Wall mounted two hole, single outlet (fixed) combination tap assembly (brass body, various finishes), incorporating ceramic cartridge headwork and single lever operating member. The spout incorporates a plastic aerator. Maximum working pressure: 5.0 bar. Maximum operating temperature: 60°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate an aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure; 10 Bar Maximum operating temperature 65°C
Range of two-hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic discs headworks and single lever or dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
SuperFlow MCPA, MCMA & MCUA ranges of expansion vessels. Maximum working pressures: MCPA Series = 10.0 bar, MCMA Series = 16.0 bar, MCUA Series = 25.0 bar. Maximum operating temperature 65°C.
Filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve (suitable for back flow protection against fluid category 3) and a stainless steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Inline filter with plastic body. Maximum working pressure 5.0 bar. Cold water use only.
Range of in-line carbon block water filters and housings with polypropylene bodies. Maximum working pressure 8.0 bar. Cold water use only.
Range of brass press fittings (TH and U crimp profiles) for use with RIIFO B1 PEX/AL/PEX multilayer pipe. Maximum working pressure: 10 bar Maximum operating temperature: 95 °C
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use (sizes 12mm-54mm only. 66.7mm, 76.1mm, 88.9mm & 108mm for above ground use only) Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PCC type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Tectite Classic and Tectite Pro ranges of copper alloy push-fit fittings The Tectite Classic range is for use with copper tube (manufactured to BS EN 1057) and PEX & Polybutylene tube (manufactured to BS 7291). The fittings are supplied with plastic inserts. The Tectite Pro range is for use with copper tube (manufactured to BS EN 1057). Maximum working pressures & operating temperatures: Tectite Classic fittings with copper pipe: 6.0 bar @ 95°C, 16.0 Bar cold water use. Tectite Classic fittings with PEX & Polybutylene 6.0 bar @ 95°C, 12.0 Bar cold water use. Tectite Pro fittings (15mm - 28mm): 6.0 bar @ 95°C, 20.0 Bar cold water use. Tectite Pro fittings (32mm - 54mm): 6.0 bar @ 95°C, 16.0 Bar cold water use.
WC dual flush valves with a plastic body and incorporates an internal overflow. Cold water use only.
Range of urinal flushing mechanisms, consisting of a solenoid valve controlling the flow which is actuated via an infra-red sensor. Models are either mains or battery operated and are available in a variety of enclosure options Maximum operating pressure 8 bar. Maximum operating temperature 23°C
Range of ultrasonic water meters with brass or stainless steel bodies and plastic or stainless steel transducers. The SC-F models incorporate a spherical valve operated via a motor controlled by computer software. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line water meters with stainless steel bodies Maximum working pressure 10.0 Bar. Maximum operating temperature 50.0°C.
Range of water meters with blue epoxy power coated cast iron bodies, incorporating plastic turbines, NBR ‘O’-rings and gaskets. Maximum working pressure 16.0 bar. BS6920 50°C.
Range of water meter manifolds with plastic bodies, incorporating plastic pushfit inlets and plastic pushfit outlets. The inlets incorporate a spherical ball valve. Models MB40408256DCVDM & MB40408254DCVDM incorporate two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16 bar. Cold water use only.
Page 475 of 578
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.