 54112-31XX and 54108-00XX). Models 56565-02XX and 54108-00XX incorporate stainless steel strainers. Maximum operating temperature 60.0°C, open outlet use.
A range of plastic overhead shower heads and shower handsets with various finishes. Maximum operating temperature 65.0°C Open outlet use only
Range of wall mounted shower arms with brass bodies (various finishes - see models). Maximum working temperature 70°C.
Range of overhead shower outlets with (brass bodies – various finishes) incorporating stainless-steel filter washers at the inlet. Maximum operating temperature 85°C.
Range of overhead shower outlets, (chrome plated brass bodies) incorporating flow regulators on the inlets. Model (716000) is wall mounted, all other models are ceiling mounted. Maximum operating temperature 60.0°C
Range of wall mounted shower outlets (chrome plated or white finish). Products either incorporate a filter or a dummy unit for the insertion of a filter. Models 02-092034, 02-092039, 02-803150 & 02-092031 incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Shower handset with a chrome plated ABS plastic body. Maximum operating temperature 85°C.
Range of wall mounted hose union taps brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided TPS lined flexible hose assemblies incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves Push-fit fittings for use with: Copper Pipes manufactured in accordance with BS EN 1057 PB pipes manufactured in accordance with BS 7291-2 PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure 12.0 bar. Maximum operating temperature 65°C.
‘Qualflex Excel’ range of stainless steel over braided, PEX lined flexible hoses, incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves. Push-fit fittings for use for with: Copper Pipes manufactured in accordance with BS EN 1057 Plastic PB pipes manufactured in accordance with BS 7291-2 Plastic PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure: 6.0 bar. Maximum operating temperature: 65°C.
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Range of stainless-steel or nylon braided PEX lined hoses, incorporating EPDM O-ring or gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies. Compression connections are for use with copper pipe (manufactured to BS EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of stainless steel or nylon braided EPDM lined flexible hose assemblies with various brass end connections. Compression connection to be used with copper pipe EN1057. Maximum working pressure 10 Bar. Maximum operating temperature 70°C.
Nylon and stainless-steel braided EPDM lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Range of stainless-steel expansion joints with flanged or threaded end connections. For maximum working pressure please refer to model. Maximum operating temperature 100°C.
Range of Ultraflow Air bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added January 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Wall mounted, concealed, thermostatic blending valve (brass body) with a chromium plated trim set incorporating a single sequential headwork controlling flow and temperature with a single lever operating member. The product also incorporates approved check valve cartridges, however, the complete product has not been fully tested to demonstrate they provide backflow protection. The product is supplied with a combined strainer/isolation valve for each inlet. To be used with copper pipe manufactured to EN 1057. Maximum working pressure; 10 bar. Maximum operating temperature 65°C.
Page 69 of 124
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.