Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
LT0188-B01 | Black | 1/2" BSP (F) | 9 bar | 65 °C | Mediclinics | Body | No | Solenoid | Not Applicable | Aerator |
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated stainless steel bodies). The flow is controlled by a solenoid valve that is activated via an infrared sensor, and the spout outlets incorporate plastic aerators. Maximum working pressure 8.0 Bar Maximum operating temperature 65.0°C
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlets incorporate plastic aerators. Maximum working pressure:8.0 Bar Maximum operating temperature:65 °C
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass), flow is controlled by a solenoid valve, activated via an infra-red sensor. The product is supplied with a combined TPE washer and stainless-steel strainer to be installed on the inlet to the solenoid. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass), flow is controlled by a solenoid valve, activated via an infra-red sensor. The product is supplied with a combined TPE washer and stainless-steel strainer to be installed on the inlet to the solenoid. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Range of bottom and side entry BS1212-4 (2016) compact type float operated inlet valves, for WC flushing cisterns with plastic bodies and adjustable floats and a plastic flow regulator at the inlet. Maximum operating pressure: 10 bar. Maximum operating temperature: 23°C.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
WC Cistern incorporating a side or bottom entry float operated inlet valve and a Syphon (Phantom S), Pneumatic Drop Valve (Phantom V) or Cable Operated Drop Valve (Phantom T) with full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by lever or push button. Maximum working pressure 10.0 bar. Cold water use only.
W/C suite with pan (polyester) and a concealed flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a single flush drop valve for full flush volumes of up to 6 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 Bar. Cold water use only.
Range of spherical valves with DZR brass bodies, chromium plated brass balls, PTFE seats and EPDM rubber ‘O’-ring. The products also incorporate a ‘Y’- Patterned stainless steel strainer. Compression connection to be used with copper EN1057. AI-0396A062815CR incorporates an approved single check valve cartridge, verified by test - suitable for backflow protection against fluid category 2. Maximum working pressure: 25.0 bar. Maximum operating temperature: 100°C (model AI-0396A062815CR 65°).
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated stainless steel or brass bodies, see models). The flow is controlled by a solenoid valve that is activated via an infrared sensor. Temperature is controlled independently via a single lever operating member. The spout outlets incorporate plastic aerators. Supplied with hoses that incorporate stainless steel strainers and an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 Bar Maximum operating temperature 65.0°C
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies). Flow is controlled by solenoid valves activated via an infra-red sensor and the temperature is controlled independently via single lever. The spout outlets incorporate plastic aerators. Maximum working pressure 8 Bar. Maximum operating temperature 65°C.
Range of T type thermostatic mixing valves with chrome plated DZR brass bodies. Compression and push-fit models for use with copper pipe manufactured to EN1057. Models 37.20122.015.CP,37.20122.022.CP, 37.21122.015.CP, 37.21122.022.CP, 37.21222.015.CP, 37.21222.022.CP, 37.20162.015.CP, 37.20162.022.CP have isolation valves and strainers on the inlet. Maximum working pressure 10.0 Bar. Maximum operating temperature 85.0°C.
Spring loaded, resilient trim check valve cartridge with plastic body and EPDM O-rings. For insertion into fittings with specifically sized bores. Maximum working pressure: 16 Bar. Maximum operating temperature: 85°C.
‘TankBoost’ range of cold-water storage cisterns, incorporating a float operated inlet valve. The C5 suffix models incorporate a Type ‘AB’ air gap with a meshed weir overflow (verified by test - suitable for backflow protection against Fluid Category 5). Cisterns with SUB in the model code incorporate a submersible pump and an expansion vessel. All models incorporate a screened warning pipe and dip tube. Models without a C5 suffix also incorporate a screened breather. Maximum working pressure 10.0 bar. Cold water use only.
‘TankBoost 5 bar’ range of cold-water storage cisterns, incorporating a float operated inlet valve. The C5 suffix models incorporate a Type ‘AB’ air gap with a meshed weir overflow (verified by test - suitable for backflow protection against Fluid Category 5). Cisterns with SUB in the model code incorporate a submersible pump and an expansion vessel. All models incorporate a screened warning pipe and dip tube. Models without a C5 suffix also incorporate a screened breather. Maximum working pressure 10.0 bar. Cold water use only.
Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with cross top operating members. The spout outlet incorporates a plastic aerator and a swivel nozzle. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model) with a ceramic cartridge headworks and a single lever operating member. The spout outlet incorporates a pull-out spray with plastic aerator. The pull-out spray hose connector incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
SH-QT8202W | Chrome | G1/2,female | 10 bar | 60 °C | SHANHU | body | No | Ceramic cartridge | C-plate | Aerator | |
SH-QT82022W | Chrome | G1/2,female | 10 bar | 60 °C | SHANHU | body | No | Ceramic cartridge | C-plate | Aerator | |
SH-T8182W | Chrome | G1/2,female | 10 bar | 60 °C | SHANHU | body | No | Ceramic cartridge | C-plate | Aerator | |
SH-QT8022AW | Chrome | G1/2,female | 10 bar | 60 °C | SHANHU | body | No | Ceramic cartridge | C-plate | Aerator | |
SH-QT8882CW | Chrome | G1/2,female | 10 bar | 60 °C | SHANHU | body | No | Ceramic cartridge | C-plate | Open Outlet |
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with cross top operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Page 501 of 506
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.